Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹42.9 L+₹3.0 L (7.45%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹44.0 L+₹4.0 L (10.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹49.6 L+₹9.7 L (24.2%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L4 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
28 Jan 2022, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8733/GWL/E8 REPAIR/ MAINT AND ARRESTING LEAKAGE OF WATER SUPPLY CI/DI/GI PIPE LINES, CONNECTED VALVES AND OTHER MISC WORKS AT MORAR CANTT GWALIOR UNDER GE GWALIOR
2021_MES_497918_1
8733/GWL/E8
Open Tender
Civil Works - Water Works
Works
180 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹96,000
Yes
8 Feb 2022
28 Dec 2021
31 Jan 2022
28 Dec 2021
28 Jan 2022
14 Jan 2022
Amount
M & L for rectification of joint leakage of CI/DI pipeline incl excavation, return filling, leadwool, lead pig, tyton Joint, 'D' Joint, MS Clamp and short piece of CI/DI pipes as required at site etc of size 300 to 400 mm dia pipe all as required and directed at site. Note:- Contractor will have to make arrangement of JCB & T&P for excavation, drain out/ pump out water. cutting of road/ path/culvert shall be make good as per original existing without any extra cost.
All as per item No. 01 above but of size 200 to 250 mm dia pipe.
All as per item No. 01 above but of size 100 to 150 mm dia pipe.
All as per item No. 01 above but of size 80 mm dia pipe.
Repair to leakage of existing GI pipe line 15 mm to 20 mm bore in any positions (joints, fittings etc) on wall ,roof, floor etc including replacement of GI fittings such as tee ,sockets elbows,unions nipples,reducers etc incl necessary excavation and earth work complete all as directed by Engineer in Charge. Note:- (i) GI Pipe replaced (If required) and Earth work for GI Pipe shall be measured and Paid separately under relevant items of this schedule.
All as per item No 05 above but GI Pipe of dia 25 mm to 50 mm dia
All as per item No 05 above but GI Pipe of dia 80 mm to 100 mm dia
M & L for Taking out Sluice valve of size 250 to 300 mm dia for Refacing, Regrinding, Opening all parts at site and replacement of UNSV parts like MS Spindle, U clamp check Nut, Brass Gate, gasket seel, glands, nut, bolts, washer etc and refixing complete after repair at site as directed by Engineer in Charge. Note :- Major parts like Spindle, Brass Gate, U Clamp Chek Nut etc measured & paid separately.
All as per item No. 08 above but Sluice valve of size 150 to 200 mm dia.
All as per item No. 08 above but Sluice valve of size 80 to100 mm dia.
Supply only MS Spindle as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as directed by Engineer in Charge.
All as per item No. 11 above but for sluice valve of size 150mm to 200mm dia.
All as per item No. 11 above but for sluice valve of size 80mm to 100mm dia.
Supply only Brass Gate as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as directed by Engineer in Charge.
All as per item No. 14 above but for repair to sluice valve of size 150mm to 200mm dia.
All as per item No. 14 above but for repair to sluice valve of size 80mm to 100mm dia.
Supply only CI U clamp (Gate Clamp) as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as directed by Engineer in Charge.
All as per item No. 17 above but for repair to sluice valve of size 150mm to 200mm dia.
All as per item No. 17 above but for repair to sluice valve of size 80mm to 100mm dia.
M & L for Taking out Foot Valve from UG sump in any position or any depth of size 200 mm dia for Refacing, Regrinding, Opening all parts at site and replacement of UNSV parts like MS Flap, Leather Gasket/flaps (Not less than 8mm thick) check Nut, gasket seel, nut, bolts, washer etc including welding and refixing complete after repair at site as directed by Engineer in Charge. Note :- T&P Requited for lifting Foot valves shall be provided by Contractor without any extra cost.
All as per item No. 20 above but of size 150 mm dia.
All as per item No. 20 above but of size 100 mm dia.
Supply & Laying in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site, including dismantling and taking out old unserviceable pipe line alongwith fittings from existing connections of size 100 mm dia complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
All as per item No. 23 above but of size 80 mm dia.
All as per item No. 23 above but of size 50mm dia.
All as per item No. 23 above but of size 40 mm dia.
All as per item No. 23 above but of size 25 mm dia.
Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors including dismantling existing steel tubing and connections fixed at any location all as directed of size 25 mm dia complete. Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe.
All as per item No. 28 above but of size 20 mm dia.
All as per item No. 28 above but of size 15 mm dia.
S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location of Size 50 mm dia all as directed
All as per item No. 31 above but of size 40 mm dia.
All as per item No. 31 above but of size 25 mm dia.
All as per item No. 31 above but of size 20 mm dia.
All as per item No. 31 above but of size 15 mm dia.
Supply and fix cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location of size 300 mm dia all as directed.
All as per item No. 36 above but of size 250 mm dia.
All as per item No. 36 above but of size 200 mm dia.
All as per item No. 36 above but of size 150 mm dia.
All as per item No. 36 above but of size 100 mm dia.
All as per item No. 36 above but of size 80 mm dia.
Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 200 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve all as directed.
Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve all as directed.
M&L for Construction of valve chambers of size 1.5x1.5 x1.2 internal dimentions with 150 mm thick PCC foundation 1:4:8 type D2 using 40 mm graded trap stone aggregate, 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 using 20 mm graded crushed trap stone aggregate valve chamber having coller frame size 1.5x1.5 x1.2 made of mild steel angles of size 50mm x 50mm x 6mm and cover made of 2.5 mm thick mild steel sheet framed by 40x40x5 mm MS angle having 02 nos cross 'X' supprt fixed with coller frame by mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of alluminium enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation, all as specified and directed by Engineer-in-Charge .
All as per item No. 44 above but of size 1.5M x 1.5M X 1.5M (Internal Size)
Supply and fix in replacement of old unserviceable Submersible Controller Fully automatic star delta startor, panel mounting with contactor and suitable thermal relay suitable for 17.5/22HP, 3 Phase , 415 volts, 50 Hz submersible pump set complete.
Supply and fix in replacement of old unserviceable Submersible Controller Fully automatic star delta startor, panel mounting with contactor and suitable thermal relay suitable for 15/12.5 HP, 3 Phase , 415 volts, 50 Hz submersible pump set complete.
Excavation in trenches through JCB not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in soft/loose soil. Note:- (i) Manual excavation may be carried out as when reqd as per direction of EIC. (ii) Any cable (Power cable/signal cable) damaged by JCB during excavation will be make good /repaired by the contractor with proper jointing kit without any addl cost.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm in in soft/loose soil.
Removing excavated surplus in soft/loose soil to a distance not exceeding 50M and depositing where directed and at a level not exceeding 1.5M above the starting point.
Material & Labour for PCC 1: 3: 6 type C1, using 20mm graded crushed trap stone aggregate & grouting in cement mortar 1:4 for making good road cutting.
Supply & installed Multi-Cavity water sanitiser/conditioning station with proportional dosing arrangement at zero discharge of the power free automatic system 100 ltr tank, cavities are completed with Lids. Attachment overflow valve, water inlet valve, outlet valve (for offline automated gravity flow), drain valve complete including dismantling old UNSV Gaseous Chlorinator complete and deposit in MES store yard (From BW No. 30 & BW No. 14). Note :- Required PVC pipe will be including for supply & fixing, provided by contractor at site for installation.
Supply only Chlorine tablets contained in plastic cylindrical sealed disposable sanitizer refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through for recommended dosing system complete with following operations, (a) Replacement Indication - Visual weight variation. (b) Water contact orifice design-sealed when dry, exposed upon immersion. (c) Operation type- Non contact, Non Inhalatory (d) Cylinder dia' 2.5 inches ± 0.5 inches. (e) Cylinder height - minmum 10 inches ± 0.5 inches. Make and model of Refill shall be as per existing sanitizer refill and all as directed by Engr-in-charge. Note- Use only for centrifugal pumps and sumps.
tanay enterprises
GURU KIRTH BUILDERS
M/s Shanti Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .