Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹15.9 LAccepted-Finance | L 1 | Accepted-Finance Lowest Bidder 1 | |
| 2 | L2₹16.2 L+₹34,102.01 (2.15%)Accepted-Finance | L2 | Accepted-Finance Lowest Bidder 2 |
Tender Value
₹17.1 L
EMD Value
₹17,100
Closing Date
17 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of the Executive Engineer, PWD., Buildings Construction and Maintenance Division, B block, 6th floor, District Collectorate campus, Tirupathur-635 601
Upgradation of Infrastructure arrangements for MNCU ward at 4th floor of MCH building in Government Head Quarters Hospital at Tirupathur in Tirupathur District
2026_PWD_720927_1
01/TPT-DVN /2026-27/10/Dt.02.11.2026
Open Tender
Civil Works - Buildings
Lump-sum
Tirupattur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹17,100
17 Nov 2026
2 Nov 2026
17 Nov 2026
2 Nov 2026
17 Nov 2026
2 Nov 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying and Laying Polyester, Washable and stain free cloth(Bio-Active fabric washable germfree suitable for dialysis room) curtain system with maximum curtain cloth height 230cm ( top 30cm white colour net and 200cm light blue colour as per approval) stitching with stiffener tape, pleats, ironing and laying around Each bed using sliding wheels two nylon rollers, nylon axil and tangle free nylon’swivel stem with chrome-plates stell hook, curtain track should be supported in roof using 20x20mm,2mm thick sixed aluminium tubes same space with end caps in two sides using all necessary fittings. | |||||
| 1.01 | As per the direction of engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling with powder coated MS cup, all leads and lifts including all labour charges etc., complete.(unpleated length of the cloth measurement will be considered in cloth measurement)/ supplying and fixing powder coated 20mm dia . GI round tube hanging support of required length (app. length 1.10m)one end fixing from slab by using 6mm dia expansion bolt at a distance not more than 2m,c/c down end fixed powder coated aluminium channel frame 45x20mm x1mm thick section by using SS screw as per the Direction of Engineer in charge including conveyance. (Dr.No.80B/2025-26) | 133.45 | Sq.m | 1,500 | ₹2,00,175 |
| 2Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. | |||||
| 2.01 | 10mm OD 0.90mm thick copper pipe | 78 | Rm | 374.8 | ₹29,234.4 |
| 2.02 | 15mm OD 0.90mm thick copper pipe | 148 | Rm | 544.9 | ₹80,645.2 |
| 3 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber "O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. 15mm Isolation Valve | 3 | Nos | 1,446 | ₹4,338 |
| 4 | Bed Head Panel of size 1m length, height 0-0.30 cm and depth of 4". The aluminium powder coated with requirement colour for provision points of O2-2 Nos., Air 1 No., Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with 1V - bottle holder fixing to the wall hanging including monitor stand etc., complete. | 13 | Nos | 19,509 | ₹2,53,617 |
| 5Supply and Installation of 74 mm Drywall Partition with two layers of MGO-Magnesia Cement board, square edge, Magnesia cement core panels of size 1200x2400x12mm, volume density 1000kgs/m3, weight 12kg/m2 installed by using Auminimum channel.The Aluminimum channel 1.5mm thick, length 3600mm fixed to the floor and soffit ceiling with suitable fasteners at 300mm staggered centers. Silica noise and fire rated silicon sealant/Matt to be caulked along the lining frame before fixing the Aluminimum channels. Then Aluminimum channel of 25x50x1.5mm thick should be placed into the floor/head channel positioned vertically at 600mm centers. | |||||
| 5.01 | Extra reinforcement to be provided at openings (doors, windows, etc). Synthetic Polyfiber, 1000 gsm density, thickness 50mm, width 600mm is held in position with Stick S7 dab spots inbetween Aluminimum Channel. Magnesia Cement board 1200X2400X12mm is fastened onto the Aluminimum Channel behind in staggered manner using self drilling (drill tip) fasteners at 300mm centers. 4mm gap should be maintained between boards on all sides. Repeat the process similarly on the other side of the framework to get 74 mm thick partition system. 4mm gap between boards to be filled in full depth by using Jointing Compound as per given recommendations and guidelines.Technical Parameters Fire (Class) – 1 & P, Acoustics - STC 43, Thermal conductivity(W/mk)– 0.118, Climate (°C, RH) – 50, 95, Light reflectance (%) – Paint dependant ,Green (VoC,RC %) – Low, 30 complete and as directed by the departmental engineers. | 23.25 | Sq.m | 5,500 | ₹1,27,875 |
| 6 | Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level Using perforated sheets (10mm thick) etc., complete. | 163.8 | Sq.m | 994 | ₹1,62,817.2 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
Standard_GC.pdf
Additional Documents • 0.80 MB
Standard_Doc.pdf
Tender Documents • 0.23 MB
BOQ_865702.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .