| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.7 L+₹1.3 L (13.5%)Rejected-Finance NO 21 BRAMIN STREET KORATTUR CHENNAI 600080 | CHENNAI | CHENNAI | TAMIL NADU | 600080 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
9 Jan 2021, 6:00 pmClosed
AGE(I) Navy Chennai
AGE(I) NAVY CHENNAI Fort Saint George Chennai 600009
REPAIRS TO ROOF TREATMENT AND REPAIRS TO BROKEN CHAJJAS AND FINS AND REPAIR/REPLACEMENT OF SOIL WASTE PIPES OF CERTAIN BUILDINGS OF ZONE A NAVY UNITS IN CHENNAI UNDER AGE(I) NAVY CHENNAI
2020_MES_391533_3
AGE(I)/NAVY/CHN/8147 of 2020 - 21
Open Tender
Civil Works
Item Rate
120 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹19,400
Yes
4 Feb 2021
22 Dec 2020
11 Jan 2021
22 Dec 2020
9 Jan 2021
26 Dec 2020
Amount
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC padding (1:2:4) type B-1 (20 mm graded aggregate) thickness as specified to bring uniform slope in floors/ roof slab complete all as specified and directed by Engineer-in-Charge.
M&L for APP polymeric water proofing minimum weighing 3.00 Kg per sqm and minimum 3 mm thick reinforced with polyster non woven fabric laid over roof surface with 100 mm over lap and including vertical surfaces upto required height and tucking into grooves and sealing complete with thermofusion, torch application over a tack coat of hot bitumen 85/25 @1.20 Kg/sqm over compatable primer at 0.40 ltr/Sqm including cleaning surfaces and finally one coat of hot blown bitumen 85/25 @ 1.20 Kg per sqm applied over water proofing membrane all as per instructed manufacturer instructions and applying two coats of aluminium paint over a coat of primer on APP membrane complete all as specified and directed.
M&L for repair of broken / rusted RCC work such as fascia of roof slab, ceiling, chajjas, columns, beams etc upto required thickness with 'Ready-mix reinforced acrylic fibre 'cementious' mortar material (micro concrete) after cleaning & removing loose particles, grease, oil or other materials, applying 'epoxy zinc primer' over cleaned reinforced steel and providing new steel re-inforcement and cage covered with fibre mesh all as per manufacturer's instructions including dismantling of old damaged / cracked RCC portions and finished the surfaces even and smooth including necessary scaffolding up to G+4 bldg all complete as directed. Make : M/s Dr Fixit (Pidilite), Fosroc, Berger Paints or equivalent
All as per Sl item No. 4 above but for 5th to 8th storey bldg
All as per Sl item No. 4 above but for 9th to 10th storey bldg
Taking down cement plaster of any description, on brick walls or stone walls,etc. including raking out joints, hacking for key, scrubbing down with water, etc upto (G+4) bldg complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaes in CM (1:4) and finised even and smooth (without using extra cement) using WPC @ 2% all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finised even and smooth (without using extra cement) all as specified and directed.
M&L for 10 mm thick rendering in CM (1:3) on ceiling/soffits etc all as specified and directed.
Supply only Integral water proofing compound.
M&L for preparation of new plastered surface on walls and applying two coats of oil bound distemper over a coat of primer all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
M&L for complete removal of old treated/treatment removed surfaces of wall and applying two coats of exterior weather proof emulsion (Colour as approved by AGE(I)) over a coat of primer as approved all as specified and as directed.
M&L for preparation new plastered surfaces plastered and applying three coat of white wash on Ceilings all as specified and as directed.
S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors for 110 mm dia incl all necessary fittings all as specified and as directed.
All as per Sl item No. 16 above but fixed on walls for G + 4 storey bldgs including erection of necessary scaffolding/supports
All as per Sl item No. 16 above but fixed on walls from 5th to 8th storey bldgs including erection of necessary scaffolding/supports
All as per Sl item No. 16 above but fixed on walls from 9th to 10th storey bldgs including erection of necessary scaffolding/supports
S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors for 75 mm dia incl all necessary fittings all as specified and as directed.
All as per Sl item No. 20 above but fixed on walls for G + 4 storey bldgs including erection of necessary scaffolding/supports
All as per Sl item No. 20 above but fixed on walls from 5th to 8th storey bldgs including erection of necessary scaffolding/supports
All as per Sl item No. 20 above but fixed on walls from 9th to 10th storey bldgs including erection of necessary scaffolding/supports
S&F in repairs PVC (SWR) bends any radius for 110 mm dia all as specified and as directed.
S&F in repairs PVC (SWR) bends any radius for 75 mm dia all as specified and as directed.
S&F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal for 110 mm dia all as specified and as directed.
S&F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal for 75 mm dia all as specified and as directed.
S&F PVC (SWR) branch piece, double (double Y), equal or unequal for 110 mm dia all as specified and as directed.
S&F PVC (SWR) branch piece, double (double Y), equal or unequal for 75 mm dia all as specified and as directed.
S&F in repairs PVC (SWR), junction single, (Single T) equal or unequal for 110 mm dia all as specified and as directed.
S&F in repairs PVC (SWR), junction single, (Single T) equal or unequal for 75 mm dia all as specified and as directed.
S&F in repairs PVC (SWR), junction double, (double T), equal or unequal for 110 mm dia all as specified and as directed.
S&F in repairs PVC (SWR), junction double, (double T), equal or unequal for 75 mm dia all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) including removing serviceable tiles to store and rubbish off the premises not exceeding 100 metre complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15mm thick of CM (1:6) for laying of floor finishes complete all as specified and as directed.
M&L for backing coat 10mm thick on fair faces of brick work or concrete wall surfaces in CM (1:4) complete all as specified and as directed.
M&L for non skid coloured ceramic tiles area exc 0.06 Sqm but not exc 0.11 Sqm having 7 mm thick in floors set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed coloured ceramic wall tiles 300x200/450 x 7 mm thick for work on vertical surfaces such as skirting, dado and set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
kvs constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .