| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.1 L+₹4.9 L (17.3%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.4 L+₹9.1 L (32.2%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹37.4 L+₹9.1 L (32.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
MINOR REPAIR WORK OF E/M NATURE IN MD ACCN AT NEW CANTT UNDER GE WEST PRAYAGRAJ.
2024_MES_662996_1
8733/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹96,000
Yes
29 Oct 2024
29 Jun 2024
10 Sept 2024
29 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
Receiving complaints from Concern In charge of Internal section (Power House) lodged by the occupants of electrification nature, rectification of the fault as per the complaint lodged by the user onward KWH meter in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light/Ceiling Fan, testing of Electronic meters or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engr-in-charge/users. Note - (i) All spares required i.e. tube light any type, Choke any type, CFL,LED, starter, bipin holder, starter holder etc accessories, required for repairing will be paid under relevant supply only items of this schedule.
INSTRUCTIONS -(a) Attending complaint including taking down/refixing of LED light fittings and repair/ Replacement part (Labour cost ) and minor repair shall be measured against Srl item No 1 of Sch 'A' (b) Cost of material for replacement of new items shall be measured and paid separately under relevant items of sch 'A' against supply only here-in-after (Item No 2 to 34) (c) Penalty : Penalty for not attending complaints within stipulated time frame will be the liable to Rs 500.00 of per day for non attending the complaints multiple number of days of delay (d) Priority -1 (to be done within 8 hours from time of lodging complaint): No light, repair/replacement of switches, fan regulator, replacing burnt/damaged wiring, replacement of burnt MCBS and Main switch, voltage fluctuation, current leakage and replacement of tube lights. (e) Priority -2 (to be done within 72 hours from time of lodging complaint): Replacement of fittings and fixtures replacement of choke starter replacement of meter, replacement of DBs and Main DB, repair of earthling lead. (f) Priority -3 (to be done within 07 days from time of lodging complaint): Replacement of fittings and fixtures, Ceiling Fan, Call bell switch board, point wiring etc (g) Contractor shall employ suitable tradesman having sufficient experience of Electrician work with suitable helpers to rectify the internal electrification defects, breakdown current leakage, replacement of Electrical items, wiring work, electronic meter testing Etc. (h) The quantum of work under a complaint shall be comprised as the each Qtr/ complaint nature issued with unique docket No. (j) Documentation and monthly progress report of complaints shall be maintained by contractor by providing supervisor and maintenance team preferably two dedicated team for Officers and PBOR OTM ACCN. (k) All documents i.e. complaint register, complaint slip, gate pass and register for use signature must be provide by contractor from date commencement of the CA.
Supply only in replacement of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Supply only in replacement of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
Supply only in replacement of socket outlet multipurpose 2/3 pin 5 amps flush button complete all as specified and directed.
Supply only in replacement of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply only in replacement of 15 Amps switch socket combination, 240V complete all as specified and directed.
Supply only in replacement of ceiling fan regulator step type 240 Volt AC complete all as specified and directed.
Supply only in replacement bell push flush type 5 amps complete all as specified and directed.
Supply only in replacement ceiling rose surface type complete all as specified and directed.
Supply only in replacement angle/batten type lamp holder, PVC/Polycarbonate type with back plate complete all as specified and directed.
Supply only in replacement of call bell, ding dong type, AC, 230 V, single pole complete all as specified & directed.
Supply only in replacement single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp 'B' Curve. complete all as specified and directed.
Supply only in replacement of modular switch 1 way, 10 amps, 230V AC, one way complete all as specified & directed.
Supply only in replacement of modular socket out let 2-in-1, 3 pin, 10 amp flush type 2 module complete all as specified & directed.
Supply only in replacement of modular switch flush type 20 amps, 230V AC single pole one way complete all as specified & directed.
Supply only in replacement of modular socket out let 2-in-1, 3 pin, 5 & 16 amp flush type 2 module complete all as specified & directed.
Supply only in replacement of modular fan regulator, 5 stepped, electronic type, single phase, 120 watt, 1/2 module including connection complete all as specified & directed.
Supply only in replacement of Modular metal flush box of 12 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 8 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 6 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 4 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 2 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 12 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 8 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 6 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 4 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 1/2 module complete all as specified and directed.
Supply only in replacement of Modular bell push flush type 6 amp, 1 module SP , 230V AC complete all as specified & directed.
Supply only in replacement MCB single pole, 6 to 32 amps rating, 240 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply only in replacement MCB single pole & Neutral, 40/63 amps rating, 240 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply only in replacement MCB Triple pole & neutral 63/100 amp, 440 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply only in replacement of PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI marked for proper insulation of joints in wire where complete all as specified and directed.
Supply only in replacement of condenser of 2.5 MFD, 240 Volt AC , conforming to IS - 1709 suitable for fans complete all as specified and directed.
Supply only in replacement of condenser of 1.5 MFD, 240 Volt AC , conforming to IS - 1709 suitable for fans complete all as specified and directed.
Supply & fixing in replacement of worn out/rusted sunken box of following sizes with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mm of following size along with new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
200 mm X 200 mm
100 mm X 100 mm
175 mm X 100 mm.
250 mm X 200 mm.
S&F in replacement of environmental friendly aesthetically designed ,decorative recess mounted 2W LED spot light for low ceiling height applications complete all as specified and directed. Make ;- Havells cat Part No.LHLDAUSADL8U002 or equivalent make as specified in P.S.
S&F in replacement of recess mounted 6W LED down lighter with pressure die-cast aluminium heat sink & clear PC as a cover in white powder coated finish with Independent electronic LED driver for low ceiling height applications complete all as specified and directed.
S&F in replacement of 15 W LED down lighter Ultra slim decorative aluminium casted recess mounted round fixture in white finish with opal diffuser and separate electronic driver ,suitable for low depth ceiling height applications complete all as specified and directed.
S&F in replacement of Slim, compact, aluminium die cast edge lit panel. surface mounted square fixture and separate electronic driver with high brightness LEDs with diffuser to give glare free light of 26 W complete all as specified and directed.
S&F in replacement of Recess mounted round down lighter Al pressure die –cast heat sink with high brightness LEDs with diffuser to give glare free light of 15 W LED 6500 K complete all as specified and directed.
S&F in replacement of wall bracket Decorative, wall mounting, Shiny stainless steel base & glass opal paint finish including 20 wall LED bulb fixture With bulb base B22 complete all as specified and directed.
S&F in replacement of dual wall bracket Decorative, wall mounting, metal and chrome & glass opal paint finish including 2X10 wall LED bulb fixture With bulb base E32 complete all as specified and directed.
S&F in replacement of Flexible led strips with uniform light distribution having dimensions 5000X10X.3 MM and 28 watt capacity and 72 LED per meter in and including driver complete all as specified and directed.
Supply and fixing in replacement of 36 W LED 2'x2' Panel Ultra slim recess mounted LED module with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for Armstrong / grid ceiling applications complete all as specified and directed. Make Philips Full glow Cat No. RC380B LED36S-6500G6 L60W60PSU ODS1 or equivalent make as specified in P.S.
S&F in replacement of 40 /42 W LED 2'x2' Panel surface mounting with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for surface /recess mounting applications complete all as specified and directed. Make -Philips full glow surface mount Cat No. SM367LED 42S-6500 G6L54W54 PSU OD or equivalent make as specified in P.S.
S&F energy saver LED batten fitting 20 watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting complete all as specified and directed.
S&F energy saver LED batten fitting 10 watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting complete all as specified and directed.
S&F in replacement LED tube rod 4 feet long of 20/21 watt ultra bright tube light with very high efficiency single side connection suitable for installation in existing T5/T8 with G13 Lamp holder 6500K/3000K complete all as specified and directed. Havells cat Part No. 20 W LED 3000 K LHFXCENNTN1W020 or equivalent make as specified in P.S. .
S&F in replacement of Ultra bright LED PLL with very high efficacy suited for installation in existing 2G11 lamp holders to give glare free light complete all as specified and directed.
S&F in replacement of LED LUMENO Lamp 0.5 W B22 Green complete all as specified and directed. Havells cat Part No. LHLDAEUEMONX05 or equivalent make as specified in P.S.
Supply ,fixing, testing and connecting LED Security light fittings 42 Watts , IP-65 cast aluminium housing in grey hammer tone stove enamelled finish outside with electric connection of Electronic driver and LED panel to be suitable size of copper cable with base plate and complete all as specified and as directed. Make - Philips Cat Part No. BRP331 LED 42 CW R5NPC PSU S1V1 or equivalent or equivalent make as specified in P.S.
S&F sheet metal enclosure TPNL MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCBs & MCCB 125 Amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar IP 43 - IK 09 suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
S&F in replacement double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar IP 43 - IK 09 complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar IP 43 - IK 09 complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F in replacement testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCB SPN 16-32 Amps 'C curve' complete all as specified and directed.
S&F MCB TP 40-63 A 415V 'C curve' complete all as specified and directed.
S&F MCB TPN 40-63 Amps, 'C curve' complete all as specified and directed.
S&F MCCB 125 Amps, 4 Pole, 415V, 25KA complete all as specified and directed.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including conduit medium grade ISI marked not less than 19 mm dia/ Casing caping of 19-20 mm with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized standard sunken boxes as per standard as per manufacturer norms / Polycarbonate appropriate size for surface mounting with earth dolly and standard grid, crown and cover plate for fixing of switches / sockets, fan regulators, with captive screws including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing for one light, fan, call bell, 5Amp independent socket point controlled by one switch including cutting the chases and making good the surface by cement mortar 1:3 and for matching / finishing of new surfaces either by means of plaster of peris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed. Note -Sunken boxes, mounting grid, cover plate and switch sockets and regulator shall be paid and measured separately.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in existing conduit medium grade ISI marked any size /any type with earth dolly and standard grid, crown and cover plate for fixing of switches / sockets, fan regulators, with captive screws including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing for one light, fan, call bell, 5Amp independent socket point controlled by one switch including cutting the chases and making good the surface by cement mortar 1:3 and for matching / finishing of new surfaces either by means of plaster of peris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed. Note -Sunken boxes, mounting grid, cover plate and switch sockets and regulator shall be paid and measured separately.
M&L Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm drawn in MS/PVC conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed.
M&L Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed.
M&L for cutting chases in brick walls, pinning in at the depth of 30 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring, submain wiring etc and making good and plastering the surface with cement or plaster of peris and matching with same colour scheme, cutting exceeding 10cm but not exceeding 30cm girth complete all as specified and directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC 1:3:6 type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia med. grade, lugs, main earthing lead upto 7.5 mtr including charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe complete all as specified and directed.
M & L for repairing of broken earthing pits chamber with PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with 40 mm thick RCC cover of existing size 1:2:4 type B0 using 12.5 mm graded stone aggregate, reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe complete all as specified and directed.
Material and labour for new earthing pit with PCC 1:3:6 type C-1 using 20 mm graded stone aggregate chamber with 40 mm thick RCC cover 1:2:4 type B0, reinforced with 8 mm dia bar, 3 Nos. both way, funnel with wire mesh, water poring arrangement ,connecting main Earthing lead from Earthing pit to Test point /equipment all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed.
Supply and fixing in replacement of worn out wooden batten/ 20 mm dia PVC Conduit with Non Metallic Rigid PVC casing caping ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
Supply and fixing in replacement of worn out wooden batten/ 25 mm dia PVC Conduit with Non Metallic Rigid PVC casing caping ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
Schedule of Credit (MINUS) Rs. 136975.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
Aawadh associates (BID ID -3063453)
Ambrish Builders (BID ID -3061100)
DINESH ELECTRICALS (BID ID -3068499)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .