Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.8 LAccepted-AOC | L-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L-2₹29.5 L+₹1.7 L (6.30%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L-2 | Rejected-Finance Higher side quoted amount | |
| 3 | L-3₹29.8 L+₹2.1 L (7.44%)Rejected-Finance | L-3 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
28 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
SPL REPAIR TO BLDG NO. T-67, SPL REPAIR IN BLDG NO. T-02, T-04,T-05, T-06, T-07 and T-09 IN DEF and EMP COY, AND SPL REPAIR IN BLDG NO. T-01, T-02 and T-03 OF MI ROOM AT 8 MTN DIV HQ, AT KHUMBATHANG UNDER GE KHUMBATHANG
2022_MES_555259_1
80051/94/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
khumbathang
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
GE Khumbathang
₹69,000
30 Nov 2022
30 Sept 2022
29 Oct 2022
30 Sept 2022
28 Oct 2022
15 Oct 2022
Amount
Sch "A' Part-I B/R work:- Taking down Chowkhats or frames exc 1.5 Sqm but not exc. 4 sq. m each (without taking off shutters from the frames)
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M & L for cement concrete type D-2 1:4:8 (using 40mm aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for 40mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in sub base, flooring and surface finished rough all as specified and as directed.
M&L for 75mm thick cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in plinth protection, path, floors & paving including provision of necessary form work finishing the exposed surface even and smooth complete all as specified.
M & L for Cement Concrete , 1:2:4, type B1 using 20mm graded agg as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge.
M&L for glass dividing strips, 3 mm thick and 22mm wide
Demolition of brick or stone/block masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed by Engr-in-Charge.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness including cover fillets
S&F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed with nails to timber frame work as in walls complete all as specified and directed Engr-in-Charge.
Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position as in unframed work
M&L for Plain fillets of second class soft wood, sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge.
M&L for Plain fillets of second class soft wood, sectional area exceeding 6 Sqcm but not exceeding 13 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge.
M&L for Plain fillets of second class soft wood, sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or bradsin lipping complete all as specified and directed by Engr-in-Charge.
M&L for Plain fillets of second class soft wood, sectional area not exceeding 3 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or bradsin lipping complete all as specified and directed by Engr-in-Charge.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered)
M&L for rendering 10 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick otherthan fair face of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 3 coats of white wash on new plastered surfaces of wall including preparation of surfaces all as specified and as directed.
M&L for two coats of cement base paint over a cot of white wash on newly plastered surfaces of walls including preparation of surfaces and inclduing curing before and after applying each coat all as specified and as directed
M&L for two coats of plastic emulsion paint over a cot of primer on newly plastered surfaces of walls including preparation of surfaces all as specified and as directed
Hacking out broken glass (any thickness, size or description) from wooden/metal frames, glazed with putty or fixed with beads all as specified
S&F 4.8mm thick sheet glass, ordinary quality in squares n exc 0.5 sq.m in each pane glazing with oil putty complete all as specified and as directed.
S&F 5.5mm thick sheet glass, ordinary quality in squares n exc 0.5 sq.m in each pane glazing with oil putty or beads complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, roof coverings & wall
S&F 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers as in roofs, walls etc, with grade of zinc coating 275, complete all as specified and directed by Engr-in-Charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of specified colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
S&F Vitreous China squatting pan 'Orissa' pattern size 580 x 440 mm white, with integral foot rests with connection to drain and to flushing pipe antisyphonage pipe, PVC (SRW) 'P' trap including making good to floor complete all as specified and dirtected by Engr-in-Charge .
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Supply and laying of CPVC pipe 20mm dia SDR 11 & plain CPVC SDR11 fittings in tranches complete all as specified and directed by Engr-in-Charge.
S&F in repair 20mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms/20mm- 125gms). complete all as specified and directed by Engr-in-Charge.
Dismentling existing water tank of capacity exc.250 ltr to 500 ltr and removal to store yard all as specified and as directed.
S&F 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 02 nos 20mm dia tank nipple and 01 Nos 32mm dia drain plug complete all as specified in SSR Part I
M&L for 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
M&L for 2nd class hard wood rail and style 35mm thick Plain, framed, panelled shutters Plain framed, (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkats for doors.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F 100mm long butt hinges, medium weight, cold rolled mild steel
S&F 100mm long extruded aluminium alloy handles, fabricated type, anodised
M&L for preparation of new wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr-in-Charge.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
Demolition of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified.
S&F mild steel TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
All as per sre item No. 46 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc
M&L for RCC nominal mix, M-20 ( using 20 mm graded crushed stone aggregate ) as in Beams, cantilevers, bressummers, lintels over 1.5m span (Note:-TMT bars will be masured and paid sepretly)
M&L for preparation of new surfaces of steel of any description , over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge ..
M&L for preparation of old surfaces of steel of any description , over 10 cm in width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge ..
Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing serviceable like to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge
M&L for 25mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in sub base, flooring and surface finished rough all as specified and as directed.
M&L Non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for 3mm thick wall care putty on wall
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes, manhole etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Demolition and breaking up drain pipes 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
M & L for 100mm thick concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 150 mm bore, complete all as specified and directed by Engr-in-Charge.
S&F Soil-glazed stoneware drain pipes 150mm dia laid in trenches and jointed as specified
Sch "A' Part-II E/M work:- Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc.
M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover complete all as specified. (a) One light /fan/bell point/buzzer point exhaust fan controlled by one nos, one way 5/6 Amps switch.
All as per srl item No 63 here-in-before but One 3 pin socket outlet, 5 Amps, independent board, with cables 1.5 sq. mm size
S&F in repair Switch piano, flush type single pole, one way 5 Amp
S&F in repair Switch socket combination multipurpose, 5 Amp flush type
S&F in repair Ceiling rose 65x50mm, 2 to 3 terminal PVC/polycarbonate, isolated body
S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 63 here-in-before but with conductor of size 2.5 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 2.5 sqmm PVC insulated stranded copper conductor Cable.
S&F in repair Switch socket combination multipurpose, 3 pin 16 Amp flush type
Taking down existing LED tube lights 18/20 watt from the site and keeping in safe custody for re-fixing after completion of wiring and wall paneling.
S&F in repair wall mounted LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F in repair sheet metal powder coated versatile double door SPN distribution board, 8 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
S&F in repair MCB SPN 40 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repair MCB SP 6-32 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repair Bell, AC, 230 volts, single pole
S&F in repair bell push flush type single pole one way 5 amp.
M&L for Sub main wiring with two single core 6 sqmm multistranded copper conductor cable FERL, PVC insulated cable 1100 volts grade and 6 Sqmm as continous earthing drawing and including PVC casing and caping of suitable size with all acessories, complete including taking out of existing wiring all as specified. (Note:-Two runs of 06 Sqmm cable and one run of 06 Sqmm earth cable and one run of PVC casing caping will be measured as one running meter).
M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result complete including taking out of existing earthing all as specified.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 59,374.00 and any other reduction if any from quoted amount.
KASHMIR FAIR DEAL SERVICES
Ms/ ladakh technical services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .