Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAdmitted-Finance 57 B FEEDER ROAD GROUND FLOOR 57 B FEEDER ROAD BARRACKPORE NORTH 24 PARGANAS WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹40.3 L | L1 | Admitted-Finance |
| 2 | L2₹41.0 L+₹65,671 (1.63%)Admitted-Finance | ₹41.0 L+₹65,671 (1.63%) | L2 | Admitted-Finance |
| 3 | L3₹42.5 L+₹2.2 L (5.46%)Admitted-Finance | ₹42.5 L+₹2.2 L (5.46%) | L3 | Admitted-Finance |
| 4 | L4₹46.6 L+₹6.3 L (15.5%)Admitted-Finance 116 SHANTINAGAR ROAD BHADRAKALI UTTARPARA HOOGHLY WEST BENGAL 712232 | HOOGHLY | WEST BENGAL | 712232 | ₹46.6 L+₹6.3 L (15.5%) | L4 | Admitted-Finance |
| 5 | L5₹47.2 L+₹6.9 L (17.1%)Admitted-Finance 217 TILJALA ROAD TILJALA ROAD KOLKATA TILJALA ROAD KOLKATA WEST BENGAL 700046 KOLKATA WEST BENGAL 700046 | KOLKATA | WEST BENGAL | 700046 | ₹47.2 L+₹6.9 L (17.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RIGHT ADDRESS L2 | Lyric International L6 | AIR Q SOLUTIONS L4 | AIR COOLING SOLUTIONS L5 | ALPHA GAMMA AIR SOLUTIONS PVT. LTD. L1 | TRANSTECH L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of Air Cooled type outdoor units of VRF system having hermetically sealed inverter scroll compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, top discharge throw condenser fan, Condenser fan - motor unit, all system controls-safety. The system should have flexibility to handle total 280 Rmt of ref. piping. ODU shall be placed on structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration. The system shall have minimum COP of 3.7 at ARI condition as per CPWD guidelines. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP protection will be suitable for outdoor installation. The VRF System shall have green ref. gas only- R410A/ R407.The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 asbelow and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity >40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) | 63 | HP | 17,500 ₹11,02,500 Lowest | 22,500 ₹14,17,500 | 32,800 ₹20,66,400 | 19,470 ₹12,26,610 | 33,000 ₹20,79,000 | 29,994 ₹18,89,622 |
| 2.00Indoor Units Supply, Installation, Testing & Commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, fresh air intake connector for cassettes etc. of various capacities as per specifications. Power cabling (3mtr from unit) with conduit from power socket & plug top to indoor is inclusive of price. | |||||||||
| 2.01 | Hi-Wall Type Indoor Unit - Capacity - 0.8TR | 2 | Nos. | 17,900 ₹35,800 Lowest | 26,000 ₹52,000 | 36,500 ₹73,000 | 22,407 ₹44,814 | 18,000 ₹36,000 | 20,584 ₹41,168 |
| 2.02 | Hi-Wall Type Indoor Unit - Capacity - 1.0TR | 2 | Nos. | 19,500 ₹39,000 | 27,000 ₹54,000 | 38,700 ₹77,400 | 22,941 ₹45,882 | 19,000 ₹38,000 Lowest | 22,117 ₹44,234 |
| 2.03 | Hi-Wall Type Indoor Unit - Capacity - 1.3TR | 2 | Nos. | 22,250 ₹44,500 | 27,500 ₹55,000 | 39,300 ₹78,600 | 23,408 ₹46,816 | 20,000 ₹40,000 Lowest | 25,486 ₹50,972 |
| 2.04 | Hi-Wall Type Indoor Unit - Capacity - 1.5TR | 13 | Nos. | 22,700 ₹2,95,100 | 30,500 ₹3,96,500 | 42,200 ₹5,48,600 | 26,679 ₹3,46,827 | 21,000 ₹2,73,000 Lowest | 26,099 ₹3,39,287 |
| 2.05 | Hi-Wall Type Indoor Unit - Capacity - 1.7TR | 9 | Nos. | 25,100 ₹2,25,900 | 31,900 ₹2,87,100 | 42,600 ₹3,83,400 | 27,413 ₹2,46,717 | 22,000 ₹1,98,000 Lowest | 28,794 ₹2,59,146 |
| 2.06 | Hi-Wall Type Indoor Unit - Capacity - 2.0TR | 3 | Nos. | 25,250 ₹75,750 | 31,900 ₹95,700 | 45,500 ₹1,36,500 | 27,413 ₹82,239 | 22,500 ₹67,500 Lowest | 28,794 ₹86,382 |
| 2.07 | Hi-Wall Type Indoor Unit - Capacity - 2.5TR | 6 | Nos. | 28,500 ₹1,71,000 | 63,900 ₹3,83,400 | 64,200 ₹3,85,200 | 50,871 ₹3,05,226 | 25,000 ₹1,50,000 Lowest | 32,592 ₹1,95,552 |
| 3.00VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS WITH PRECAST INSULATION | |||||||||
Tender Value
₹41.9 L
EMD Value
₹83,870
Closing Date
28 May 2026, 12:00 pmClosed
Executive Engineer (RAC)
RAC unit located in the Old building , IIT KGP - 721302
Supply, Installation, Testing and Commissioning of Air conditioning work for Rubber Technology Research Lab,RTC of IIT Kharagpur
2026_IITKG_907538_1
IITKGP/RAC/VRF/RTC/2026 (2nd Call)
Open Tender
Electrical Works
Item Rate
100 days
Rubber Technology Resarch Lab
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹83,870
RAC unit located in the Old building , IIT KGP
17 Jun 2026
5 May 2026
29 May 2026
5 May 2026
28 May 2026
5 May 2026
13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of Air Cooled type outdoor units of VRF system having hermetically sealed inverter scroll compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, top discharge throw condenser fan, Condenser fan - motor unit, all system controls-safety. The system should have flexibility to handle total 280 Rmt of ref. piping. ODU shall be placed on structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration. The system shall have minimum COP of 3.7 at ARI condition as per CPWD guidelines. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP protection will be suitable for outdoor installation. The VRF System shall have green ref. gas only- R410A/ R407.The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 asbelow and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity >40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) | 63 | HP | - | - |
| 2Indoor Units Supply, Installation, Testing & Commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, fresh air intake connector for cassettes etc. of various capacities as per specifications. Power cabling (3mtr from unit) with conduit from power socket & plug top to indoor is inclusive of price. | |||||
| 2.01 | Hi-Wall Type Indoor Unit - Capacity - 0.8TR | 2 | Nos. | - | - |
| 2.02 | Hi-Wall Type Indoor Unit - Capacity - 1.0TR | 2 | Nos. | - | - |
| 2.03 | Hi-Wall Type Indoor Unit - Capacity - 1.3TR | 2 | Nos. | - | - |
| 2.04 | Hi-Wall Type Indoor Unit - Capacity - 1.5TR | 13 | Nos. | - | - |
| 2.05 | Hi-Wall Type Indoor Unit - Capacity - 1.7TR | 9 | Nos. | - | - |
| 2.06 | Hi-Wall Type Indoor Unit - Capacity - 2.0TR | 3 | Nos. | - | - |
| 2.07 | Hi-Wall Type Indoor Unit - Capacity - 2.5TR | 6 | Nos. | - | - |
| 3VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS WITH PRECAST INSULATION | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.38 MB
BOQ_953878.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .