Annual Maintenance of Mini water Supply in Sindhanur Municipal Limit.
DMA/2026-27/WS/WORK_INDENT57814
DMA/2026-27/WS/WORK_INDENT57814
Open
Water supply/sewage lines
Electronic Documents, First(One Cover)
DMA City Municipal Council Sindhanuru
5 documents required · 5 mandatory
₹1,040
₹98,000
30 Apr 2026
30 Apr 2026
15 May 2026
Annual Maintenance of Mini water Supply in Sindhanur Municipal Limit.
Rewinding of submersible pumpset with copper winding wires of appropriate guage, as per specifications and / or directions of the departmental officials, including all materials, labour, equipment and...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of submersible pump sets, requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and tes...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Replace the components of motor parts of submersible pump sets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labou...
Cleaning of borewells including yield testing of borewell either using slow or fast rigs for not more than 2 hours at the final depth with a minimum working of 2 hours continuously with air compressor...
Re-drilling of filled-up borewell, including yield test at final depth.
Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includin...
Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includin...
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments 1x3x2.5 ...
Supply and delivery at site of brand new best make gate valve as per IS
778/1984 with ISI Mark and as per its latest amendments Size 50 mm
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog ...
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog ...
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well cap...
Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets
Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof ...
Rewinding of monoblock motor with copper insulaton wire suitable
gauge as per ISI specification with all necessary materials and labour,tools
and equipments with guarantee period of not less than 12 m...
Rewinding of monoblock motor with copper insulaton wire suitable
gauge as per ISI specification with all necessary materials and labour,tools
and equipments with guarantee period of not less than 12 m...
Rewinding of monoblock motor with copper insulaton wire suitable
gauge as per ISI specification with all necessary materials and labour,tools
and equipments with guarantee period of not less than 12 m...
Rewinding of monoblock motor with copper insulaton wire suitable
gauge as per ISI specification with all necessary materials and labour,tools
and equipments with guarantee period of not less than 12 m...
Providing Ball bearing as per ISI specifiction with guarantee period of
not less than 12 months Bearing cost for 10HP
Providing Ball bearing as per ISI specifiction with guarantee period of
not less than 12 months Bearing cost for 30HP
Providing Ball bearing as per ISI specifiction with guarantee period of
not less than 12 months Bearing cost for 60HP
Providing Ball bearing as per ISI specifiction with guarantee period of
not less than 12 months Bearing cost for 100HP
Providing thrust bearing as per ISI specifiction with guarantee period
of not less than 12 months Bearing cost for 30 HP
Providing thrust bearing as per ISI specifiction with guarantee period
of not less than 12 months Bearing cost for 60 HP
Providing thrust bearing as per ISI specifiction with guarantee period
of not less than 12 months Bearing cost for 100 HP
Providing thrust bearing as per ISI specifiction with guarantee period
of not less than 12 months Bearing cost for 100 HP
Providing terminal plate as per ISI specifiction with guarantee period
of not less than 12 months terminal plate 15 to 30
Providing terminal plate as per ISI specifiction with guarantee period
of not less than 12 months terminal plate 40 to 60
Providing terminal plate as per ISI specifiction with guarantee period
of not less than 12 months terminal plate 80 to 120
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump Phosphorous bronze bearing bush for 30 HP to 40 HP
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump Phosphorous bronze bearing bush for 50 HP to 60 HP
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump Phosphorous bronze bearing bush for 80 HP to 100 HP
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee
period of not less than 12 months V-T PUMP IMPELLER AND NECK RING IMPELLER AND NECK RING for 30 HP to 40 HP
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee
period of not less than 12 months V-T PUMP IMPELLER AND NECK RING IMPELLER AND NECK RING for 50 HP to 60 HP
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee
period of not less than 12 months V-T PUMP IMPELLER AND NECK RING IMPELLER AND NECK RING for 80 HP to 100 HP
ALL TYPES OF JACK WELL V-T PUMP DETAILS as per ISI specifiction with
guarantee period of not less than 12 months -For Pump dismentaling
and refitting after attending repairs. 60 HP to 120 HP
For Bottom body bush fitting 60 HP to 120 HP
For Pump open & fitting at work shop 60 HP to 120 HP
For Shaft steel welding and making bearing sheet Each 25 HP to 100 HP
For Joint rope of 1kg 25 HP to 100 HP
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW-2 Minici Water Supply -57814.doc
Tender Document • 2.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .