Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 CrAccepted-AOC | ₹34.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹35.3 CrRejected-Finance | ₹35.3 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹35.9 CrRejected-Finance | ₹35.9 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹23.5 Cr
EMD Value
₹33.5 L
Closing Date
15 Apr 2021, 1:00 pmClosed
Executive Engineer-II
MPHC Complex, Imphal
Construction of Infrastructure of Churachandpur Medical Collage (SH Prefabricated Academic Block, Hospital Ward Extension Boys Hostel Girls Hostel)
2021_MPHCL_1343_1
06/EE-II/MPHC/2020-21
Open Tender
Composite Works
120 days
As per tender documents
As per tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd.
₹33.5 L
25 Jan 2022
31 Mar 2021
15 Apr 2021
31 Mar 2021
15 Apr 2021
5 Apr 2021
1 Apr 2021 - 12 Apr 2021
Amount
(A)Academic block
DISMANTLING
Dismantling sheet roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of unserviceable materials within 50 m lead.(a) G.I. sheet roofing
Dismantling ballies in posts, purlins or rafters including stacking the materrials within 50 m. lead.
Dismantling doors, windows and clerestory windows ventilators etc.(wood or steel) shutters including choukhats, architraves, holdfasts and other attachment etc. complete and stacking them within 50 m lead.(a) Not exceeding 3 sqm in area.
Demolition of brick work above G.L. upto floor two level including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead.
Demolition of brick work below G.L. upto 1 m depth including stacking of serviceable materials within 50 m lead and disposal of unserviceable materials within 50 m lead(a) In cement mortar
Demolition above G.L.upto floor two level including disposal of unserviceable materials with 50 m lead(i)Unreinforced cement concrete upto 15 cm. thickness.
Dismantling textile covering in ceiling/walling including frames and cover fillets stacking of serviceable materials and disposal of unserviceable materials within 50 m lead.
Demolition above G.L. upto floor two level including disposal of unserviceable materials with 50 m lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. work.(a) R.C.C. work.
Demolition below G.L. upto 1 m.depth including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. work.(a)R.C.C. Work
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
(b) Lift above 1.5 m upto 3.0 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with naturally occuring sand gravel under floors including watering ramming, consolidating and dressing complete with a lead of 50m (i) within 15 Km
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(c)Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
(d ) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4Kanhaighat coarse sand)
(i) above plinth level upto 1st floor level.
(ii) Above 1st floor level upto 2nd floor level
(iii) Above 2nd floor level upto 3rd floor level
(iv) Above 3rd floor level upto 4th floor level
MS & SS STEEL WORK
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint .
(i) In beams & joists with connecting plates or angles cleats as in main & cross beams, hip & jack rafters, purlins connected to common rafter and the like.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
P/F M.S. round holdig down or anchor bolts with nuts & washer plates complete.
Providing & fixing in position collapsible steel shutters with vertical channels 20 mm X 10 mm X 2 mm & braced with flat iron diagonals 20 mm X 5 mm sizes with top & bottom rails of T iron 40 mm X 40 mm X 6 mm with 38 mm dia steel pullets complete with bolts & nuts, looking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
FLOORING
Providing and laying rectified(Non-skid) Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Kanaighat Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Granite Stone slab flooring over 20 mm ( Average) thick base of cement mortar 1: 6 laid and jointed with grey cement slurry including rubbing and polishing complte with(i)Granite slab of 20mm thick(a)Jade Black ( 60 cmX 120cm)
Providing and Laying vitrified floor tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, laid on 20 thick cement mortar 1:4 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged) (i)Branded
Providing and Laying vitrified tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, in Skirting , raiser of steps over 12 thick bed of cement mortar 1:3 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged)(i)Branded
Providing & fixing M.S. holder bat clamps embedded in & i/c cement concrete blocks 112.5 mm X 112.5 mm of 1:2:4 mix (1 cement:2 coarse sand:4 hard stone ballast 20 mm & down gauge).a)150 mm diameter
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
SH:- ALUMINIUM WORK
Providing and fixing aluminium works for doors windows, Ventilators and partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately):For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade ( 12 mm thick WPC Panelling).
Providing and Fixing galzing in aluminium door windows ventilator shutters and partition etc with EPDM rubber/neprene gasket etc .complete as per the architectural drawing and the directions of enigineer in charge (a)With flot glass panes of 4mm thickness
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade (6mm thick Aluminium grill).
Providing and fixing AL sliding bolts Bright finished or black enamelled with nut & screws etc.complete (a) 300 x 16 mm.
Providing & fixing Al. Tower bolts (barrel type) with screws etc. complete.(a) 250 x 10 mm
Providing & fixing Al. handles with necessary screws etc. complete. (a) 125 mm
ROOFING & CEILING
Trapzoidal Pre painted profile sheet roofing of appoved brand DYNA Roof or Equivalent with selt driling screws of 68mm long Xloy coated screw with PVC washer & caps Compete,Excluding the coat of purlins & trussesPre painted Galvalume Sheet (PPGL) i) Profile sheet 0.50mm/4.2kgs/Sqm
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter &
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing 16mm Thk.“Wooden slat‟‟ FR grades, 2430x131 made of exterior grade MDF backed with acoustical fleece providing sound absorption of 0.88 NRC as per ISO 354.to be installed with 15mm aluminium profile conforms to aluminium alloy 6063-t 6.Temper as per bs:1474-1987 and G.I lock in clips on the back of tongue and groove system. Thedensity perpanel is 750-800 kg/m3.the panels come with tongue & groove for seamless patterns, 4-28mm groove and visible panel. These slats are made from acoustical fibre board with linear perforations for excellent uniformity. The perpendicular holes are available on the back of panel which are covered by black acoustical fleece. Achieves sound reduction of 0.88NRC. To be installed on G.I studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick, 1000 gsm absorb wool tested as per fire retardant astmd 635-1991 insulation and is 15061-2002 forexcellent results. „Wood fibre cement composite‟ tiles made of wood fibre 1mm width cement omposites 25 mm thick with an option of colours as per the choice of the architect/ person in charge of size 600x1200 mm. Has excellent noise absorption of 1 NRC as per ISO: 354-1985 and ASTM 423-90 a, density 400 kg/ m3, meets stringent fire ratings ASTM d- 876 and bs:476, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% RH at 60 deg. Celcius (140 Fahrenheit) for 15 days= no deterioration. Conforms to EN 131682001 and are ROHS ompliance. To be installed with aluminium h profile on G.I studs 00x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibrationmanagement and long life with a backing of 50mm thick, 1000 gsm absorb wooltested asper fire retardant astmd 635-1991/insulation and is 15061-2002 for xcellent results. APPROX SURFACE AREA FOR 2 NO.S LECTURE HALL = 400sqm.
MISCELLANEOUS WORK
Providimg and fixing false ceiling at all height including providing and fixing of frame work made of special sections,power pressed from M.S. Sheets and galavanized with zinc coating of 120gms/sqm ( both side inclusive) as per is 277 and consisting of angle cleats of size 25mm wode X 1.6 mm thick with flanges of 27mm flanges of 20mm amd 30mm long , the perimeter of ceiling fixed to wall /Partition with the help of rawl plugs at 450mm centerr,with 25mm long dry wall screws @ 230mm interbal, including fixing of gypus board to(a)Fully Perforated Gypsum board of size 1200 X2400 X12.4mm Having approx.15% perforated area with perforation size and pattern as approved by engineer Incharge
Supply & fixing of 50 mm thick panels of size 2400/2700/3000 mm length and 600 mm wide having Tongue & Groove joint system for walls, partitions and floor. The panels are made of two fibre reinforced cement sheets enclosing a light weight aerated concrete core composed of cement & binders. The fibre reinforced cement sheets are confirming to IS 13000-1990 or IS-14862-2000 Classification Type A(with upto amendment took place). These panels need to meet transverse load & modulus of rupture requirements as per ASTM-E-72:98 & IS 2380 Part4. The panels are laid on G.I floor channel of 1 mm thick and 14x50/75x25 mm and ceiling channel of size 38x50/75x38 mm. The rate should include hard ware, Labor, transport, lifting charges and wastages etc. as a complete item of work excluding finising, fitting etc and partions laid as per specification, drawing & as directed by engineer incharge.
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Painting on wall with ( two coats ) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
MISCELLANEOUS WORK
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem :Kanhaighat 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
Water Supply and Sanitary Installation
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:3:6(1 cem :3 Kanhaighat coarse sand:: 6 graded stone aggrt. 40mm nominal size).
(c) 1: 2 : 4 (1 cem : 2 Coarse sand : 4 graded stone aggrt. 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 Kanhaighat graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending,binding and placing in position complete
(b) TMT bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain
( c )Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(f)Edges of slab and breaks in floor not exceeding 1m in depth
2nd class (local first class) brick work in foundation upto plinth in cement mortar 1:4(1 Cem: 4Kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand:) in superstructure (a)above plinth.
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required (a):White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush complete including painting of fitting and brackkets cutting and making good the wall and floors wherever required. one urinal basin with 5 litre white PVC automatic flushing cistern
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type SONA).
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
(b) 75 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 25mm diameter
Providing and fixing grating of approved quality for Nahni trap Stainless steel, 125mm nominal diameter with 25mm waste hole
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 2000 litres net capacity storage tanks
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
Electrical Component
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X16mm2+1X16mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Supply and drawing (following pair) 0.5mm2 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as reqd.
Fitting Accessories
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS15W LED 8575 complete with connection as rqd. (Havell's)
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
SITC Aesthetically designed 2X2 LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination PLUTOSURFACE2X2PLS42WLED857S.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
S/F LED bulk head liminaries deep down annodised Al. Body, heat resistant prismatic glass cover.
MS & DB Boards
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 250 amp. TPN on load changeover switch - 1 No.
2. 250 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 6 Nos.
P/F following RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd.
(a) 63 amp. Four pole RCCB 100mA/300mA.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing
P/F of lightning conductor finial made of 25mm dia. 900mm long copper tube having 5-prong at top with 85mm dia. 3mm thich copper plate including holes etc. complete as required.
Fixing of lightning conductor finial 25mm dia. 900mm long copper/GI tube having 5-prong at top with 85mm dia. 3mm thick base plate i/c holes etc. as reqd.
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for vertical)
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for horizontal)
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
Fire Extinguisher & Fire Detector System
SECTION-A
INTERNAL HYDRANT
Providing and fixing black steel pipes for internal hydrant & sprinkler piping to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections required including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.
100mm dia NB
80mm dia NB
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing standard short size stainless steel branch pipe with gunmetal nozzle 16mm dia outlet with standard instantaneous type 63mm dia coupling (ISI marked)
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.
Supplying, installation,testing and commissioning of stainless steel office plates and having 6mm nominal thickness, upto 200mm outer dia. And internal dia. Suitable to reduce pressure to between 3.2 to 3.5 kg/sq.mm complete as required.
Providing & fixing stainless steel fire brigade inlet with 63mm dia instantaneous type inlet and 150mm dia flanged outlet with built in check valve for fir brigade connection to underground tanks and fire risers (I.S 904-1965) tested for 20kg/cm2 pressure complete in all respects with companion flanges, nuts, bolts, gaskets, etc. (a) Two way
Providing and fixing gunmetal single acting air release valve with screwed inlet 25mm dia as per IS 12992 reted for 20kg/sq.cm.
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanfes as per table "E" complete in all respects.
100mm dia with lever
Providing and fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
100mm dia
SECTION-B
INTERNAL SPRINKLER
Supplying and fixing M.S. pipe to I.S. 1239 (Heavy Class) complete with all fittings like, unions, coupling, bends, elbows, fees, offsets, reducers, flanges, as per table "E" etc. to complete the work as per the requirement at site including painting with one coat of primer after surface preparation and two coats of thick synthetic enamel paint, cutting and making good the walla good complete. Note: The pipe will be hung from the ceiling using GI fully threaded rods and GI Hanger rings only.
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Providing & fixing 15mm dia chromium plated brass sprinkler head with quarztzoid bulb and set to operate at 68 Dec C complete in all respects.
Pendent type
Ceiling Rossette
Flexi Drop-UL Listed (upto 1000mm)
Supplying & fixing vane type waterflow switxh suitable for installation on 50mm to 150mm dia line for a service pressure upto 20kg/sq.cm to be connected to Fire Alarm Syatem.
SECTION-C
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
100mm dia
SECTION-D
PUMPS AND ACCESSORIES
Supply, installation,testing and commissioning of electrically driven high pressure centrifugal fire hydrant/sprinkler pump, suitable for automatic operation consicting of the following:
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and ccoupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 2250 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Squirrel cage induction motor, TEFC type suitable for operation on 415volts, 3 phase 50Hz A.C supply for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (upto date) with flexible coupling and coupling guard, complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
f. The rate includes interconnecting cables, foundations & foundation bolts.
Supply, installation,testing and commissioning of deisel engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date.
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 2250 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory and shall be gotten approved by the Local Fire Authority).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Radiator cooled diesel engine of speed 1800 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation fo 8 hours continuous working. The tank shall be fitted with magnetic oil lever indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade) 2 nos. x 12 volts battery, flexible coupling, coupling guard & exhaust pipe connection complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
Supply, installation,testing and commissioning of jockey pump (pressurisation pump) comprising of the following:
The pump head and base shall be CI GG20 construction and impellers, diffusers, shaff sleeve, seal bush & pump shaff shall be in $$ 304 material capable of delivering 2250 LPM.The pump shall be provided with mechanical seal. The system shall be complete with necessary pressure guage with gun metal shut off cock on delivery side. (The pump should be tested and assembled for bench mark at factory)
b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as reqd.
c. Common base plate for (a) and (b) from M.S. Channel for required size.
d. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
For pump defined above & of duty as follows:
Hydrant & Sprinkler System
Flow: 280 LPM
Head: 70 mts
Providing, fixing, testing and commissioning of epoxy coated MS body precharged pressure/air vessel 300 ltr capacity having a pressure rating of 1.6 bar for pressurization of hydrant/sprinkler system complete in all respect with valves to operate as per operating sequences incliding 25mm dia drain valve, air release valve duly painted from inside and outside complete as required.
SITC of Pressure guage
Supply, installation,testing and commissioning of 100mm dia bourden type, stainless steel dial type glycerine fillede pressure guage including brass isolation valve and pipe having caliberation of 0-16 kg/cm2.
Providing & fixing welded pipe suction header upto 6 mtr. Long with two inlet. All outlets and ends with flanged connections, blank, flanges as required including painting with one coat of red oxide primer and two or more coats of synthetic enamel paint to give an even shade.
200mmx6mm thick-150mmx2 inlet; 80mmx1 inlet; 150mmx1 outlet
Providing and fixing black steel pipes to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections, all type of welded or screwed joint as per specifications and making connections required, including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more coats of synthetic enamel paint of first grade as per IS specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.(Make: Tata/Jindal/Nezone)
200mm dia NB
150mm dia NB
100mm dia NB
80mm dia NB
65mm dia NB
Providing & fixing cast iron Foot valves including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion as per table
150mm dia
80mm dia
Providing & fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion flanges as per table "E" complete
150mm dia
65mm dia
Providing & fixing MS structural work fabricated from standard sections, eg., MS rounds, angels, channels, including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by the engineer-in-charge including cutting and making good the walls and floors (for Pipe Support Structures & Cable Tray)
Providing & fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanges as per table "E" complete in all respects.
80mm dia with lever
65mm dia with lever
150mm dia with lever
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
SITC of Pressure Switches
ELECTRICAL INSTALLATION FOR FIRE PROTECTION SYSTEM
MCC for fire fightingequipments
a. 1 No. 400 amps 4 pole mechanical interlocked incoming MCCB complete with the following:
iii. Phase indicating lamp shall be protected by 2 amp SP MCB 1 set
b. Aluminium bus bar sleeves type rated at 500 amps for three phase & neutral phase bus bar shall have maximum current density of 1 amp/sq.cm and the neutral bus bar of not less than 50% capacity.
Outgoing:
b. 1 No. 32 amps TPN MCCB, 7.5 KW direct online starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall contain CT operated ammeter of 0-30 amps & indicating lamp with MCBs for 'ON'/'OFF' TRIP status of pump motor.
c. Providing and fixing 1 No. auto start panel activated with pressure switch for diesel engine complete with all accessories, batteries, battery charger of suitable rating, MCB timers, push buttons, microprocessor based alarm annunclator, wiring and cabling including connection to diesel engine complete as required ready for working.
d. Necessary cable alleys space for spare switchs, internal wiring and copper earthing of all equipment shall also be included. All switch gears/control gears shall be motor duty rating.
Note: All MCCB's to be suitable for motor duty shall be of 36KA breaking capacity.
Provision shall be made for providing potential free contacts to all pumps starters for connection for building automation system.
MCC as described above
SECTION-E
HAND APPLIANCES
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
Providing and fixing at approved location approved make 4 nos., for buckets of 24 guage galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black nd gold including stand fabricated out to sheet metal (16 guage) shade, platform and associated civil works, painting etc. as approved by the department.
F. FIRE ALARM
Supply, intallation, testing and commissioning of Conventional optical smoke detector with base complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of Conventional Hooter complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of PVC Body Manual Call Point (non-glass type) complete in all respect Morley, Apollo, System Sensor, Agni
Supply, intallation, testing and commissioning of Conventional Fire Alarm Panel System Sensor, Ravel, Agni
Microprocessor controller and LCD Display
Supplying, drawing, connecting, testing & commissioning of 2 corex1.5 sq.mm multi stranded copper conductor, pvc insulated PVC sheathed, aluminium myler tape shielded armoured cable suitable for Fire Alarm System. Havells, Polycab, Crystal, Gloster.
Air Conditions
S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X4mm2+1X4mm2 earth wire
(b) 2X16mm2+1X16mm2 earth wire
P/F TP & N dos-connector fuse switch unit inside the existing cubic panel board with ISI marks HRC fuses i/c drilling holes in the cubic panel board making connection as reqd.
(a)100 amp. TP & N
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with Cu. Plate 600mmx600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as reqd.
Extra for using salt and charcoal for G.I. or Cu. Plate earth electrode as reqd.
P/F 4.mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Lift /Elevator
SITC of Automatic gearless elevator/lift of 16(sixteen) passengers capable of load about 1020 kgs @ 1mt/sec. with car size 1700mmx1530mm deep, car enclosure, entrance, machine room, power operated automatic door operation including necessary assembling at site make Omega Elevators.
(B) HOSPITAL WARD EXTENSION
DISMANTLING
Dismantling sheet roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of unserviceable materials within 50 m lead.(a) G.I. sheet roofing
Dismantling ballies in posts, purlins or rafters including stacking the materrials within 50 m. lead.
Dismantling doors, windows and clerestory windows ventilators etc.(wood or steel) shutters including choukhats, architraves, holdfasts and other attachment etc. complete and stacking them within 50 m lead.(a) Not exceeding 3 sqm in area.
Demolition of brick work above G.L. upto floor two level including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead.
Demolition of brick work below G.L. upto 1 m depth including stacking of serviceable materials within 50 m lead and disposal of unserviceable materials within 50 m lead(a) In cement mortar
Demolition above G.L.upto floor two level including disposal of unserviceable materials with 50 m lead(i)Unreinforced cement concrete upto 15 cm. thickness.
Dismantling textile covering in ceiling/walling including frames and cover fillets stacking of serviceable materials and disposal of unserviceable materials within 50 m lead.
Demolition above G.L. upto floor two level including disposal of unserviceable materials with 50 m lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. work.(a) R.C.C. work.
Demolition below G.L. upto 1 m.depth including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. work.(a)R.C.C. Work
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
(b) Lift above 1.5 m upto 3.0 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete with a lead of 50m
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(c)Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4Kanhaighat coarse sand)
(i) above plinth level upto 1st floor level.
(ii) Above 1st floor level upto 2nd floor level
(iii) Above 2nd floor level upto 3rd floor level
MS & SS STEEL WORK
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint .
(i) In beams & joists with connecting plates or angles cleats as in main & cross beams, hip & jack rafters, purlins connected to common rafter and the like.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
P/F M.S. round holdig down or anchor bolts with nuts & washer plates complete.
Providing & fixing in position collapsible steel shutters with vertical channels 20 mm X 10 mm X 2 mm & braced with flat iron diagonals 20 mm X 5 mm sizes with top & bottom rails of T iron 40 mm X 40 mm X 6 mm with 38 mm dia steel pullets complete with bolts & nuts, looking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
FLOORING
Providing and laying rectified(Non-skid) Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Kanaighat Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Granite Stone slab flooring over 20 mm ( Average) thick base of cement mortar 1: 6 laid and jointed with grey cement slurry including rubbing and polishing complte with(i)Granite slab of 20mm thick(a)Jade Black ( 60 cmX 120cm)
Providing and Laying vitrified floor tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, laid on 20 thick cement mortar 1:4 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged) (i)Branded
Providing and Laying vitrified tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, in Skirting , raiser of steps over 12 thick bed of cement mortar 1:3 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged)(i)Branded
Providing & fixing on wall face G.I. rain water pipe i/c filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2 (1 cement:2 fine sand). A) 150 mm diameter
Providing & fixing M.S. holder bat clamps embedded in & i/c cement concrete blocks 112.5 mm X 112.5 mm of 1:2:4 mix (1 cement:2 coarse sand:4 hard stone ballast 20 mm & down gauge).a)150 mm diameter
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
ALUMINIUM WORK
Providing and fixing aluminium works for doors windos, Ventilators and partions woth extruded built up standard tuubular sections/appropriate Z sections and other sections of approved make confirming to IS 733 and IS 1285 Fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up gaps at juctions,at top bottom and side with requried EPDM rubber/Neoprene/pannlling,CP brass/Stainless Steel Screws all complete as per architectural drawing and the directions of Engineer in Charge( Glazing & Paneeling to be paid separately)(a)Anodised Aluminium
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade ( 12 mm thick WPC Panelling).
Providing and Fixing galzing in aluminium door windows ventilator shutters and partition etc with EPDM rubber/neprene gasket etc .complete as per the architectural drawing and the directions of enigineer in charge (a)With flot glass panes of 4mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item): (i) With float glass panes of 4.0 mm thickness
Providing and fixing AL sliding bolts Bright finished or black enamelled with nut & screws etc.complete (a) 300 x 16 mm.
Providing & fixing Al. Tower bolts (barrel type) with screws etc. complete.(a) 250 x 10 mm
Providing & fixing Al. handles with necessary screws etc. complete. (a) 125 mm
ROOFING & CEILING
Trapzoidal Pre painted profile sheet roofing of appoved brand DYNA Roof or Equivalent with selt driling screws of 68mm long Xloy coated screw with PVC washer & caps Compete,Excluding the coat of purlins & trussesPre painted Galvalume Sheet (PPGL) i) Profile sheet 0.50mm/4.2kgs/Sqm
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter &
Providing and fixing 16mm Thk.“Wooden slat‟‟ FR grades, 2430x131 made of exterior grade MDF backed with acoustical fleece providing sound absorption of 0.88 NRC as per ISO 354.to be installed with 15mm aluminium profile conforms to aluminium alloy 6063-t 6.Temper as per bs:1474-1987 and G.I lock in clips on the back of tongue and groove system. Thedensity perpanel is 750-800 kg/m3.the panels come with tongue & groove for seamless patterns, 4-28mm groove and visible panel. These slats are made from acoustical fibre board with linear perforations for excellent uniformity. The perpendicular holes are available on the back of panel which are covered by black acoustical fleece. Achieves sound reduction of 0.88NRC. To be installed on G.I studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120gsm zinc coating specially designed for acoustic vibration management and long life with a backing of 50mm thick, 1000 gsm absorb wool tested as per fire retardant astmd 635-1991 insulation and is 15061-2002 forexcellent results. „Wood fibre cement composite‟ tiles made of wood fibre 1mm width cement omposites 25 mm thick with an option of colours as per the choice of the architect/ person in charge of size 600x1200 mm. Has excellent noise absorption of 1 NRC as per ISO: 354-1985 and ASTM 423-90 a, density 400 kg/ m3, meets stringent fire ratings ASTM d- 876 and bs:476, weather resistance as per is 3308, thermal insulation as per is:3346-1980 with relative humidity of 90% RH at 60 deg. Celcius (140 Fahrenheit) for 15 days= no deterioration. Conforms to EN 131682001 and are ROHS ompliance. To be installed with aluminium h profile on G.I studs 00x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120gsm zinc coating specially designed for acoustic vibrationmanagement and long life with a backing of 50mm thick, 1000 gsm absorb wooltested asper fire retardant astmd 635-1991/insulation and is 15061-2002 for xcellent results. APPROX SURFACE AREA FOR 2 NO.S LECTURE HALL = 400sqm.
SH:- MISCELLANEOUS WORK
Providimg and fixing false ceiling at all height including providing and fixing of frame work made of special sections,power pressed from M.S. Sheets and galavanized with zinc coating of 120gms/sqm ( both side inclusive) as per is 277 and consisting of angle cleats of size 25mm wode X 1.6 mm thick with flanges of 27mm flanges of 20mm amd 30mm long , the perimeter of ceiling fixed to wall /Partition with the help of rawl plugs at 450mm centerr,with 25mm long dry wall screws @ 230mm interbal, including fixing of gypus board to(a)Fully Perforated Gypsum board of size 1200 X2400 X12.4mm Having approx.15% perforated area with perforation size and pattern as approved by engineer Incharge
Supply & fixing of 50 mm thick panels of size 2400/2700/3000 mm length and 600 mm wide having Tongue & Groove joint system for walls, partitions and floor. The panels are made of two fibre reinforced cement sheets enclosing a light weight aerated concrete core composed of cement & binders. The fibre reinforced cement sheets are confirming to IS 13000-1990 or IS-14862-2000 Classification Type A(with upto amendment took place). These panels need to meet transverse load & modulus of rupture requirements as per ASTM-E-72:98 & IS 2380 Part4. The panels are laid on G.I floor channel of 1 mm thick and 14x50/75x25 mm and ceiling channel of size 38x50/75x38 mm. The rate should include hard ware, Labor, transport, lifting charges and wastages etc. as a complete item of work excluding finising, fitting etc and partions laid as per specification, drawing & as directed by engineer incharge.
SH : FINISHING
12mm cement plaster 1:4(1 cement:4 kanhaighat coarse sand)
15 mm cement plaster 1:4(1 cement:4 kanhaighat coarse sand)
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand)finished with a floating coat of neat cement.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Painting on wall with ( two coats ) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
MISCELLANEOUS WORK
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
Water Supply and Sanitary Installation
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:3:6(1 cem :3 Kanhaighat coarse sand:: 6 graded stone aggrt. 40mm nominal size).
(c) 1: 2 : 4 (1 cem : 2 Coarse sand : 4 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing an
Reinforcement for R.C.C.work including bending,binding and placing in position complete
(b) TMT bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain
( c )Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(f)Edges of slab and breaks in floor not exceeding 1m in depth
2nd class (local first class) brick work in foundation and plinth level in cement mortar 1:4(1 Cem:4C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand:) in superstructure (a)above plinth.
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required (a):White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush complete including painting of fitting and brackkets cutting and making good the wall and floors wherever required. one urinal basin with 5 litre white PVC automatic flushing cistern
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type SONA).
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
(b) 75 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 25mm diameter
Providing and fixing grating of approved quality for Nahni trap Stainless steel, 125mm nominal diameter with 25mm waste hole
Providing and fixing telephonic shower rose with one meter flexible tube, Dimple/Round/Fancy.
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 2000 litres net capacity storage tanks
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
IEI WORK
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X10mm2+1X10mm2 earth wire
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X16mm2+1X16mm2 earth wire
P/L 50mm2 4-core pvc ins.(heavy duty)Cu. cond. armoured cable of 1.IKV grade of size not exceedng 25mm2 but not exceeding 120 sqmm direct in ground i/c excavation,sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS15W LED 8575 complete with connection as rqd. (Havell's)
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
S/F 12W LED bulb.
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of four way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 200 amp. TPN on load changeover switch - 1 No.
2. 200 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'C' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
P/F of lightning conductor finial made of 25mm dia. 900mm long copper tube having 5-prong at top with 85mm dia. 3mm thich copper plate including holes etc. complete as required.
Fixing of lightning conductor finial 25mm dia. 900mm long copper/GI tube having 5-prong at top with 85mm dia. 3mm thick base plate i/c holes etc. as reqd.
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for vertical)
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for horizontal)
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
Fire Extinguisher & Fire Detector System
SECTION-A
INTERNAL HYDRANT
Providing and fixing black steel pipes for internal hydrant & sprinkler piping to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections required including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.
100mm dia NB
80mm dia NB
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing standard short size stainless steel branch pipe with gunmetal nozzle 16mm dia outlet with standard instantaneous type 63mm dia coupling (ISI marked)
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.
Supplying, installation,testing and commissioning of stainless steel office plates and having 6mm nominal thickness, upto 200mm outer dia. And internal dia. Suitable to reduce pressure to between 3.2 to 3.5 kg/sq.mm complete as required.
Providing & fixing stainless steel fire brigade inlet with 63mm dia instantaneous type inlet and 150mm dia flanged outlet with built in check valve for fir brigade connection to underground tanks and fire risers (I.S 904-1965) tested for 20kg/cm2 pressure complete in all respects with companion flanges, nuts, bolts, gaskets, etc. (a) Two way
Providing and fixing gunmetal single acting air release valve with screwed inlet 25mm dia as per IS 12992 reted for 20kg/sq.cm.
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanfes as per table "E" complete in all respects.
100mm dia with lever
Providing and fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
100mm dia
SECTION-B
INTERNAL SPRINKLER
Supplying and fixing M.S. pipe to I.S. 1239 (Heavy Class) complete with all fittings like, unions, coupling, bends, elbows, fees, offsets, reducers, flanges, as per table "E" etc. to complete the work as per the requirement at site including painting with one coat of primer after surface preparation and two coats of thick synthetic enamel paint, cutting and making good the walla good complete. Note: The pipe will be hung from the ceiling using GI fully threaded rods and GI Hanger rings only.
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Providing & fixing 15mm dia chromium plated brass sprinkler head with quarztzoid bulb and set to operate at 68 Dec C complete in all respects.
Pendent type
Ceiling Rossette
Flexi Drop-UL Listed (upto 1000mm)
Supplying & fixing vane type waterflow switxh suitable for installation on 50mm to 150mm dia line for a service pressure upto 20kg/sq.cm to be connected to Fire Alarm Syatem.
SECTION-C
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
100mm dia
SECTION-D
PUMPS AND ACCESSORIES
Supply, installation,testing and commissioning of electrically driven high pressure centrifugal fire hydrant/sprinkler pump, suitable for automatic operation consicting of the following:
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and ccoupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 2250 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Squirrel cage induction motor, TEFC type suitable for operation on 415volts, 3 phase 50Hz A.C supply for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (upto date) with flexible coupling and coupling guard, complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
f. The rate includes interconnecting cables, foundations & foundation bolts.
Supply, installation,testing and commissioning of deisel engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date.
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 2250 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory and shall be gotten approved by the Local Fire Authority).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Radiator cooled diesel engine of speed 1800 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation fo 8 hours continuous working. The tank shall be fitted with magnetic oil lever indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade) 2 nos. x 12 volts battery, flexible coupling, coupling guard & exhaust pipe connection complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
Supply, installation,testing and commissioning of jockey pump (pressurisation pump) comprising of the following:
The pump head and base shall be CI GG20 construction and impellers, diffusers, shaff sleeve, seal bush & pump shaff shall be in $$ 304 material capable of delivering 2250 LPM.The pump shall be provided with mechanical seal. The system shall be complete with necessary pressure guage with gun metal shut off cock on delivery side. (The pump should be tested and assembled for bench mark at factory)
b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as reqd.
c. Common base plate for (a) and (b) from M.S. Channel for required size.
d. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
For pump defined above & of duty as follows:
Hydrant & Sprinkler System
Flow: 280 LPM
Head: 70 mts
Providing, fixing, testing and commissioning of epoxy coated MS body precharged pressure/air vessel 300 ltr capacity having a pressure rating of 1.6 bar for pressurization of hydrant/sprinkler system complete in all respect with valves to operate as per operating sequences incliding 25mm dia drain valve, air release valve duly painted from inside and outside complete as required.
SITC of Pressure guage
Supply, installation,testing and commissioning of 100mm dia bourden type, stainless steel dial type glycerine fillede pressure guage including brass isolation valve and pipe having caliberation of 0-16 kg/cm2.
Providing & fixing welded pipe suction header upto 6 mtr. Long with two inlet. All outlets and ends with flanged connections, blank, flanges as required including painting with one coat of red oxide primer and two or more coats of synthetic enamel paint to give an even shade.
200mmx6mm thick-150mmx2 inlet; 80mmx1 inlet; 150mmx1 outlet
Providing and fixing black steel pipes to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections, all type of welded or screwed joint as per specifications and making connections required, including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more coats of synthetic enamel paint of first grade as per IS specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.(Make: Tata/Jindal/Nezone)
200mm dia NB
150mm dia NB
100mm dia NB
80mm dia NB
65mm dia NB
Providing & fixing cast iron Foot valves including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion as per table
150mm dia
80mm dia
Providing & fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion flanges as per table "E" complete
150mm dia
65mm dia
Providing & fixing MS structural work fabricated from standard sections, eg., MS rounds, angels, channels, including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by the engineer-in-charge including cutting and making good the walls and floors (for Pipe Support Structures & Cable Tray)
Providing & fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanges as per table "E" complete in all respects.
80mm dia with lever
65mm dia with lever
150mm dia with lever
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
SITC of Pressure Switches
ELECTRICAL INSTALLATION FOR FIRE PROTECTION SYSTEM
MCC for fire fightingequipments
a. 1 No. 400 amps 4 pole mechanical interlocked incoming MCCB complete with the following:
iii. Phase indicating lamp shall be protected by 2 amp SP MCB 1 set
b. Aluminium bus bar sleeves type rated at 500 amps for three phase & neutral phase bus bar shall have maximum current density of 1 amp/sq.cm and the neutral bus bar of not less than 50% capacity.
Outgoing:
b. 1 No. 32 amps TPN MCCB, 7.5 KW direct online starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall contain CT operated ammeter of 0-30 amps & indicating lamp with MCBs for 'ON'/'OFF' TRIP status of pump motor.
c. Providing and fixing 1 No. auto start panel activated with pressure switch for diesel engine complete with all accessories, batteries, battery charger of suitable rating, MCB timers, push buttons, microprocessor based alarm annunclator, wiring and cabling including connection to diesel engine complete as required ready for working.
d. Necessary cable alleys space for spare switchs, internal wiring and copper earthing of all equipment shall also be included. All switch gears/control gears shall be motor duty rating.
Note: All MCCB's to be suitable for motor duty shall be of 36KA breaking capacity.
Provision shall be made for providing potential free contacts to all pumps starters for connection for building automation system.
MCC as described above
SECTION-E
HAND APPLIANCES
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
Providing and fixing at approved location approved make 4 nos., for buckets of 24 guage galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black nd gold including stand fabricated out to sheet metal (16 guage) shade, platform and associated civil works, painting etc. as approved by the department.
F. FIRE ALARM
Supply, intallation, testing and commissioning of Conventional optical smoke detector with base complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of Conventional Hooter complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of PVC Body Manual Call Point (non-glass type) complete in all respect Morley, Apollo, System Sensor, Agni
Supply, intallation, testing and commissioning of Conventional Fire Alarm Panel System Sensor, Ravel, Agni
Microprocessor controller and LCD Display
Supplying, drawing, connecting, testing & commissioning of 2 corex1.5 sq.mm multi stranded copper conductor, pvc insulated PVC sheathed, aluminium myler tape shielded armoured cable suitable for Fire Alarm System. Havells, Polycab, Crystal, Gloster.
SITC of Automatic gearless elevator/lift of 8(eight) passengers capable of load about 544 kgs @ 1mt/sec. with car size 1100mmx1300mm deep, car enclosure, entrance, machine room, power operated automatic door operation including necessary assembling at site make Omega Elevators.
(C) BOYS HOSTEL
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
(b) Lift above 1.5 m upto 3.0 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with naturally occuring sand gravel under floors including watering ramming, consolidating and dressing complete with a lead of 50m (i) within 15 Km
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 t coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4Kanhaighat coarse sand)
(i) above plinth level upto 1st floor level.
MS & SS STEEL WORK
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint .
(i) In beams & joists with connecting plates or angles cleats as in main & cross beams, hip & jack rafters, purlins connected to common rafter and the like.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
FLOORING
Providing and Laying vitrified floor tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, laid on 20 thick cement mortar 1:4 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged) (i)Branded
Providing and Laying vitrified tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, in Skirting , raiser of steps over 12 thick bed of cement mortar 1:3 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged)(i)Branded
ALUMINIUM WORK
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade ( 35 mm thick WPC Panelling).
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade ( 12 mm thick WPC Panelling).
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade (6mm thick Aluminium grill). Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade (6mm thick Aluminium grill).
Providing and Fixing galzing in aluminium door windows ventilator shutters and partition etc with EPDM rubber/neprene gasket etc .complete as per the architectural drawing and the directions of enigineer in charge (a)With flot glass panes of 4mm thickness
Providing and fixing AL sliding bolts Bright finished or black enamelled with nut & screws etc.complete (a) 300 x 16 mm.
Providing & fixing Al. Tower bolts (barrel type) with screws etc. complete.(a) 250 x 10 mm
Providing & fixing Al. handles with necessary screws etc. complete. (a) 125 mm
ROOFING & CEILING
Trapzoidal Pre painted profile sheet roofing of appoved brand DYNA Roof or Equivalent with selt driling screws of 68mm long Xloy coated screw with PVC washer & caps Compete,Excluding the coat of purlins & trussesPre painted Galvalume Sheet (PPGL) i) Profile sheet 0.50mm/4.2kgs/Sqm
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter &
Providimg and fixing false ceiling at all height including providing and fixing of frame work made of special sections,power pressed from M.S. Sheets and galavanized with zinc coating of 120gms/sqm ( both side inclusive) as per is 277 and consisting of angle cleats of size 25mm wode X 1.6 mm thick with flanges of 27mm flanges of 20mm amd 30mm long , the perimeter of ceiling fixed to wall /Partition with the help of rawl plugs at 450mm centerr,with 25mm long dry wall screws @ 230mm interbal, including fixing of gypus board to(a)Fully Perforated Gypsum board of size 1200 X2400 X12.4mm Having approx.15% perforated area with perforation size and pattern as approved by engineer Incharge
SH:- MISCELLANEOUS WORK
Supply & fixing of 50 mm thick panels of size 2400/2700/3000 mm length and 600 mm wide having Tongue & Groove joint system for walls, partitions and floor. The panels are made of two fibre reinforced cement sheets enclosing a light weight aerated concrete core composed of cement & binders. The fibre reinforced cement sheets are confirming to IS 13000-1990 or IS-14862-2000 Classification Type A(with upto amendment took place). These panels need to meet transverse load & modulus of rupture requirements as per ASTM-E-72:98 & IS 2380 Part4. The panels are laid on G.I floor channel of 1 mm thick and 14x50/75x25 mm and ceiling channel of size 38x50/75x38 mm. The rate should include hard ware, Labor, transport, lifting charges and wastages etc. as a complete item of work excluding finising, fitting etc and partions laid as per specification, drawing & as directed by engineer incharge.
SH : FINISHING
12mm cement plaster 1:4(1 cement:4 kanhaighat coarse sand)
15 mm cement plaster 1:4(1 cement:4 kanhaighat coarse sand)
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand)finished with a floating coat of neat cement.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work (three or more coats) to give even shade
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering (two or more coats) with oil bound washable distemper of approved quality on new work including priming coat to give an even shade.
SH : MISCELLANEOUS
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
Providing & fixing M.S. holder bat clamps embedded in & i/c cement concrete blocks 112.5 mm X 112.5 mm of 1:2:4 mix (1 cement:2 coarse sand:4 hard stone ballast 20 mm & down gauge).a)150 mm diameter
Providing & fixing on walls face G.I. head for rain water pipe i/c filling the joints spun yarn soaked in neat cement slurry & cement mortar 1:2(1 cement:2 fine sand). a) 150 mm diameter.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 kanhaighat coarse sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 kanhaighat coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Water Supply and Sanitary Installation
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:3:6(1 cem :3 Kanhaighat coarse sand:: 6 graded stone aggrt. 40mm nominal size).
(c) 1: 2 : 4 (1 cem : 2 Coarse sand : 4 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing an
Reinforcement for R.C.C.work including bending,binding and placing in position complete
(b) TMT bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain
( c )Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(f)Edges of slab and breaks in floor not exceeding 1m in depth
2nd class (local first class) brick work in foundation and plinth level in cement mortar 1:4(1 Cem:4C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand:) in superstructure (a)above plinth.
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required (a):White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush complete including painting of fitting and brackkets cutting and making good the wall and floors wherever required. one urinal basin with 5 litre white PVC automatic flushing cistern
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type SONA).
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
(b) 75 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 25mm diameter
Providing and fixing grating of approved quality for Nahni trap Stainless steel, 125mm nominal diameter with 25mm waste hole
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 1000 litres net capacity storage tanks
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Fitting Accessories
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS15W LED 8575 complete with connection as rqd. (Havell's)
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
MS & DB Boards
P/F (following capacity TP & N) dis-connection fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuse including drilling holes in the cubicle panel board, making connection as reqd. 1. 100 amp TP & N.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Fire Extinguisher & Fire Detector System
SECTION-A
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
100mm dia
80mm dia
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing standard short size stainless steel branch pipe with gunmetal nozzle 16mm dia outlet with standard instantaneous type 63mm dia coupling (ISI marked)
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.
Supplying, installation,testing and commissioning of stainless steel office plates and having 6mm nominal thickness, upto 200mm outer dia. And internal dia. Suitable to reduce pressure to between 3.2 to 3.5 kg/sq.mm complete as required.
Providing and fixing gunmetal single acting air release valve with screwed inlet 25mm dia as per IS 12992 reted for 20kg/sq.cm.
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanfes as per table "E" complete in all respects.
100mm dia with lever
Providing and fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
100mm dia
SECTION-B
HAND APPLIANCES
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
Providing and fixing at approved location approved make 4 nos., for buckets of 24 guage galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black nd gold including stand fabricated out to sheet metal (16 guage) shade, platform and associated civil works, painting etc. as approved by the department.
External Electrical Works
P/L 50mm2 4-core pvc ins.(heavy duty)Cu. cond. armoured cable of 1.IKV grade of size not exceedng 25mm2 but not exceeding 120 sqmm direct in ground i/c excavation,sand cushioning protective covering and refilling the trench etc.as reqd.
(D) GIRLS HOSTEL
DISMANTLING
Dismantling sheet roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of unserviceable materials within 50 m lead.(a) G.I. sheet roofing
Dismantling ballies in posts, purlins or rafters including stacking the materrials within 50 m. lead.
Dismantling doors, windows and clerestory windows ventilators etc.(wood or steel) shutters including choukhats, architraves, holdfasts and other attachment etc. complete and stacking them within 50 m lead.(a) Not exceeding 3 sqm in area.
Demolition of brick work above G.L. upto floor two level including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead.
Demolition of brick work below G.L. upto 1 m depth including stacking of serviceable materials within 50 m lead and disposal of unserviceable materials within 50 m lead(a) In cement mortar
Demolition above G.L.upto floor two level including disposal of unserviceable materials with 50 m lead(i)Unreinforced cement concrete upto 15 cm. thickness.
Dismantling textile covering in ceiling/walling including frames and cover fillets stacking of serviceable materials and disposal of unserviceable materials within 50 m lead.
Demolition above G.L. upto floor two level including disposal of unserviceable materials with 50 m lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. work.(a) R.C.C. work.
Demolition below G.L. upto 1 m.depth including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead and including cutting the necessary reinforcement and separating out from R.C.C./R.B. work.(a)R.C.C. Work
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
(b) Lift above 1.5 m upto 3.0 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with naturally occuring sand gravel under floors including watering ramming, consolidating and dressing complete with a lead of 50m (i) within 15 Km
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 t coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4Kanhaighat coarse sand)
(i) above plinth level upto 1st floor level.
MS & SS STEEL WORK
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint .
(i) In beams & joists with connecting plates or angles cleats as in main & cross beams, hip & jack rafters, purlins connected to common rafter and the like.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
FLOORING
Providing and Laying vitrified floor tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, laid on 20 thick cement mortar 1:4 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged) (i)Branded
Providing and Laying vitrified tiles in different sizes( thickness to be specified by the manufacturer) with water absorptions less than 8% and confirming to IS:15622 of approved make in all colours and shades, in Skirting , raiser of steps over 12 thick bed of cement mortar 1:3 including grouting the joints with white cement and matching pigments etc. Complete.(a)Size of tiles 600X600 ( Double Charged)(i)Branded
ALUMINIUM WORK
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade ( 35 mm thick WPC Panelling).
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade ( 12 mm thick WPC Panelling).
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade (6mm thick Aluminium grill). Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade (6mm thick Aluminium grill).
Providing and Fixing galzing in aluminium door windows ventilator shutters and partition etc with EPDM rubber/neprene gasket etc .complete as per the architectural drawing and the directions of enigineer in charge (a)With flot glass panes of 4mm thickness
Providing and fixing AL sliding bolts Bright finished or black enamelled with nut & screws etc.complete (a) 300 x 16 mm.
Providing & fixing Al. Tower bolts (barrel type) with screws etc. complete.(a) 250 x 10 mm
Providing & fixing Al. handles with necessary screws etc. complete. (a) 125 mm
ROOFING & CEILING
Trapzoidal Pre painted profile sheet roofing of appoved brand DYNA Roof or Equivalent with selt driling screws of 68mm long Xloy coated screw with PVC washer & caps Compete,Excluding the coat of purlins & trussesPre painted Galvalume Sheet (PPGL) i) Profile sheet 0.50mm/4.2kgs/Sqm
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter &
Providimg and fixing false ceiling at all height including providing and fixing of frame work made of special sections,power pressed from M.S. Sheets and galavanized with zinc coating of 120gms/sqm ( both side inclusive) as per is 277 and consisting of angle cleats of size 25mm wode X 1.6 mm thick with flanges of 27mm flanges of 20mm amd 30mm long , the perimeter of ceiling fixed to wall /Partition with the help of rawl plugs at 450mm centerr,with 25mm long dry wall screws @ 230mm interbal, including fixing of gypus board to(a)Fully Perforated Gypsum board of size 1200 X2400 X12.4mm Having approx.15% perforated area with perforation size and pattern as approved by engineer Incharge
SH : FINISHING
12mm cement plaster 1:4(1 cement:4 kanhaighat coarse sand)
16 mm cement plaster 1:4(1 cement:4 kanhaighat coarse sand)
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand)finished with a floating coat of neat cement.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work (three or more coats) to give even shade
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering (two or more coats) with oil bound washable distemper of approved quality on new work including priming coat to give an even shade.
SH : MISCELLANEOUS
Supply & fixing of 50 mm thick panels of size 2400/2700/3000 mm length and 600 mm wide having Tongue & Groove joint system for walls, partitions and floor. The panels are made of two fibre reinforced cement sheets enclosing a light weight aerated concrete core composed of cement & binders. The fibre reinforced cement sheets are confirming to IS 13000-1990 or IS-14862-2000 Classification Type A(with upto amendment took place). These panels need to meet transverse load & modulus of rupture requirements as per ASTM-E-72:98 & IS 2380 Part4. The panels are laid on G.I floor channel of 1 mm thick and 14x50/75x25 mm and ceiling channel of size 38x50/75x38 mm. The rate should include hard ware, Labor, transport, lifting charges and wastages etc. as a complete item of work excluding finising, fitting etc and partions laid as per specification, drawing & as directed by engineer incharge.
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
Providing & fixing M.S. holder bat clamps embedded in & i/c cement concrete blocks 112.5 mm X 112.5 mm of 1:2:4 mix (1 cement:2 coarse sand:4 hard stone ballast 20 mm & down gauge).a)150 mm diameter
Providing & fixing on walls face G.I. head for rain water pipe i/c filling the joints spun yarn soaked in neat cement slurry & cement mortar 1:2(1 cement:2 fine sand). a) 150 mm diameter.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 kanhaighat coarse sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 kanhaighat coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Water Supply and Sanitary Installation
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 kanhaighat coarse sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 kanhaighat coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:3:6(1 cem :3 Kanhaighat coarse sand:: 6 graded stone aggrt. 40mm nominal size).
(c) 1: 2 : 4 (1 cem : 2 Coarse sand : 4 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing an
Reinforcement for R.C.C.work including bending,binding and placing in position complete
(b) TMT bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain
( c )Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(f)Edges of slab and breaks in floor not exceeding 1m in depth
2nd class (local first class) brick work in foundation and plinth level in cement mortar 1:4(1 Cem:4C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand:) in superstructure (a)above plinth.
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required (a):White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush complete including painting of fitting and brackkets cutting and making good the wall and floors wherever required. one urinal basin with 5 litre white PVC automatic flushing cistern
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type SONA).
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
(b) 75 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 25mm diameter
Providing and fixing grating of approved quality for Nahni trap Stainless steel, 125mm nominal diameter with 25mm waste hole
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 1000 litres net capacity storage tanks
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Fitting Accessories
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS15W LED 8575 complete with connection as rqd. (Havell's)
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
MS & DB Boards
P/F (following capacity TP & N) dis-connection fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuse including drilling holes in the cubicle panel board, making connection as reqd. 1. 100 amp TP & N.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Fire Extinguisher & Fire Detector System
SECTION-A
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
100mm dia
80mm dia
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing standard short size stainless steel branch pipe with gunmetal nozzle 16mm dia outlet with standard instantaneous type 63mm dia coupling (ISI marked)
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.
Supplying, installation,testing and commissioning of stainless steel office plates and having 6mm nominal thickness, upto 200mm outer dia. And internal dia. Suitable to reduce pressure to between 3.2 to 3.5 kg/sq.mm complete as required.
Providing and fixing gunmetal single acting air release valve with screwed inlet 25mm dia as per IS 12992 reted for 20kg/sq.cm.
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanfes as per table "E" complete in all respects.
100mm dia with lever
Providing and fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
100mm dia
SECTION-B
HAND APPLIANCES
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
Providing and fixing at approved location approved make 4 nos., for buckets of 24 guage galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black nd gold including stand fabricated out to sheet metal (16 guage) shade, platform and associated civil works, painting etc. as approved by the department.
External Electrical
P/L 50mm2 4-core pvc ins.(heavy duty)Cu. cond. armoured cable of 1.IKV grade of size not exceedng 25mm2 but not exceeding 120 sqmm direct in ground i/c excavation,sand cushioning protective covering and refilling the trench etc.as reqd.
(D) Developement Works
Compound wall / Fencing and Gates
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:3:6(1 cem :3 Kanhaighat coarse sand:: 6 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending,binding and placing in position complete
(b) TMT bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply) (a) Foundation footings, bases of columns etc. and mass concrete.
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
16 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint .
Storm Water Drain
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 40mm nominal size).
(a) 1:2:4(1 cem :2 Coarse sand:4 graded stone aggrt. 20mm nominal size).
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
SH : FINISHING
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Interlocking Paver Block Works
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
Providing laying & compacting granular base/sub-base according to lines, grades& cross-sections by using naturally occurring sand gravel/conforming to IRC Grade 2 of M.O.S.T. specification free from organic or other deleterious constituents compact by rolling with power roller of 8 to10 tonnes capacity in layers not exceeding 150 mm (spread thickness)including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge. ( with 41 Km lead)
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) P. C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 40mm nominal size).
Providing and laying 60 mm thick factory made cement concrete interlocking paver block (Rubber Moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern
(SH:-Ground sump with Elevated Platform-4Nos )
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 t coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 Kanhaighat graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 Kanhaighat graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(c) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttresses, plinth and the string courses and the like
(c )Columns, pillars, posts and struts (Circular or curved in plan).
(d) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(e) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(f) Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
MS & SS STEEL WORK
Steel glazed windows and ventilators of standard rolled steel section joints mitred and welded with 15 x 3 mm lugs 10 cm long with steel plugs embedded in cement concrete block 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20 mm nominal size) or wooden plugs and screws of rawl plugs and screws or with fixing clips with bolts and nuts as required including providing and fixing of 4 mm thick glass panes with glazing clips complete including applying a priming coat of approved steel primer excluding cost of metal beadings and other fittings except necessary hinges or pivots as required.(i) Ready made steel windows (side hung /top hung)
SH : FINISHING
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand)finished with a floating coat of neat cement.
Finishing walls weather shield paint of approved quality on new work (three or more coats) to give even shade
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 1000 litres net capacity storage tanks
P/F of self priming water pump 1 HP including necessary fitting of suction and delivery pipe and electrical complete as directed by the Engineer in charge.
M/S KIM and Sons Constructions and Equipments
Guigui Kamei
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid