| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.5 L+₹1.1 L (3.01%)Rejected-Finance 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹40.1 L+₹2.8 L (7.37%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹40.5 L+₹3.1 L (8.39%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹40.8 L+₹3.4 L (8.99%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
4 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVISION OF MT REST ROOM INCLUDING STAIRCASE FOR MT POOL GUARD ROOM AND OTHER SANCTIONED WORKS UNDER GE HADDO, PORT BLAIR
2021_MES_488616_1
8587/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
D a(i) and b (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹73,000
Yes
23 Dec 2021
16 Nov 2021
8 Dec 2021
16 Nov 2021
4 Dec 2021
29 Nov 2021
16 Nov 2021 - 23 Nov 2021
60 days
Amount
Excavation over areas not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for hardcore using broken stone or boulders of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for plain cement concrete (1:3:6 type C1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platforms and in shelves and the like complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc., also splays between floors and beams etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer including 3mm wall care putty after filling the cracks with filler complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of distemper oil emulsion over a coat of primer including 3mm wall care putty after filling the cracks with filler complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description with 3mm average thick wall care putty and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of cement based paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer after filling the cracks with filler complete all as specified and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for sand (river sand) filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Dismantling of wrought iron or mild steel work and structural steel work of any description not otherwise provided for complete
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, framing for cladding and glazing, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Grade E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 Grade E-165 complete all as specified and as directed.
M&L for rolled mild steel as in Stairs (framed) including stringers, threads, landing, balusters, hand rails etc. including cleats, brackets, etc. complete Fe 410 -W (Gde- E- 250)
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding not exc 5 cm long complete all as specified and as directed.
S&F mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, length of bolt exceeding 15 cm and not exceeding 30cm, dia of neck 25 mm complete all as specified and as directed.
S&F mild steel flat iron section as in support to eaves/ barge boards complete including necessary drilling holes, bolting etc confirming to Fe-290 Gde E-165
M&L for stainless steel hollow sections circular/square/rectangular in shape and any size and thickness, grade AISI-316 type (Austenitic anti-corrosive in nature) as in railings/grills/designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixed in any location complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
S&F pre-painted zinc coated aluminium sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminium sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F aluminium flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
Dismantling ceiling boards / wall cladding (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and grid complete all as specified and as directed.
M&L for 6mm thick x 150mm wide non-asbestos decorative planks (Shera planks) fixed to steel members with suitable screws/fasteners/nuts, bolts & washers and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for powder coated aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 4mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
Supply only 4.0 mm thick plain sheet glass, pin head type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 5.5mm thick plain sheet glass, pin head type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
S&F 12mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination complete all as specified and as directed.
S&F anodised aluminium grill of approved pattern, anodised powder coated, cut to required size and shape, fixed in position with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
Dismantling PVC (SWR)/ cast iron pipes of 110mm dia in any position along with all fittings and fixtures by removing at joints complete all as specified and as directed.
Dismantling PVC (SWR)/ cast iron pipes of 110mm dia in any position along with all fittings and fixtures by removing at joints complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 75 mm complete all as specified and as directed.
S&F PVC (SWR) branch piece, (Single Y) equal or unequal, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) branch piece, (Single Y) equal or unequal, diameter of outlet 75 mm complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
S&F switch piano, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 16 Amps, 240 volts complete all as specified and as directed.
S&F switch socket outlet, 5 pin, 6A, flush type, multipurpose, 240 volts complete all as specified and as directed.
S&F switch socket outlet, 2-in-1, 6 pin, 6A/16A, flush type, multipurpose, 240 volts complete all as specified and as directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F LED down light fixture of 18 Watts capacity, including 18 Watts LED lamp and testing complete all as specified and as directed. MAKE:CROMPTON GREAVES Cat part No. LCDSPLN-R-18-CDL or equivalent in HAVELLS/ WIPRO/
S&F Tube light fittings 2 feet mirror optical including all accessories and fixing arrangements complete all as specified and directed. Make : Philips Model No LED 48027/65/86 ultron/ CG Cat No LCL-14-CDL/Havells
S&F 25 watts LED building security light fittings IR 65 luminaire. Pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 including necessary fixing arrangements as per site requirements complete all as specified and directed. Make : C & S Model No. LTESSE25WLED/ Philips Model No. BRP020LEDHP/CW240V25/ CG Cat No - LSTO-25-CDL/ Havells/ Luker Cat Part No : LOHY210 WH
M&L for street light mounting bracket made up of 25mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F ceiling fan of metallic body, white colour, 1200mm sweep, AC 230 volts, heavy duty with down rod and canopies complete all as specified and as directed. MAKE: CG Model Aura Plus 5 Star/ Havells/ Usha/ Orient
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection, 8 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCB, SPN, "C" series, 240 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCB, SP, "C" series, 240 volts, 6-32 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/Schneider
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 50 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 70 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 95 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 120 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 240 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 300 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 400 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
NOTE for Item No. 87 to 93: 1. Cable test results like continuity test, megger test shall be submitted to Engr-in-charge before the cable is laid. 2. Necessary excavation and earth work shall be measured and paid separately under relevant items of this schedule.
M&L for HDPE DWC (Double wall corrugated) pipe of size 120mm (Outer diameter) x 103mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 77mm (Outer diameter) x 63mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for cable jointing kit for 1100V grade LT UG cable, 1100V grade, straight through, heat shrink type joint complete with jointing material and accessories suitable for 3½ core, 50 to 120 Sqmm XLPE armoured aluminium conductor cable complete all as specified and as directed.
M&L for cable jointing kit for 1100V grade LT UG cable, 1100V grade, straight through, heat shrink type joint complete with jointing material and accessories suitable for 3½ core, 150 to 240 Sqmm XLPE armoured aluminium conductor cable complete all as specified and as directed.
M&L for cable jointing kit for 1100V grade LT UG cable, 1100V grade, straight through, heat shrink type joint complete with jointing material and accessories suitable for 3½ core, 300 to 500 Sqmm XLPE armoured aluminium conductor cable complete all as specified and as directed.
Disconnecting old LT/HT cables of size 3.5 core 50Sqmm to 120Sqmm and draw out from the pipe or ground from CG power house to different feeder including relaying the same cable complete all as specified and as directed.
Disconnecting old LT/HT cables of size 3.5 core 150Sqmm to 500Sqmm and draw out from the pipe or ground from CG power house to different feeder including relaying the same cable complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Shifting of 2 pole structure (PCC Poles/ Swaged poles) by disconnecting all electrical connections, cables, Jumpers, GODs, Fuse units, Channels, angles, clamps including dismantling & breaking the PCC coping and necessary excavation from one place to required place including re-fixing the same channels, angles, clamps, GODs, Fuse units wit new units, new nuts, bolts and washers including and applying two coats of aluminium paint on surfaces 1m above the coping, applying two coats of synthetic enamel paint in zebra pattern with black and yellow colour combination upto 1mt ht above coping, writing MES No of poles complete including applying two coats of white wash on exposed concrete surface of coping duly preparing the surface including dismantling and taking out old damaged poles from the site complete all as specified Note: 1. Necessary excavation and earth work, shall be measured and paid separately under relevant items of this schedule. 2. Quoted rate shall deemed to include cost of breaking of PCC and removal of poles. 3. Quoted rate shall be deemed to include cost of transportation by crane and truck to shift the poles from one place another.
kakolil trade agencies
SKV Engineering
CARTWHEEL CONSTRUCTION
M/s Ramesh Lal
CHANDER SEKER ENTERPRISE
M/s K Moorthi
RELIANCE SALES AGENCY
M/s Bismi Builders & Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .