| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹3.1 Cr | L1 | Accepted-AOC Being Lowest and reasonable |
| 2 | L2₹3.8 Cr+₹68.0 L (21.8%)Rejected-Finance | ₹3.8 Cr+₹68.0 L (21.8%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹3.9 Cr+₹76.4 L (24.5%)Rejected-Finance CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹3.9 Cr+₹76.4 L (24.5%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹3.9 Cr+₹77.1 L (24.7%)Rejected-Finance | ₹3.9 Cr+₹77.1 L (24.7%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹4.2 Cr+₹1.0 Cr (32.9%)Rejected-Finance | ₹4.2 Cr+₹1.0 Cr (32.9%) | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
6 Jun 2022, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone, Spread Eagle Falls 793011
ADDN/ALTN AND SPECIAL REPAIRS TO STORAGE ACCN AT FSD PANITOLA UNDER GE DINJAN
2022_MES_521414_1
CESZ/DIN/ OF/2022-2023
Open Tender
Coal Works
Item Rate
365 days
GE Dinjan
As per NIT
2 documents required · 2 mandatory
₹2,000
Yes
GE Dinjan
₹4.2 L
Yes
18 Jul 2022
2 May 2022
8 Jun 2022
2 May 2022
6 Jun 2022
23 May 2022
3 May 2022 - 10 May 2022
Amount
Dismantling of plain or corrugated sheets in roofing any gauge and any thickness including Nainital or similar pattern complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling wall / ceiling board (fibre pulp insulation) or insulation boards any thickness including cover fillets complete all as specified and as directed.
Taking down the chowkhat or frames exc 1.5 sqm but n exc 4 sqm (without taking off shutters from the frame) each complete all as specified and as directed.
Taking down the chowkhat or frames n exc 1.5 sqm (without taking off shutters from the frame) each complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed nstonework and precast concrete articles complete all as specified and as directed.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile stenght of 550 Mpa as in roof covering/claddiing to wall , fixed with self tapping screws complete all as specified and directed
M&L prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridge, gutter etc fixed with self tapping screws complete all as specified and directed
S&F Joist, channel, angle, or tee sections fixed independentaly, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to grade Fe-410-w or E -250 quality A complete all as specified and directed
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 Gde-E-165 complete all as specified and directed
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hanging; also fastening conforming to grade Fe-410-W or E -250 quality A complete all as specified and directed
S&F framed work such as grills gratings, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed baluster; walk ways; railings; framed work or water tanks and similar work conforming to Fe 290 gde E 165 complete all as specified and directed
Supply and fixing Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
Supply and fixing Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long complete all as specified and directed
M&L Painting 2 coats of synthetic enamel paint on steel and iron surfaces of any description over 10 cm in width or girth including preparation of new surfaces and one coat of red oxide primer complete all as specified and directed
M&L for hardcore of broken stones of gauge n exc 63 mm , deposited, spread and levelled in layers n exc 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2(using 40mm graded stone aggregate) as in sub base complete all as specified and directed
M&L 25mm thick PCC(1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in flooring complete all as specified and directed
M&L Machine cut pre-polished kota stone slab flooring 20-25mm thick laid over 15mm thick cement screed bed of cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L Machine cut pre-polished kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over laid over 10mm thick cement screed bed of cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M &L Brickwork with subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar 1:4 in two layers (10+5mm)on fair faces of brick work or concrete surface of walls with top layer mixed with water proofing compound and finished even and smooth and without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surface of walls finished even and smooth without using extra cement complete all as specified and directed
Supply only liquid water proofing compound
Material and labour for Two Coats of Cement Base Paint over a coat of alkali resistant priming paint including preparation of newly plastered surfaces of wall complete all as specified and directed
Material and labour for Two Coats of Cement Base Paint including preparation of old surfaces of wall complete all as specified and directed
M&L for preparing the new plastered surfaces and applying three coats white wash on walls complete all as specified and directed
M&L for preparing the old surfaces and applying three coats white wash on walls including removal of existing treatment complete all as specified and directed
M&L for 75mm thick cement concrete 1:3:6 type-C2(using 40mm graded stone aggregate) as in plinth protection finished even and smooth without extra cement complete all as specified and directed
Reinforced cement concrete nominal mix 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed
Formwork to soffits of suspended slabs such as roof slab , floor slabs , landing ; and similar work not exc 200mm (horizontal or sloping) thick; rough finished surfaces of concrete flat complete all as specified and directed
M&L Mild steel TMT bars of Grade 500D 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars of Grade 500D 5mm dia and over upto and including 10mm dia cut to length, bent to shape required in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
Providing cement concrete 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edgescomplete all as specified and directed.
Supply and fix 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor complete all as specified and as directed.
Supply and fix 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S&F Stack clamps for 110mm bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed.
S&F for stainless steel wind operated (SS 304) turbo roof ventilator of size 610mm throat diameter having 42 Nos aluminium blade with FRP base plate of minimum thickness of 2mm and length 1600mm having approximate 10 kg weight with surface tissue complete all as specified and directed.
Taking down carefully aluminum/ copper point wiring (light, fan, socket or power) complete (excluding sunken box) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good to disturbed surfaces of walls, floors, ceilings etc. complete all as specified and as directed.
Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed.
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including 1.2mm thick mild steel terminal box with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for One light point controlled by one,one way switch complete all as specified and directed Note: Cutting chiseling shall be included in the rate quoted by the contractor.
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including 1.2mm thick mild steel terminal box with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one 5amps, 3/5pin socket outlet on same board with switches complete all as specified and directed Note: Cutting chiseling shall be included in the rate quoted by the contractor.
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including 1.2mm thick mild steel terminal box with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one 5amps, 3/5pin switch socket combination on independent board with switches complete all as specified and directed. Note: Cutting chiseling shall be included in the rate quoted by the contractor.
M & L for Concealed Point wiring with 2.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including 1.2mm thick mild steel terminal box with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one 15amps switch socket combination on independent board with switches complete all as specified and directed. Note: Cutting chiseling shall be included in the rate quoted by the contractor.
S & F Piano Switch single pole, one way flush type 6 Amp, 230 Volt complete all as specified and directed
S & F Switch Socket combination outlet flush type universal 2 in 1, 3 pin 6 Amps, 230 volt complete all as specified and directed
S & F Switch Socket combination outlet flush type universal 2 in 1, 6 Amps, 230 volt complete all as specified and directed
S & F Switch Socket combination outlet flush type universal 2 in 1, 6/16 Amps, 230 volt complete all as specified and directed
S & F Ceiling rose surface bakelite three terminals complete all as specified and directed
M & L for Concealed Sub main Wiring with two run of 10 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6 Sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note:(Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length)
Supply and fix epoxy powder coated Distribution Board, double door SPN 8 way for MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and directed
Supply and fix epoxy powder coated Distribution Board, double door TPN 4 way for MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and directed
S & F Single pole MCB, rupturing capacity 10 kA, 'C' curve , 6 to 32 Amp complete all as specified and directed.
S & F SPN MCB, rupturing capacity 10 kA, 'C' curve , 6 to 32 Amp complete all as specified and directed.
S & F TPN MCB, rupturing capacity 10 kA, 'C' curve , 6 to 32 Amp complete all as specified and directed.
S & F of LED batten with inbuilt driver made out of high quality aluminium extruded housing and aluminium heat sink for mounting LEDs, mercury free and decorative end caps with maximum power consumption 18 Watts with min system luminous efficiency lumen/watt > 100, CCT not less than 6500K and CRI > 80, operating voltage of 140-270 volts AC, P.F. > 0.90, 2.5 KV surge protection and current THD < 15% complete and including all other standard accessories as per manufacturer's instructions, internally pre-wired including connecting up with twin core 0.75 Sqmm copper conductor flexible wire/cable complete all as specified.
S & F new generation energy saving and environmental friendly long life LED highbay light with opal diffuser 80 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including lamp and PVC cable 1.5 Sqmm twin core for connection complete all as specified
S & F 10 watt LED Bulk head light fitting comprising of pressure die cast housing with acrylic diffuser (IP65 protection) including lamp complete all as specified and directed.
S & F new generation energy saving and environmental friendly long life LED security light 25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 25mm bore light grade GI pipe bend to shape, including MS clamp of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed
Materials and labour for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES schedule part-I, earth lead strip connected to indicated position including 7.5m long 15 mm bore GI pipe for earth wire protection and concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mesh including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil and testing on completion complete all as specified and as directed by Engineer in Charge.
Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in soft/ loose soil for foundation etc or for shaft, wells, manholes etc n exc 10 sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed.
Supply & laying bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
Supply and spreading sand cushioning for under ground cable protection with dry fine river sand complete all as specified and directed. Note: Punned thickness shall be measured and paid.
Returning ,filling in including spreading ,levelling watering and well ramming in soft/loose soil in layers n exc 25 cm thick complete all as specified and directed
Removing excavated soil not exceeding 50 m distance and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and directed .
M&L for UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core laid in trenches or fixed to walls including end termination fixing with lugs and nut bolts including taking down of old unserviceable cable complete all as specified and directed.
Fair cutting n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc. including rubbed finish and waste complete all as specified and directed
Supply & laying galvanized steel tubing "Light grade" of size 50 mm bore with GI fittings, like MS clamp and nuts bolts and washer etc. and laid in trenches/ under roads/ along pole/ wall for cable protection complete all as specified and directed
M&L semi concealed point wiring with multiple stranded color code copper conductor FRLSH, cable1.5 sqmm size 1100 V grade IS marked, including one run of single core stranded FRLSH copper conductor 1.5 sqmm PVC insulated cable as earth wire and connected to earth dolly drawn through and including stove enamelled steel conduit with all accessories/fittings, fixed/laid in concrete in wall/ceiling and quoted rates also includes white plate cover with flame flush mounting sunken metal suitable as per site requirement for mounting of flame proof switches/ sockets and push etc. all as directed for one light point controlled by one 16 amps one way switch complete all as specified and directed
M&L surface concealed point wiring with multiple stranded color code copper conductor FRLSH, cable 4sqmm size 1100 V grade IS marked, including one run of single core stranded FRLSH copper conductor 4 sqmm PVC insulated cable as earth wire and connected to earth dolly drawn through and including stove enamelled steel conduit with all accessories/fittings, fixed/laid in concrete in wall/ceiling and quoted rates also includes white plate cover with flame flush mounting sunken metal suitable as per site requirement for mounting of flame proof switches/ sockets and push etc. all as directed for One socket outlet point 16 A on independent board complete all as specified and directed
M&L for switch flame proof rotary type with termination box in LM6,16A, single pole 250V complete all as specified and directed. .
M&L for flame proof switch & plug combined in LM6 cable termination box in LM6, 16A,250V,2P+ earth. complete all as specified and directed.
M&L submain wiring with two single core PVC insulated (FRLSH) unsheathed multi stranded copper conductor cable confirming to IS-694-1990 of size 10 sqmm (nominal area) drawn through and including stove enamelled steel conduit with all accessories/fittings, fixed/laid concreate in wall/ceiling and continous PVC insulated single core copper conduit (FRLSH) stranded unsheathed 6 sqmm as earth wire complete all as specified and directed Note:(Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length)
S&F for flameproof weatherproof encloser for MCB DB/186 including gas cut O ring endless neoprene rubber gas kit IP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6, epoxy painted CMRI certified 63 amps AC supply 230 volts one incomming and 5 Nos outgoing including taking down old unserviceable DB complete all as specified and directed
Supply and fixing LED light fitting 2x18 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and directed
Supply and Fixing of Flameproof cum Waterproof LED high bay light fitting of 60W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed
Taking down and S&F test point terminal block made of gun metal or phosphorus bronze size 200x100x100 mm drilled and screwed including 3 nos 08 mm dia 25mm long hexagonal head screw complete all as specified and directed
Supply and spreading sand cushioning under LPG cylinders complete all as specified and directed.
S & F new generation energy saving and environmental friendly long life LED security light 25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 25mm bore light grade GI pipe bend to shape, including MS clamp of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .