Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹19.9 L+₹70,156 (3.66%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹21.9 L+₹2.7 L (14.0%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹22.0 L+₹2.8 L (14.6%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
26 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
PROVN OF CERTAIN E/M SANCTIONED WORKS UNDER GE (AF) PATHANKOT.
2020_MES_391097_1
GE/PAF-48/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹58,000
Yes
12 Dec 2020
29 Oct 2020
28 Nov 2020
29 Oct 2020
26 Nov 2020
12 Nov 2020
60 days
Amount
Supply and fixing Voltage stabilizer for automatic operation, three phase, naturally oil cooled, unbalanced type, copper wound, with digital display with overload and shortcircuit protection, High/Low voltage cut off, with Bypass arrangement & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and of capacity 60 KVA with MCCB of appropriate rating including first filling of insulation oil in stabilizer complete all as specified and directed by Eng-In-Charge.
Supply, installation, testing and commissioning of energy efficient isolation transformer , 3phase , 50 Hz, rated in put voltate 410 V±5% and output voltage stabilized at 415 V with accuracy of± 2.5%, , oil cooling type of Cap 100 KVA floor mounted indoor type copper wound with standard fitting and accessories such as oil level indicator Dehydrating silicagel breather assembly, 4 Nos iron wheels, Keys for cable box, temp gauge, top up the oil up to max limil level and installation & operating manuals etc as per IS 2026, complete all as specicified and as directed by Engineer in Charge.
Supply and fix energy efficient water heater storage type, electric supplied and installed complete incl all PVC & CP connections and having tank of capacity 25 litres, complete all as specicified and as directed by Engineer in Charge.
Supply and fix Recess mounted LED fitting with high transmittance polycarbonate diffuser 36 watt fit to 600x600 mm modular/pop/gypsum ceilling complete with including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm , complete all as specicified and as directed by Engineer in Charge.
Supply & fix Wall mounted Air Circulator fans 230 volts single phase oscillating 300 mm sweep suitable for wall mounting, complete all as specicified and as directed by Engineer in Charge.
Supply & fix exhaust fans 230 /240 volts single phase of size 450 mm sweep with louver including necessary fixing arragement, cutting of existing wall/ surface and making good surface complete all as specicified and as directed by Engineer in Charge.
Supply & fix Air Circulator fans 230 volts single phase Turbo force 600 mm sweep suitable for wall mounting including necessary fixing arrangement, complete all as specicified and as directed by Engineer in Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core , complete all as specicified and as directed by Engineer in Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 10 sq mm, 2 core, complete all as specicified and as directed by Engineer in Charge.
Supply and fix LT cable jointing kit for 1100 V grade cable for heat shrink type end joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 95 Sq mm 3.5 core, complete all as specicified and as directed by Engineer in Charge.
Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode not less than 2.25mtr below ground level with top edge of earth plate not less than 1.50 metre below normal ground level connected to galvanised earth strip of size 25 x 4mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers including brazing at joints all as directed including providing earth strip protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia medium grade with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 with adequate quantity of charcoal dust and salt all around the earth plate including all necessary earth work in any type of soil, removing surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 , complete all as specicified and as directed by Engineer in Charge. Note:-(i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .(ii) On testing after completion if the desired resistenance ( up to 5 Ohm) is not obtained the contrator shall redo the earthing without any extra cost to the department .
Earthing complete with copper earth plate elect rode 600x600x3mm thick buried directly in ground to a depth not less than 3 mtr deep below normal ground level with top edge of the earth plate not less than 2.25 mtr deep below normal ground level connected to copper strip 20x3mm size as earthing lead by means of soldering/brazing and bolts, nuts, check nuts and washers of brass, GI protection pipe light grade 40mm bore up to test point 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:2:4 type BI, RCC cover with suitable handle, earth pit filled with ground enhancing material all around earth plate up to 150 cm and filled with soil above GEM up to ground level earth work in any type of soil all as required and directed including testing on completion. Note:-(i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .(ii) On testing after completion if the desired resistenance ( up to 5 Ohm) is not obtained the contrator shall redo the earthing without any extra cost to the department .
Outdoor typoe roof covered Platform suitable for installation of above mention voltage stabilizer with brick construction in cement motor 1:4, PCC 1:3:6 type C-2 in foundation,PCC 1:2:4 type B-1 in floor,brick masonry including pre painted galvanume aluminium zinc coating GI based corrigted steet sheet 0.50 mm thick as in roof covering fixed on angle iron 50x50x6mm, earth work in any type of soil including plastering to brick masonry work in cement morta , 1:4 and painting to steel surface with two coats of syntehtic enamelled paint over a coat of primer and two coats of colour washing over a coat of white wash on plastered surface complete all as specifiedand and direrected by Engr In charge.
Supply and fix Copper strip 30 x3.15 mm complete with saddles/ insulators made out of porcelain or fiber and fixing screws for roof conductor/down conductor including proper jointing all the the joints, complete all as specicified and as directed by Engineer in Charge.
Air termination single pointed aluminium rod 12 mm dia and 300 mm long to walls/roofs/pipes with suitable clamp of MS with bolts and nuts etc required at site , complete all as specicified and as directed by Engineer in Charge.
Aluminium strip 25 x 3.15 mm complete with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all specified and as directed.
Galvanised strip 32 x 6 mm buried in ground or fixed to wall etc for loop earthing , complete all as specicified and as directed by Engineer in Charge.
GI tubing 40 mm bore light grade laid in trenches/floor/along pole for cable/earth strip protection with proper size of clamps, nuts, bolts and washer for fixing lighting conductors etc , complete all as specicified and as directed by Engineer in Charge.
Test point terminal block made of Gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw , complete all as specicified and as directed by Engineer in Charge.
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in benching including weathering slightly chamfered angles and finishing exposed surfaces even and smooth including necessary form work , complete all as specicified and as directed by Engineer in Charge.
Supplying and fixing bib taps 15mm fancy type with crutch or butterfly handle, screwed down screwed for GI pipe , complete all as specicified and as directed by Engineer in Charge.
Supplying and fixing stop valve 15mm fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe, complete all as specicified and as directed by Engineer in Charge.
Supplying and fixing GI tubing pipes galvanized, "Medium class", supplied and laid complete including fittings 15 mm (1/2") dia, complete all as specicified and as directed by Engineer in Charge.
Cutting of Existing water supply main any size upto 25 mm for taking branch connection of size 15 mm including insertion of Tee unequal , complete all as specicified and as directed by Engineer in Charge.
Point wiring for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including non metalic rigid concealed PVC conduit light grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification , complete all as specicified and as directed by Engineer in Charge.
Switch piano flush button single pole one way 15 amp 230 Volts, complete all as specicified and as directed by Engineer in Charge.
Socket out let, 6pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts , complete all as specicified and as directed by Engineer in Charge.
Point wiring in casing caping for one light point/Fan point/bell point controlled by one switch with 1.5 Sqmm PVC insulated sheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm PVC insulated sheathed copper conductor single core cable (green colour) as earth lead in and including non metallic rigid PVC casing caping with all fittings (ISI Marked) controlled by one switch including PVC sunk box of required size on the surface of wall and including 3 mm thick plastic laminated sheet, including cutting /drilling to wall and making good the disturbed surfaces to match with the existing surface, complete all as specicified and as directed by Engineer in Charge.
Point wiring for one light point/Fan point/bell point controlled by one switch with 1.5 Sqmm PVC insulated sheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm PVC insulated sheathed copper conductor single core cable (green colour) as earth lead in and including concealed non metallic rigid PVC conduit medium grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size of sheet thickness 1.6mm and as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification , complete all as specicified and as directed by Engineer in Charge.
All as per item 29 above, but for 3 pin 5 Amps socket outlet independent board, complete all as specicified and as directed by Engineer in Charge.
All as per item 29 above, but for 3 pin 5 Amps socket outlet same board, complete all as specicified and as directed by Engineer in Charge.
Supplying and fixing Switch piano flush button single pole one way 5 amps 240 volts , complete all as specicified and as directed by Engineer in Charge.
Supplying and fixing Socket 5 amps 5 pin flush type, 230 volts, complete all as specicified and as directed by Engineer in Charge.
Supplying and fixing ceiling Rose 3 terminal PVC polycarbonate isolated body , complete all as specicified and as directed by Engineer in Charge.
MCB single pole 240 volts 16 amps, with rupturing capacity 10 KA, complete all as specicified and as directed by Engineer in Charge.
LED tube light fitting along with LED Tube rod 20 W completet all fixng arrangment including 3 core PVC wire 0.75 sqmm complete all as specified and directed by Engr -In-Charge.
Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification , complete all as specicified and as directed by Engineer in Charge.
Supply and fixing MCB SPN 240 volts from 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specicified and as directed by Engineer in Charge.
Supply & fix exhaust fans AC single phase plastic body 230/ 240 V of size 250 mm sweep with louver including cutting of existing wall/ surface and making good surface , complete all as specicified and as directed by Engineer in Charge.
Supply, installation, commissioning of Watercooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 ltrs , complete all as specicified and as directed by Engineer in Charge.
Supply and fixing PVC connections 15mm size with PTMT nuts of length 450mm , complete all as specicified and as directed by Engineer in Charge.
SATISH AND CO
Vijay Kumar Contractor and Engineers
Ashoka Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .