Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC | ₹1.9 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹2.1 Cr+₹15.9 L (8.22%)Rejected-Finance | ₹2.1 Cr+₹15.9 L (8.22%) | 2 | Rejected-Finance Rejected other than L1 |
| 3 | 3₹2.1 Cr+₹22.0 L (11.4%)Rejected-Finance | ₹2.1 Cr+₹22.0 L (11.4%) | 3 | Rejected-Finance Rejected other than L1 |
| 4 | 4₹2.4 Cr+₹48.4 L (25.1%)Rejected-Finance OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹2.4 Cr+₹48.4 L (25.1%) | 4 | Rejected-Finance Rejected other than L1 |
| Sl No | Description | Qty | Unit | G and G Infratech Private Limited L4 | M/S SRI JAGDAMBE TRADERS L3 | YP INFRA L1 | B.K.ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Design, fabrication and erecting, Pre-engineered building (PEB) steel structure for Provision of Training Shed of size 12 m x36m with minimum 3.6m clear height i.e from top of FFL to bottom of truss etc and 0.45 mm base metal thickness, pre-painted camouflage pattern 0.5 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium Zinc alloy coated with painted having tensile strength of 550 Mpa as in roofing fixed with self-tapping screws and supply & fix for prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.60mm thick (AZ not less than 150) of colour as directed having tensile strength of 550Mpa as in ridge/vally gutter roof covering/cladding to wall, fixed with self tapping screw, (factory made valley gutter shape and size directed by Engineer-in-charge) include for the supply of bolts, gutter bolts, screws, washers, pipe nails, distance pieces, plugs, holder-bats (for pipes) and all jointing materials and also for all necessary cutting of gutters and pipes, drilling for bolts and jointing and fixing in position, down take pipe, downspout pipes and metal clamps,with brick work complete as shown on drawing, specification and as per Tender documents all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified: -
(i) Frame type Pre-Engineered Building
(ii) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2.
(iii) PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate incl form work upto plinth level.
(iv) RCC work M-30 in footing with plinth beam as per approved design and as per IS:9103.
(v) All necessary civil work for setting of the super structure layout, excavation, back filling, RCC foundation/ foundation work, Plinth beam, RCC four sitting platform in two sheds only and as shown on drg incl 16mm to 18mm thick pre-polished Udaipur green marble shall be provided on tread and riser over 20 mm thick screed bed in CM (1:3) incl bullnose finish.
(vi) Kotastone flooring , Plinth protection incl saucer drain, brick step, Plaster, SS railing complete civil work as specified.
Note : (i) Design parameters of PEB steel structure shall be as per PS clause No.24 to 30 of Tender.
(ii) Following items mentioned under srl no 1.01 to 1.08 here-in after shall also be included in lump sum rate quoted against Srl item No 1.00 of BOQ. | 3 | Each Job | 67,11,639.63 ₹2,01,34,918.89 | 63,66,700 ₹1,91,00,100 | 56,25,000 ₹1,68,75,000 Lowest | 57,00,000 ₹1,71,00,000 |
| 1.01All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein | |||||||
| 1.02Purlins and side girt members are galvanized with zinc coating of Z 275 gm/sqm shall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 | |||||||
| 1.03Permanently colour coated (camouflage patteren) high tensile steel sheet having minimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M | |||||||
| 1.04Kota stone flooring shall be 18 mm to 20 mm thick machine cut and and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm. Kota stone slab shall be laid over 20mm thick screed in CM (1:3) over 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shall achieve mirror finish surface. | |||||||
| 1.0575 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection including saucer drain as specified. | |||||||
| 1.0675 mm thick PCC 1:3:6 type C-1 as in plinth protection surface finished even and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided and same shall be filled with bitumen mastic (1:3) | |||||||
| 1.07PAINTING SCHEME FOR STRUCTURAL STEEL WORK: (a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns (b) Soap paint :- One coat of polyurethane paint -30 microns (c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) | |||||||
| 1.08Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface | |||||||
| 2.00 | Site Clearance in soft/loose soil complete all as specified and directed. | 2,268 | Square Metre | 50 ₹1,13,400 | 47 ₹1,06,596 | 100 ₹2,26,800 | 40 ₹90,720 Lowest |
Tender Value
₹2.2 Cr
EMD Value
₹2.9 L
Closing Date
30 Oct 2025, 6:00 pmClosed
Chief Engineer Lucknow Zone
HQ Chief Engineer Lucknow Zone, 17 Carriappa Marg, Lucknow-226002
PROVN OF TRG SHED AND PT SHED AT SRC FATEHGARH
2025_MES_714629_2
980107/FAT/E8 (LZ)
Open Tender
Civil Works
Lump-sum
270 days
FATEHGARH
AS PER NIT
8 documents required · 8 mandatory
₹2,000
AGE (I) FATEHGARH
₹2.9 L
18 Dec 2025
24 Sept 2025
8 Nov 2025
24 Sept 2025
30 Oct 2025
23 Oct 2025
Amount
Design, fabrication and erecting, Pre-engineered building (PEB) steel structure for Provision of Training Shed of size 12 m x36m with minimum 3.6m clear height i.e from top of FFL to bottom of truss etc and 0.45 mm base metal thickness, pre-painted camouflage pattern 0.5 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium Zinc alloy coated with painted having tensile strength of 550 Mpa as in roofing fixed with self-tapping screws and supply & fix for prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.60mm thick (AZ not less than 150) of colour as directed having tensile strength of 550Mpa as in ridge/vally gutter roof covering/cladding to wall, fixed with self tapping screw, (factory made valley gutter shape and size directed by Engineer-in-charge) include for the supply of bolts, gutter bolts, screws, washers, pipe nails, distance pieces, plugs, holder-bats (for pipes) and all jointing materials and also for all necessary cutting of gutters and pipes, drilling for bolts and jointing and fixing in position, down take pipe, downspout pipes and metal clamps,with brick work complete as shown on drawing, specification and as per Tender documents all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified: - (i) Frame type Pre-Engineered Building (ii) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2. (iii) PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate incl form work upto plinth level. (iv) RCC work M-30 in footing with plinth beam as per approved design and as per IS:9103. (v) All necessary civil work for setting of the super structure layout, excavation, back filling, RCC foundation/ foundation work, Plinth beam, RCC four sitting platform in two sheds only and as shown on drg incl 16mm to 18mm thick pre-polished Udaipur green marble shall be provided on tread and riser over 20 mm thick screed bed in CM (1:3) incl bullnose finish. (vi) Kotastone flooring , Plinth protection incl saucer drain, brick step, Plaster, SS railing complete civil work as specified. Note : (i) Design parameters of PEB steel structure shall be as per PS clause No.24 to 30 of Tender. (ii) Following items mentioned under srl no 1.01 to 1.08 here-in after shall also be included in lump sum rate quoted against Srl item No 1.00 of BOQ.
All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein
Purlins and side girt members are galvanized with zinc coating of Z 275 gm/sqm shall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3
Permanently colour coated (camouflage patteren) high tensile steel sheet having minimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M
Kota stone flooring shall be 18 mm to 20 mm thick machine cut and and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm. Kota stone slab shall be laid over 20mm thick screed in CM (1:3) over 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shall achieve mirror finish surface.
75 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection including saucer drain as specified.
75 mm thick PCC 1:3:6 type C-1 as in plinth protection surface finished even and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided and same shall be filled with bitumen mastic (1:3)
PAINTING SCHEME FOR STRUCTURAL STEEL WORK: (a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns (b) Soap paint :- One coat of polyurethane paint -30 microns (c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work)
Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface
Site Clearance in soft/loose soil complete all as specified and directed.
Surface excavation averaging 15 cm deep and getting out in Soft/loose Soil complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in lean concrete etc complete all as specifiedand directed
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. etc complete all as specified and directed.
M & L PCC 1:2:4 type B-1 (using 20mm graded stone aggt) as in kerb stone/Coping etc complete all as specified and directed
Removing excavated material (soil) to a distance exceeding 50m & depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed .
S&F rolled sections as in framing for cladding, gazing, frame/chowkhat and the like fixed with angle cleats and connecting plates, etc, conforming to Fe 415-W (Gde-E-165) quality A complete all as specified and directed.
S&F Mild steel, plain, black sheet 1.00mm thick in wall cladding, steel gates and similar work, cut to size, holes puched; including round headed screws, cloutnails or rivets and fixed to wood or steel flaming with plain 40mm lap joints with riveted or welded seams, including bending or turning up mitred angles, etc as required complete all as specified and directed.
Excavating in trenches not exc 1.5m wide and not exceeding 1.50 m in depth, for foundations, wells cesspit, manholes, drain, laying of pipes & cable etc and getting out in soft/loose complete all as specified and directed.
M & L PCC 1:3:6 Type C-2 (using 40 mm graded agg) as in surface channel and drain bad complete all as specified and directed.
Returning, filling in including spreading, leveving, watering and well ramming in layers n exc 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material exc 250 m but not exc 500 m and depositing where directed complete all as specified and directed.
M & L precast reinforced cement concrete M-25 grade as in cover slab of thickness 130 mm including reinforement as per manufacture instruction complete all as specified and directed.
M & L precast reinforced cement concrete M-25 grade as in 'U' shape drain of size 450mm width and av depth 600mm as per site condition and wall thickness 80 mm including reinforement as per manufacture instruction complete all as specified and directed.
Cutting existing CI/GI pipe line 40 mm dia for insertion of tee of size 50 x 50 x 40 mm for branch connection including excavation and earth work complete all as specified and directed.
Cutting existing CI/GI pipe line 40 mm dia for insertion of tee of size 40 x 40 x 25 mm for branch connection including excavation and earth work complete all as specified and directed.
M&L for steel water tubing 40 mm bore with screwed & socket joints, medium grade, galvanized (includ- ing short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches complete as per IS-1239 part-II all as specified and directed.
M&L for steel water tubing 25 mm bore with screwed & socket joints, medium grade, galvanized (includ- ing short lengths) with and includ- ing all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches complete as per IS-1239 part-II all as specified and directed.
S&F gun metal gate glove or gate valves, with Iron wheel head, screwed both ends for iron pipe ISI marked of 25mm bore GI pipe complete all as specified and directed.
M&L for steel water tubing 40 mm bore with screwed & socket joints, light grade, galvanized (includ- ing short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid across road, in trenches or across PCC drain, along electric pole complete as per IS-1239 part-II all as specified and directed.
Supply & laying sand cushioning to under ground cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured and paid.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core including dismantaling complete all as specified and directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core complete all as specified and directed.
M&L for DK thermoplastic cable junction boxes IP-66 with matric knockoutsfor calbe entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/6 Sqmm 4 core and fixed to the PSC/Steel poles by means of suitable size of clamps withnut and bolts with suitable busbar including all accessories. complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 1.5 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supplying & Laying reinforced pre cast flat ISI marked concrete cable protection cover of class LV Type 1 of flat size 250 mm x 150mm x 40mm , factory made, ISI marked, embossed with "LT ELECTRIC" on the top surface complete all as specified and directed
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level ) with top edge of the plate not less than 1.50m below normal ground level , connected to and including galvanized steel strip 25x4 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm pipe medium grade for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be re-done at without any extra cost by contractor.
M&L for surface mounted point wiring complete for One LED light/Building Security Light/Industrial Wall Mounting Fan/ controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, 1100 V grade multi-stranded copper conductor single core including ISI marked not less than 20 mm dia PVC rigid conduit medium grade fixed on surface/truss including pressed MS/GI sunken boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- Conduit shall be fixed on surface/ truss with necessary saddles where concelling of conduit is not fessible without any extra cost
Ditto all as item No.30 above but for 5 pin 6 Amp socket outlet on independent board complete
M&L for concealed/surface mounted point wiring complete for 16 Amp Switch controlled with PVC insulated and unsheathed FRLSH cable 2.5 Sqmm (nominal area) ISI marked, 1100 V grade multi-stranded copper conductor single core including ISI marked not less than 20 mm dia PVC rigid conduit medium grade fixed concealed in wall /truss/surface including pressed MS/GI sunken boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- Conduit shall be fixed on surface/ truss with necessary saddles where concelling of conduit is not fessible without any extra cost
Supply and fixing switch piano flush type single pole one way 6 Amp complete all as specified and directed.
Supply and fixing switch piano flush type single pole one way 16 Amp complete all as specified and directed.
Supply and fixing socket outlet 3 pin 6 Amp piano flush type complete all as specified and directed.
Supply and fixing socket outlet 3 pin 16 Amp piano flush type complete all as specified and directed.
S & F for Ceiling rose PVC polycarbonate isolated body 62.5 X 25mm with three terminal as per relevant IS complete as specified and directed.
S&F 20W LED batten surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block & fixing arrangments for fixing the light fitting complete all as specified and directed.
S&F 35W LED building security light fitting with Aliminium pressure die cast housing high purity PC fensel diffuser with silicon gasket for IP-66 protection, in built electronic driver duly wired upto terminal block & fixing arrangments for fixing the light fitting complete all as specified and directed.
S & F MCB DB vertical type 4-way VTPN sheet metal enclosure 415V with 200 Amp fully insulated starndard copper Busbar for each phase & sourrounded with neutral Bars & two common neutral bar, two earth bar incl cable ties for cable management suitable for housing MCCB/TPN 415 V as incommer IP-54 protection with metal doors all enclosed on strandard steel sheet flush mounted type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate complete all as specified & directed.
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 12 - way ISI marked all as specified and directed .
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 08 - way ISI marked all as specified and directed .
S&F MCB SPN 32 Amps 'B" series,10 KA 240 Volts ,AC ISI marked all as specified and directed .
S & F MCB SP 6 to 32 Amp rating 240V, 10 KA "C" curve & curent carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & directed
S&F MCCB 415 Volts AC, with 63 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified & directed.
S & F BLDC type Air circulator wall mounting fan 750 mm Sweep, single phase 230V AC, 1440 RPM, air delivery CMM, power consumption 250 watt, with string, 3 speed choice colour mate, 5 star rating & ISI marked alongwith complete accessories and connecting up the fan to ceiling rose incl PVC insulated 3 core 23/0.0076 copper cable & suitable size of flexible cord with plug top from ceiling rose to w/m fan motor not less than 0.5 m long for connection complete all as specified. Note:- Necessary Fan mounting arragnement on pillar /wall is deemed to include quoted rate.
M&L for submain wiring with two single core 4 sqmm copper conductor FRLSH, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. below ground level connecting to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixing with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified complete all as directed. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed
Supply, installation, testing and commissioning in replacement of outdoor cubical type LT feeder pillar box of size 0.90m x0.75m x 0.45m, factory made dust and vermin proof, double door (front and back openable by key from both side fancy locks), cubical type and duly compartmentalized and separation from each control switchgear, 415 volts, AC 50HZ IP-54 fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50x50x6mm thick, 50cm long leg grouted in PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed busbar chamber with copper bus bar suitable for 3 phase 4 wire AC including MCCB 100Amps, 4 pole, 415 volts, 16KA, 50Hz mounted on suitable bus bar insulator, 200 Amps rating suitable drilled and tapped for bolts with openable two part front and rear shutter, hinged front and rear panels and locking arrangement, bottom plates provided with the required numbers of cable entries/opening including cable glands and cable lugs with heat shrinkable PVC sleeving having RYB-B color code powder coated painting complete in bedded in PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate), not exceeding 0.45 Cum and complete all as specified and as directed.
B.K.ASSOCIATES (BID ID -3461100)
M/S SRI JAGDAMBE TRADERS (BID ID -3468633)
G and G Infratech Private Limited (BID ID -3463472)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tendersrc.pdf
Tender Documents • 3.30 MB
SRC_1.rar
Additional Documents • 2.90 MB
BOQ_820127.xls
BOQ • 2.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .