Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC HN 34 WARD NO 2 AT AND PO HINAUTI TEHSIL SIHAWAL DISTT SIDHI M P | SIDHI | MADHYA PRADESH | 486670 | L1 | Accepted-AOC LOWEST VALID BIDDER | |
| 2 | L2₹22.6 L+₹2.8 L (13.9%)Rejected-Finance 225 KADAMTALA LANE PIPULPATI HOOGHLY 712 103 | HOOGHLY | WEST BENGAL | 712103 | L2 | Rejected-Finance L2 BIDDER | |
| 3 | L3₹22.9 L+₹3.0 L (15.3%)Rejected-Finance | L3 | Rejected-Finance L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
17 May 2025, 2:00 pmClosed
Superintendent, ESI Hospital Bandel, Hooghly
ESI Hospital Bandel, Hooghly 712123
Supply and installation of UPS System for Medical services and AMC and item rate for UPS installed at This Hospital
2025_LD_841249_1
ESIH/BDL/1494
Open Tender
SUPPLY OF ELECTRICAL GOODS/EQUIPMENTS
Item Rate
730 days
ESI Hospital Bandel, Hooghly 712123.
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1 L
Yes
23 May 2025
2 May 2025
19 May 2025
2 May 2025
17 May 2025
2 May 2025
Amount
Supply, Installation, testing & commissioning of 1x 10KVA UPS system configuration with 3Phase Input and 3 Phase Output True On Line Double Conversion UPS including Battery Circuit Breaker for Each Module CRCA housing with all required fixing accessories and hardware, Inbuilt Galvanic Isolation Transformer, Inbuilt Static switch bypass and inverter in each UPS module, In-Built Manual Maintenance by-pass, Battery Racks MS Powder Coated etc complete as required. Make - AAL
UPS 1 KVA single phase 220V/ 220V
UPS 500VA single Phase 220v/220V
UPS 2 KVA Single Phase 220V/220V
UPS 5 KVA 415V/220V
200VA UPS 20 min Bcakup For Computer
10 KVA 3ph in 3ph Out
Supplying, installation, testing and commissioning of UPS L.T. panel fully compartmentalized cubical type sheet clad floor mounted totally enclosed , extensible on both sides, switch board suitable for use on 415 Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium bus bars with current rating of 0.8 Amp/sq.mm, interconnection etc. with indication lamps, accessories etc, as required as per specification and schematic diagram as required. ( UPS Main Panel)
Supply,laying and testing of undernoted sizes of copper conductor XLPE insulated PVC sheathed and overall PVC sleeved 1.1KV grade power distribution cables confirming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall /racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc.,as required. 1c x 16 Sq.mm
Supply, laying and testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4*10 Sq.mm
Supply, laying and testing of undernoted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 X 4 Sq.mm Supply, laying and testing of undernoted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 X 4 Sq.mm Supply, laying and testing of undernoted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 X 4 Sq.mm
8 Way Vertical DB: 100 Amps TPN MCCB as Incomer(10 KA) 6 Nos. of 63Amps TP MCB as Outgoing
SITC of IGBT 100A
SITC of HRC FUSE 120A or any
SITC of 3 PHASE INDUCTOR 10 KVA or any Rating
SITC of 3 PHASE SENSING TRANSFORMER
SITC of 1 PHASE SENSING TRANSFORMER
SITC of PARLELL INTERFACE CARD
SITC of PARLELL CONTROLE CARD
SITC of SCR SNUBBER
SITC of COOLING FAN
SITC of RECTIFIER INTERFACE CARD
SITC of BATTERY 7AH 12V
SITC of BATTERY 28AH 12V
SITC of BATTERY 100 AH 12V
SITC of BATTERY 120 AH 12V
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required as per specification. 20mm dia PVC conduit
Wiring With 2x1.5 Sqmm Wire
Wiring With 2x3 Sqmm Wire
Supply and Laying of 3.5 CX 120 Sqmm Al Armoured Cable
Supply and Laying of 3.5 CX 240 Sqmm Al armoured Cable
Supply of 28 W Led Light Fixture
AMC Charge (UPS) Maintenance of the whole System Installed at this Hospital
HALDER ENTERPRISE (BID ID -6406548)
P.S.ENTERPRISE (BID ID -6399131)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .