Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.1 L+₹1.4 L (9.17%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | L3₹18.0 L+₹2.4 L (15.1%)Rejected-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | L3 | Rejected-Finance Rejected being other than L1 | |
| 4 | L4₹18.4 L+₹2.7 L (17.1%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-Finance Rejected being other than L1 | |
| 5 | L5₹19.3 L+₹3.7 L (23.4%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L5 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
26 May 2021, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF DG SETS AND CONNECTED WORKS AT TRANSIT CAMP CLH POWER HOUSE HALL OF FAME AND MES IB UNDER GE 865 EWS
2021_MES_439148_1
865/EWS(NIT-11)/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹80,000
Yes
20 Jun 2021
28 Apr 2021
28 May 2021
28 Apr 2021
26 May 2021
12 May 2021
Amount
Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engr-in-Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (4) Make of spare recommendation by auth service centre of manufacturer
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
M & L for changing /toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed. Make: Castrol/Veedol/Valoline
S&F in replacement of Oil filter element as per existing for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Mico/TVS
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
S&F in replacement of Air cleaner element (inner and outer) suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
S&F in replacement of Fuel filter elements (primary & secondary) for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
S&F in replacement of 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
S&F in replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets make: Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
S&F in replacement of Dynamo/alternator assy for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
380 KVA DG Set
63.5 KVA DG Set
S&F in replacement of auotmatic voltage regulator (AVR) 240 volt suitable for 380/250/63.5 KVA capacity of DG Set.
S&F in replacement of self starter for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
380 KVA DG Set
250 KVA DG Set
100 KVA DG Set
63.5 KVA DG set
35 KVA DG set
S&F in replacement of water pump assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
380 KVA DG Set
250 KVA DG Set
63.5 KVA DG Set
S&F in replacement of Turbo charger assy.for following capacity DG sets make cummins complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
380 KVA DG Set
63.5 KVA DG Set
S&F in replacement of Fan Hub assembely for following capacity DG set make cummins/Kirloskar/Greaves complete all as specified and directed by Engr-in-Charge.
100 KVA DG Set to 380 KVA DG Set
M&L for strip opening of alternator of 380 KVA capacity DG sets with following items :-
Rewinding of starter assy, complete with super enameled copper winding wire of appropriate size
Removning rotor and required mechaning work complete
Rewinding or replacement of CT coils/Field coil/Exiter coil complete
M&L for strip opening of alternator of 250 KVA capacity DG sets with following items :-
Rewinding of starter assy, complete with super enameled copper winding wire of appropriate size
Removning rotor and required mechaning work complete
Rewinding or replacement of CT coils/Field coil/Exiter coil complete
Note for Item Sr. No 14 and 15 here in above -: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
S&F in replacement of lub oil pump suitable for following Capacity DG Sets,make :Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
250 to 380 KVA DG Set
63.5 to 100 KVA DG Set
S&F in replacement of thermostate valve suitable for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
100 KVA to 380 KVA DG Set
35 KVA to 63.5 KVA DG Set
S&F in replacement of Oil seal front and rear suitable side for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
380 KVA DG Set
250 KVA DG Set
63.5 KVA DG Set to 100 KVA DG Set
S&F in replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Amron.all as specified and directed by Engr-in-Charge
M&L for calibration of injector unit including S&F in replacement O-Ring, pin roll, barrel, pin spring, washer and testing complete all as specified and as directed for 110 KVA DG to 500 KVA DG set Type TBD-2V6
M&L for calibration of FIP including S&F in replacement plunger, DV, goveronor wet O-Ring, pin roll,barrel, pin spring, washer and testing complete all as specified and as directed for 250 KVA DG set. Type TBD-2V6
M&L for calibration of FIP including S&F in replacement plunger, DV, goveronor wet O-Ring, pin roll,barrel, pin spring, washer and testing complete all as specified and as directed for 63.5 KVA DG set. Type TBD-2V6
M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assembly by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.
380 KVA DG Set
100 KVA DG Set
63.5 KVA DG Set
S&F in replacement of battery terminal for DG Sets complete all specified and as directed.
S&F in replacement of battery cable assy with copper conductor multistranded RED and BLACK colour 2 mtr long 21 sqmm for connection to self starter unit to Battery unit complete.
Supply & toping up of best quality anti freezing,Inhabitor Corrosion (Coolant ) liquid for DG set at varrious capacity and locations complete all as specified and directed. Make-Castrol/Veedol/Valoline
M & L for changing /toping up of best quality of engine oil 15W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed. Make-Castrol/Veedol/Valoline
Note :- Makes of spare parts to be replaced under this work and mentioend in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of DG sets and other equipments.
M/S BETONG CONSTRUCTION CO
Hitech Erectors Pvt. Ltd.
SUMEET TRADING CORPORATION
Horizon Construction Company
KONCHOK TSEWANG
Mangalam Trades
M/S AMCO INDUSTRIES AND EXPORT CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .