Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical Non Responsive |
| 2 | Rejected-Technical 1038 S S T NAGAR PATIALA | Rejected-Technical Non Responsive |
Tender Value
₹37.3 L
EMD Value
₹74,683
Closing Date
19 Feb 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, DWSS, DIV.NO.1, PATIALA
EXECUTIVE ENGINEER, WATER SUPPLY AND SANITATION DIV.NO.1, PATIALA
Repair and Upgradation of P.H. Services in Washrooms of Block-A and Block-B of Govt. Dental College, Patiala (Under Head 4210, Capital Outlay on Medical and Public Health).
2026_WSS_160017_1
E-TENDER-32/WSSD/DIV.NO.1 PATIALA/EE/2025-26
National Competitive Bid
Civil Works - Buildings
Percentage
120 days
Govt. Dental College
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹74,683
6 Apr 2026
12 Feb 2026
20 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects.
15mm internal diametre pipe line.
20mm internal diametre pipe line.
25mm internal diametre pipe line.
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
SDR 11 CPVC pipes & fittings 20mm o/d
INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
SDR 11 CPVC pipes & fittings 25mm o/d
P/F CPVC Union
P/F CPVC Ball Valve
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition
Size 75 mm x 75 mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks.
Plastic Ball Cock with rod and Plastic Ball
Providing and fixing in position CPVC Tank Nipple
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in-Charge)
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect.
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Single Socket Type B
110mm o/d SWR UPVC pipe
90mm o/d SWR UPVC pipe
Dismantling H.C.I Soil pipes including disposal as desired by the Engineer-in-Charge.
100mm i/d H.C.I. pipe
75mm i/d H.C.I. pipe
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)
Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge.
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm o/d pipes
For 90mm o/d pipes
Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drawings, including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 metre, for all works other than connections to complete in all respects.
For depth not exceeding 2 m. below Ground level
For all classes of soil except rocky
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 (150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc.
Dismantling of terrazo flooring at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.
Size 600x600 mm
Labour for removing cinder on roofs complete in all respects
Supplying and filling cinder on roof (Ist story) including light ramming.
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)
For shutter area above 0.50 sqm
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In Charge. (Glazing and paneling to be paid for separately) :
For fixed portion and chawkhats
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge
4mm thick ACP Sheet
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item)
Float glass panes of 4mm thickness
Carriage of Malba with trolley
Scrapping of Cement Plaster complete in all respect
Plastering on underside of ceiling 10mm thick cement plaster 1:3
Cement rendering on plaster 1mm thick
115mm thick brick wall in cement sand mortar
Providing and fixing in position vitreous Chinaware white Indian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm, C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete
P/F of CPVC MTA 20 mm o/d
Vitreous white Chinaware Partition
Large partition size 75 x 16.5 x 36.5 cm
Deduction 3.50% for old material i.e. HCI pipe, GI pipe and CP fixture.
stage.html
html • 0.03 MB
techsummary_324819.pdf
cancelled_1.pdf
pdf • 0.95 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.08 MB
DNITForUploadingOfPHServicesWorkInBlockAAndBDentalCollege.pdf
Tender Documents • 10.90 MB
DrawingsOfPHServicesWorkInBlockAAndBDentalCollege.pdf
Tender Documents • 5.62 MB
BOQ_324819.xls
BOQ • 0.45 MB
CorrigendumUpto26022026.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .