| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.0 L+₹2.0 L (18.3%)Rejected-Finance H 50 C SHAKARPUR DELHI 110092 | SHAHDARA | DELHI | 110092 | L2 | Rejected-Finance Rejected |
Tender Value
₹14.1 L
EMD Value
₹29,650
Closing Date
2 Jan 2023, 10:00 amClosed
Atul Bhardwaj
Hauz Khas
Re-development of Aya Nagar (Street light poles with LED fittings) Redevelopment of Aya Nagar johad (P/o Street light poles with LED fittings)General Electrical work. Sub Head- Provision of Electrical work.
2022_SDMC_139383_2
EEE/SZ/2022-23/38
Open Tender
Electrical Works
Works
60 days
South Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹29,650
25 Jan 2024
23 Dec 2022
2 Jan 2023
23 Dec 2022
2 Jan 2023
23 Dec 2022
Amount
Laying and Jointing PVC Pipe. Heading
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a)3 x 2.5 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &, 15/16 amps moduler socket outlet and 15/16 amps moduler switch. Connection etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps moduler &, 15/16 amps moduler socket outlet and 5/6 amps moduler switch. Connection etc as required.(for light plugs to be used in non residential buildings)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 amps
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Installation of exhaust fan in the existing opening ,including making good the damage, connection, testing ,commissioning etc.as required Up to 450 mm sweep
S.I.T.C of LED Tube type Luminaire 20W rating complete with Polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable Conforming to IS 7098/1988 of following Sizes (a) 2 X6 SQmm
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable Conforming to IS 7098/1988 of following Sizes (a) 2 X 10 SQmm
Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB &‘C’&39; characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.Logo/Name of manufacturer shall be embossed on the pole.Galvanization as per relevant IS .7.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm(L) & times; 600 mm wide and 1200 mm deep i/cx excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -1160 mm long (approx.) - 8 nos( with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts 20 mm dia, 750 mm long,J type i/c 2 nos. template anchor plates of size 225mm×' 225 mm & times; 3 mm and providing DCW HDPE for cable entry and exit as required for 7m and 8 mtr pole.
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of 4 nos foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c,4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
providing and laying of HDPE pipe of 40 mm outer dia with PN 4 rating by hand moling /manual method Confirming to IS 4984.592
Fabrication supplyiing and fixing B-class Galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
Fabrication supplyiing and fixing B-class Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
Supply,installation,testing & commissioning of single phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtr. suction and delivery 25X25 mm.
Supply of 250 mm(10 inch) sweep 1200 rpm exhaust fan fresh Air Type complete with shutter blades etc as required.
Providing and fixing FRP Fencing at Electrical Installation with necessory concreting for grounding vertical post, hardware. Accessories, fitting, etc of 2000 mm height above the ground and 300 mm, grounding in ground minimum along with fencing 1 number of FRP gate with necessary hardware, acessories, brass/ stainless steel metal lock fitting etc of suitable lenght width & amp'height, width & amp;height ie I number gate as per site requirement.
Iluminators And Circuiteers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .