Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹34.1 L+₹4.8 L (16.4%)Rejected-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹36.6 L+₹7.3 L (24.8%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L3 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | M/s Yash Electrical and Maintenance L2 | M/s ASPIRE ENGINEERING ENTERPRISES L1 | SHRI HARI CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified and directed by Engineer-in-charge. | 532 | Kg | 1,050 ₹5,58,600 | 850 ₹4,52,200 Lowest | 1,100 ₹5,85,200 |
| 2.00 | Repair to chillar suitable for 25 TR capacity double circuit type(02- compressor)including leakage pressure testing , leakage rectification , brizing etc.to make it fully functional with testing before install again complete all as specified and directed by Engineer-in-charge. NOTES :- Rate quoted includes taking down the chillar to outside for repair & after repair install at its orignal location. | 1 | Each Job | 15,000 ₹15,000 Lowest | 19,500 ₹19,500 | 20,000 ₹20,000 |
| 3.00 | M&L for condensor unit suitable for 12.5 TR compressor complete all as specified and directed by Engineer-in-charge. Including Gas kits, daffle plate,connecting rods,liquid port,dischagre port,service valve,service valve port , copper rods ( any size as requried of site),expender plate, condensor cell , End cover,high pressure realse valve port etc .all other equipment that are requried to functional the condensor unit complete all as specified and directed by Engineer-in-charge. Make :- voltas/bluestar/carrier/teknotherm as approved by GE. | 1 | Each Job | 20,000 ₹20,000 Lowest | 51,000 ₹51,000 | 25,000 ₹25,000 |
| 4.00 | M&L for opening end covers of condensor and chiller condenser in and including cleaning of condenser 25/50/75 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge. | 42 | Each Job | 15,000 ₹6,30,000 | 3,000 ₹1,26,000 Lowest | 16,000 ₹6,72,000 |
| 5.00 | Supply and replacing of compressor oil 25/50/75 TR for compressor as per site complete all as specified and directed by Engineer-in-charge. | 150 | Ltrs | 120 ₹18,000 Lowest | 200 ₹30,000 | 120 ₹18,000 Lowest |
| 6.00 | M&L for servicing servicing of AHU of 50/25/75 TR AC plant including cleaning of filters by cleaning with chemical solution as required at site complete all as specified and directed by Engineer-in-charge. | 12 | Each Job | 1,000 ₹12,000 Lowest | 1,800 ₹21,600 | 1,000 ₹12,000 Lowest |
| 7.00 | Disconnecting the electrical connection & taking down the burnt out motor of capacity 10 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by Engineer-in-charge. | 4 | Each Job | 5,000 ₹20,000 Lowest | 6,500 ₹26,000 | 5,000 ₹20,000 Lowest |
| 8.00 | All as per tem No. 7.00 here-in-before above but of capacity 7.5HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts | 8 | Each Job | 4,500 ₹36,000 Lowest | 5,500 ₹44,000 | 4,500 ₹36,000 Lowest |
| 9.00 | All as per tem No. 7.00 here-in-before above but 5 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts | 10 | Each Job | 4,000 ₹40,000 Lowest | 5,000 ₹50,000 | 4,000 ₹40,000 Lowest |
| 10.00 | All as per tem No. 7.00 here-in-before above but of capacity 3 HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts | 4 | Each Job | 3,000 ₹12,000 Lowest | 3,500 ₹14,000 | 3,000 ₹12,000 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
REPAIR AND MAINTENANCE OF AC PLANTS UPPER AND LOWER AT CERTAIN UNITS AND MISC REPAIR WORKS UNDER THE JURISDICTION OF GE (A) JAISALMER. (CPP SERIAL No.105)
2026_MES_747792_1
84337/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY JAISALMER
₹60,000
Yes
27 Feb 2026
9 Jan 2026
31 Jan 2026
9 Jan 2026
29 Jan 2026
24 Jan 2026
9 Jan 2026 - 16 Jan 2026
Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified and directed by Engineer-in-charge.
Repair to chillar suitable for 25 TR capacity double circuit type(02- compressor)including leakage pressure testing , leakage rectification , brizing etc.to make it fully functional with testing before install again complete all as specified and directed by Engineer-in-charge. NOTES :- Rate quoted includes taking down the chillar to outside for repair & after repair install at its orignal location.
M&L for condensor unit suitable for 12.5 TR compressor complete all as specified and directed by Engineer-in-charge. Including Gas kits, daffle plate,connecting rods,liquid port,dischagre port,service valve,service valve port , copper rods ( any size as requried of site),expender plate, condensor cell , End cover,high pressure realse valve port etc .all other equipment that are requried to functional the condensor unit complete all as specified and directed by Engineer-in-charge. Make :- voltas/bluestar/carrier/teknotherm as approved by GE.
M&L for opening end covers of condensor and chiller condenser in and including cleaning of condenser 25/50/75 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge.
Supply and replacing of compressor oil 25/50/75 TR for compressor as per site complete all as specified and directed by Engineer-in-charge.
M&L for servicing servicing of AHU of 50/25/75 TR AC plant including cleaning of filters by cleaning with chemical solution as required at site complete all as specified and directed by Engineer-in-charge.
Disconnecting the electrical connection & taking down the burnt out motor of capacity 10 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by Engineer-in-charge.
All as per tem No. 7.00 here-in-before above but of capacity 7.5HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts
All as per tem No. 7.00 here-in-before above but 5 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts
All as per tem No. 7.00 here-in-before above but of capacity 3 HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts
All as per tem No. 7.00 here-in-before above but 2 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts
S&F in repair V Belt A-47 type Poly F-plus complete all as specified and directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE.
S&F in repair V Belt B-122 type Poly F-plus complete all as specified and directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE.
S&F in repair V Belt A 1200 A-46 Poly F-plus type complete all as specified and directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE.
S&F in repair V Belt A-24 type Poly F-plus complete all as specified and directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE.
S&F in repair V Belt B-113 type Poly F-plus complete all as specified and directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE.
S&F in repair LP/HP cut out suitable for 25 TR unit of ac plant complete all as specified and directed by Engineer-in-charge. Make - As per avaliable at site location
S&F in repair LP/HP cut out suitable for 38 TR unit complete all as specified and directed by Engineer-in-charge. Make - As per avaliable at site location
Repair/replacement Moduling Thermostate suitable for 50 TR plant AHU complete all as specified and directed by Engineer-in-charge.
S&F in repair of over load protector relay of existing range & size upto 7.5 HP at plant room complete all as specified and directed by Engineer-in-charge.
S&F in repair of over load protector relay of existing range & size upto 10 HP at plant room complete all as specified and directed by Engineer-in-charge.
S&F in repair expansion valve suitable for 25 TR unit capacity AC plant complete all as specified and directed by Engineer-in-charge. Make - danfoss or equivalent make as approved by GE.
S&F in repair expansion valve suitable for 38 TR capacity AC plant complete all as specified and directed by Engineer-in-charge. Make - danfoss or equivalent make as approved by GE.
S&F in repair, Suction/water/discharge pressure gauge round type made out of brass with cyphon for chillar line & condensor line of ac plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, temperature thermometer for chillar line & condensor line of AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, compressor suction/discharge valve of 25 TR unit complete all as specified and directed by Engineer-in-charge.
Repair to hot water generator (63 KW -capacity),415V, 3-phase of 75 TR ac plant. make it fully operational with replacement /repair of damged /worn out parts complete Including testing to make fully functional complete all as specified and directed by Engineer-in-charge.
S&F sprinkler of 3'' and 4- way with pvc pipe 04 Nos and clamps nut bolt and all accessories complate for AC plant of 50 TR capacity of cooling tower complete all as specified and directed by Engineer-in-charge.
S&F in repair, water pressure valve made out of brass for AC plant 50 TR capacity complete all as specified and directed by Engineer-in-charge.
S&F in repair, gun metal globe or gate valve of 25 mm with iron wheel head screwed both ends for iron pipe, including all fittings complete all as specified and directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve of 20 mm with iron wheel head screwed both ends for iron pipe, including all fittings complete all as specified and directed by Engineer-in-charge.
S&F in reapir Add on auxillary contact block of suitable for 32 amp contactor complete all as specified and directed by Engineer-in-charge. Make - BCH/L&T or equivalent make as approved by GE.
S&F in repair, butterfly valve of 80mm dia pressure class water type with iron handle complete all as specified and directed by Engineer-in-charge.
S&F in repair butterfly valve of 100 mm dia pressure class water type with iron handle complete all as specified and directed by Engineer-in-charge.
S&F in reapir balancing valve of 80 mm including all fittings like-flanges etc. complete all as specified and directed by Engineer-in-charge.
S&F in repair digital ammeter complete all as specified and directed by Engineer-in-charge.
S&F in repair Contactor 50 Amp 3pole for complete all as specified and directed by Engineer-in-charge.
S&F in repair Contactor 32 Amp 3pole complete all as specified and directed by Engineer-in-charge.
S&F in repair Contactor 25 Amp 3pole complete all as specified and directed by Engineer-in-charge.
S&F in repair Contactor 80 Amp 3-pole complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB TP 6 to 32 Amp, , 415V, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB TP 63 Amp 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB TP 40 Amp 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB SP 6 to 32 Amp,240V, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 400 Amp 36 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 200 Amps 36 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 250 Amps 36 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 125 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair indicator lamp LED type complete all as specified and directed by Engineer-in-charge.
S&F in repair single phase preventor having five protection complete all as specified and directed by Engineer-in-charge.
S&F in repair push button switch 220 Volts, 15 Amps complete all as specified and directed by Engineer-in-charge.
S&F replacement/ renewal of fins of cooling tower of AC plant and taking out old worn out finns complete in all respect complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control 25 TR unit carefully without damaging any other electronic control system & S& F new PCB assembly alongwith display and software update cotrol, testing and cmmissioning complete all as specified and directed by Engineer-in-charge. Make - bluestar/voltas or equivalent make as approved by GE.
Dismantling and taking down unserviceable PCB assembly control 38 TR unit carefully without damaging any other electronic control system & S& F new PCB assembly alongwith display and software update cotrol, testing and cmmissioning complete all as specified and directed by Engineer-in-charge. Make - bluestar/voltas or equivalent make as approved by GE.
Dismantling and taking down unserviceable PCB assembly control AC plant 14 TR carefully without damaging any other electronic control system and repair of U/serviceable battery,LED, transistors, capacitors, inductors, diodes, switches and software update control making it all functional in all respect and refixing testing complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control 12.5 TR unit carefully without damaging any other electronic control system & S& F new PCB assembly alongwith display and software update cotrol, testing and cmmissioning complete all as specified and directed by Engineer-in-charge. Make - bluestar/voltas or equivalent make as approved by GE.
S&F in repair air release valve suitable for chiller water pipe line of 80mm complete all as specified and directed by Engineer-in-charge.
S&F in repair drier filter for compressor of 12.5 TR complete all as specified and directed by Engineer-in-charge. Make - danfoss or equivalent make as approved by GE.
S&F in repair water flow switch for 50TR AC plant as per site complete all as specified and directed by Engineer-in-charge. Make - Honeywell or equivalent make as approved by GE.
S&F in repair temperature sensor for 50TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair liquid line valve for 50 TR AC plant complete all as specified and directed by Engineer-in-charge.
M&L for repair/cleaning of cooling tower of 75 TR ac plant including welding work and proper check & rectify of axial flow of fan with adjustable angle and motor, replacement of unserviceable/ torn nut complete all as specified and directed by Engineer-in-charge.
M&L for repair/cleaning of cooling tower of 25 TR ac plant including welding work and proper check & rectify of axial flow of fan with adjustable angle and motor, replacement of unserviceable/ torn nut complete all as specified and directed by Engineer-in-charge.
M&L for repair/cleaning of cooling tower of 12.5 TR ac plant including welding work and proper check & rectify of axial flow of fan with adjustable angle and motor, replacement of unserviceable/ torn nut complete all as specified and directed by Engineer-in-charge.
M&L for repair/cleaning of cooling tower of 50 TR ac plant including welding work and proper check & rectify of axial flow of fan with adjustable angle and motor, replacement of unserviceable/ torn nut complete all as specified and directed by Engineer-in-charge.
Cleaning of Y-strainer of 80 mm dia size by opening the cover including complete fittings, nut-bolts etc complete all as specified and directed by Engineer-in-charge.
M&L for repair and making good PCC plinth/base for motor- Pump set (5 HP-02nos ) by using 1:2:4 concrete and fixing with suitable MS channel base plate with all fitting acessories, nuts & bolts etc, incl necessary plastering works (L,B,H all are as existing) and complete all as specified and directed by Engineer-in-charge.
M&L for repair and making good PCC plinth/base for motor- Pump set (7.5 HP-2nos ) by using 1:2:4 concrete and fixing with suitable MS channel base plate with all fitting acessories, nuts & bolts etc, incl necessary plastering works (L,B,H all are as existing) and complete all as specified and directed by Engineer-in-charge.
S&F in repair copper tube of 5/8 dia complete all as specified and directed by Engineer-in-charge.
Supplying laying and fixing with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc jointing and testing LT XLPE insulated galvanized steel wire armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor of cross sectional area 6.0 Sqmm 2 Core complete all as specified and directed by Engineer-in-charge.
Material and labour for taking down the 10/7.5 HP Capacity pump from base plate after disconnecting the all pipe lines and transporting (to & fro) workshop for repair, dismantling the complete pump and reassembling/re-fixing in original position, testing & commissioning complete all as specified and directed by Engineer-in-charge with the replacement of the following items :-.
Coupling/mechnical seal
Coupling rubber
All as per item No. 73.00 here-in-before above but 5 HP complete all as specified and directed by Engineer-in-charge.
Coupling/mechnical seal
Coupling rubber
All as per item No. 73.00 here-in-before above but 3/2 HP complete all as specified and directed by Engineer-in-charge.
Coupling seal
Coupling rubber
Bearings for pump
M&L in replacement of pipe galvanised iron 'Medium' class fixing on wall, floor etc complete including fitting of size 25 mm complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 76.00 here-in-before above but of size 20 mm
Disconnecting and taking down unserviceable service tank (PVC 1000ltr cap ) and supply & fixing new service tank of cap 1000 ltrs with all fittings complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking down unserviceable service tank (PVC 2000ltr cap ) and supply & fixing new service tank of cap 2000 ltrs with all fittings complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking down unserviceable service tank (PVC 500ltr cap ) and supply & fixing new service tank of cap 500 ltrs with all fittings complete insulation same as mentioned in item no- 97 complete all as specified and directed by Engineer-in-charge.
M&L in repair chilled water pipeline MS pipe 50 mm dia, C- CLASS including all types of fittings such as tee, bend ,flanges, elbow etc testing & commissioning complete all as specified and directed by Engineer-in-charge.
M&L in repair chilled water pipeline MS pipe 80 mm dia, C- CLASS including all types of fittings such as tee ,bend ,flanges ,elbow etc. testing & commissioning complete all as specified and directed by Engineer-in-charge.
S&F in repair change over switch of 63 amp , 430volt, three phase complete all as specified and directed by Engineer-in-charge. Note :- As per exisiting make & type
S&F in repair Float valve ( 20mm size )with all fittings complete all as specified and directed by Engineer-in-charge.
Taking out of damged cable tray & S&F new cable tray same as existing at site complete all as specified and directed by Engineer-in-charge.
S&F in repair air filter for AHU of 25 TR capacity ac plant complete all as specified and directed by Engineer-in-charge. Make :- As per exisiting make
M&L for painting to all equipments of central AC plants including piping,condensor,cable tray, motor -pump set etc .complete all as specified and directed by Engineer-in-charge.
S&F in Repair insulation of 19 mm thick for Chillar/Evaporator unit with closed cell elastrometric nitrile rubber of suitable density , thermal conductivity not excceeding 0.035W/MOK class 1 , fire performance to pass class 1 as per BS476 part 6 & class 0 as per BS 476 part 7 & use recommended adhesive /SR fevicol 505 grade . the insulation should covered with treated woven glass fiber reinforced covering (markine white clothing )& finished with 26 G alumnimum cladding for outdoor complete all as specified and directed by Engineer-in-charge.
M&L for taking out damged /worn out chillar water piping insulation and S&F For insulation of 32mm thick for exposed chillar water pipeline of suitable size up to 100/80mm mm dia with closed cell elastrometric nitrile rubber of suitable density , thermal conductivity not excceeding 0.035W/MOK class 1 , fire performance to pass class 1 as per BS476 part 6 & class 0 as per BS 476 part 7 & use recommended adhesive /SR fevicol 505 grade . the insulation should covered with treated woven glass fiber reinforced covering (markine white clothing )& finished with 26 G alumnimum cladding for outdoor complete all as specified and directed by Engineer-in-charge.
Disconnecting and isolating the semi sealed compressor of AC plant of 12.5 TR capacity from its installed position by placing dummy plates to suction and discharge valves, opening of the compressor, removing of the internal parts, cleaning of all parts thoroughly, overhauling of the compressor, replacing of worn out parts such as crank shaft, pistons, CR assembly, suction reeds, discharge reeds, DV stopper, ORP valve, oil filter screen, piston rings and gasket set, including rewinding of compressor and reassembling of the all internal parts after replacing the worn-out parts, refixing back, removing of the dummy plate, oil charging and checking oil pressure, vacuumising and leak testing and testing the compressor complete all as specified and directed by Engineer-in-charge. Note : Compressor oil shall be deemed to be included in the rate quoted. However refrigerant will be measured and paid separately under the relevant item.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
TENDER_84337.pdf
Tender Documents • 3.36 MB
BOQ_837415.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .