Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | L1 | Accepted-AOC Lowest and Reasonable. | |
| 2 | L2₹16.8 L+₹1.5 L (9.52%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹17.4 L+₹2.1 L (13.8%)Rejected-Finance D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹18.9 L+₹3.6 L (23.7%)Rejected-Finance 85 D GHOSH PARA ROAD BARRAKPORE KOLKATA PIN 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
3 Dec 2020, 6:00 pmClosed
GE DIPATOLI
GARRISON ENGINEER MES DIPATOLI MIL STN P.O. - HOTWAR RANCHI (JHARKHAND) 835217
REPAIR / MAINT OF LT CABLE, FEEDER PILLAR BOX AND E/M INSTALLATION AT DIPATOLI MIL STATION
2020_MES_390524_1
8000/1628/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DIPATOLI
CLASS E CATEGORY b(i)
7 documents required · 7 mandatory
₹500
Yes
GE DIPATOLI
₹30,000
Yes
16 Jan 2021
5 Nov 2020
5 Dec 2020
5 Nov 2020
3 Dec 2020
19 Nov 2020
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr for foundation for shafts, well, cesspits, mainholes ect in any type of soil for foundation and getting out and levelling of bottom surface to required level complete all as specified and as directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class 'B' laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Relaying the old bricks of any any size and description retrieved complete all as specified and directed.
Supply and fix in replacement of 40 mm bore GI pipe light grade including fittings, fixed on pole /trenches/wall/road crossing etc complete with and including suitable size of MS clamp, nut, bolt etc complete all as specified and as directed.
Description all as per Srl items No.8 here-in-before but of size 50 mm bore complete all as specified and as directed.
Description all as per Srl items No.8 here-in-before but of size 80 mm bore complete all as specified and as directed.
Taking down old unserviceable/burn out LT cable of size 3.5 core 240 sqmm from the pole/wall/trenches after disconnecting of all electric connections etc complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 185 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 150 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 120 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 95 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 70 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 50 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 35 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 25 sqmm x 4 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 16 sqmm x 4 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 16 sqmm x 2 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 10 sqmm x 4 core complete all as specified and as directed.
Description all as per Srl items No.11 here-in-before but of size 10 sqmm x 2 core complete all as specified and as directed. Note for Srl Item No. 11 to 23:- Excavation and earth work will be measured and paid separately.
Relaying the LT cable of size 240 sqmm x 3.5 core retrieved from taking down complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 185 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 150 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 120 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 95 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 70 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 50 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 35 sqmm x 3.5 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 25 sqmm x 4 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 16 sqmm x 4 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 16 sqmm x 2 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 10 sqmm x 4 core complete all as specified and directed at site.
Description all as per Srl items No. 24 here-in-before but of size 10 sqmm x 2 core complete all as specified and directed at site.
Supply, laying, jointing, testing and commissioning XLPE insulated, armoured, heavy duty, LT UG cable with aluminium conductor, 1100 volts grade cross sectional area 240 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and as directed. Note for srl item No. 37 to 49:- Excavation, earth work and cable protection shall be measured and paid seperately.
Description all as per Srl items No. 37 here-in-before but of size 185 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 150 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 120 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 95 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 70 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 50 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 35 sqmm x 3.5 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 25 sqmm x 4 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 16 sqmm x 4 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 16 sqmm x 2 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 10 sqmm x 4 core complete all as specified and as directed.
Description all as per Srl items No. 37 here-in-before but of size 10 sqmm x 2 core complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation mass concrete and filling complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggaregate as in kerbs/coping /bed plates and like including weathering, slightly rounded or chamfered complete with necessary use and waste of form work complete all as specified and as directed at site.
M&L for PCC (1:3:6) type C1 using 20 mm graded stone aggaregate in kerbs/coping /bed plates and like including weathering, slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed.
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed at site.
S& F in replacement of Danger Notice Plate of 1.6 mm thick mild steel sheet, vitrous, enamelled white, with letters, figures and conventional skull and bones in single red color and fixed with M.S.Clamps, bolts and nuts of approved size (20x15) cm for LT complete all as specified and as directed.
Supply and fix junction box, of size (250X200)mm x 105mm polycarbonate body with impremgated rubber gasket, duly weather proof and vermine proof with IP-65 protection with loop in and loop out cable terminal suitable for cable size 16 Sqmm 4 core including complete with fixing arrangement using (50mm x 50mm x6mm) angle iron -02Nos, 30 cm in ground and 30 cm above ground level with PCC in 30 cm in ground and suitable size nut, bolt etc complete all as specified and as directed. Make:- Sintex or equivalent IS marked.
M &L for GI earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than (0.90x 0.90)m x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size (32 x 6) mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts & washers , testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing strip with Main LT Panel/Transformer, main control board etc, filling with charcoal dust, and common salt, including necessary excavation and earth work in any type of soil, perforated watering pipe of size 15 mm dia, funnel with wire mesh, earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1, (450 x450)mm x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
Re-stringing the ACSR conductor section wise incl binding with 14 SWG/Al binding wire disconnection of service wire/cable and re-connection complete all as specified and directed.
Taking down/dismantling LT PCC/steel tubular poles, studs, insulator including V clamp, cross arms, earth wire support etc complete all as specified and directed.
M&L steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 Meters long) complete all as specified and as directed at site. Note:- Excavation, earth work & PCC work shall be measured and paid separately.
M&L for cutting of tree branches including cutting of trunk branches & stacking of serviceable material and disposal of unserviceable materials to a distance not exc 50 mtr & clearing site all as specified and directed at site. Note:- Span up to 50 mtr length shall be measured and paid as one span.
M&L for galvanised iron 4.0 mm dia for continuous earth on poles longitudinal/across brace of candles pole guarding etc complete all as specified and as directed.
S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and as directed.
S&F aluminium strip (25x3)mm mm by replacing unserviceble strip with and including necessary clamps nut bolts complete all as specified and as directed. Note:- Strip shall be fixed on porcelain insulators with vertical insulators.
M&L for painting of LT poles 9 mtr above GL with cement based paint with two coats including making good to receive the paint including base paint strips with synthetic enamel paint of approved colour complete all as specified and as directed.
M&L for painting of framed structure gates, fencing/ chequred plates with two coats of aluminium paint by scrapping old paint including preparation of surface for receiving paint complete all as specified and as directed.
Associated Engineers
M/s Kundu Enterprises
Vp sanjiv
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .