Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.0 LAccepted-AOC | 1 | Accepted-AOC Allotted |
Tender Value
₹39.7 L
EMD Value
₹79,440
Closing Date
12 Sept 2019, 3:00 pmClosed
Executive Engineer
Executive Engineer Public Heath Division No.2, Jind
Providing drinking water supply facility of 6 No. water works 1 No. tubewell based scheme under covered 10 No. villages Raichandwala Dhillowal Naguran Kheri Naguran Hasanpur Badhana Gohian Mandi Khurd Baniya Khera Retauli lifiting raw water Hansi br
2019_HRY_101896_1
Recall HO/51410/15052019
Open Tender
Civil Works
Works
180 days
JIND
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Yes
Executive Engineer, Public Health Division No.2
₹79,440
Yes
13 Feb 2020
5 Sept 2019
12 Sept 2019
5 Sept 2019
12 Sept 2019
5 Sept 2019
Amount
Part - I Supply, erection, testing and commissioning of 200 KVA/ 80 KW diesel generating set, noise control acoustic enclosure radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-) volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine. The rating should be at 1500 RPM (a) Diesel Engine (b) Alternator (c) Base Plate (d) Battery 24 V (e) 1x120 sq.mm 3.0 core XLPE Aluminum= 20 mtrs. (f ) Tools AMF Panel (a) Motorized change over switch 250 Amp.4 P with fuse base and HRC links 250 Amp. (b) Under voltage/over voltage relay= 2 No. 415 VAC (c) Engine start relay 24 VDC 1 No.(d) Electronic Timer 24 VDC 1 No. (e) Electronic Timer 24 VAC 2 No. (f) Auxiliary relay 220 VAC 2 No. (g) Auxiliary relay 220 VAC 3 No.(h) Metering set 415 VAC, 1 set (Amp. Meter, volt meter, ASS, VSS, Phase indicators, control fuse, frequency meter, CT’s).(i) Metering set 24 VDC (Amp. Meter, volt meter).(j) Over load protection for DC 1 No. (k) Battery charger 24 VDC (Blueron Make) (k) Battery charger 24 VDC (Blueron Make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (on/off) (o) Engine protection unit with audio visual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lamp for low lubricating oil pressure high coolant temperature, set running, load on, DC control on. Note: Control panel shall have the provision to provide auto manual failure panel (AMFP
Part - II Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum Four ) star rating duties directly coupled to Ac squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame. ii) Raw Water Pump at (P/Stn. at exst. W/W vill. Jamni) 1900 LPM, 20 Mtrs. Head
Supply and Fixing following CI D/F pipe and specials/Bell Mouth including cost of joining materials, laying, jointing, refilling inckuding making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the Department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water puping sets at water works in position, as per specification given in schedule No. II. For Pumping Machinery Detail of pipe and specials A) CI D/F bends, Reducers, tees, tapers, tail piece, blank flange etc.pipes excluding jointing material
B) CI D/F pipes 150 mm i/d
C) Bell Mouth 150 mm i/d
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 500X1200mm and 400mm deep having following accessories:- 1. Incomer switch 200 Amp. 2. Aluminum bus bar chamber of 300 Amp. Capacity. 3. Volt meter 100X100mm range 0 to 500 V (AE/KAPPA/L & T 4. Indicating lamp-one set. B) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm having following accessories:- A) Raw water pump sets for 1900 LPM x 20 M head = 2 Nos. (P/Stn. at exst. W/W vill. Jamni) (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB). (b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS & ASS 1 No. each of approved make (f) SPP 1 No. of approved make (g) Motor starter, star delta 2 Nos. for 1900 LPM x 20 M Head Motor (L&T Simens, AAB) (h) Capacity KVAR as per site requirement (i) Indicating Lamp-One Set ( j) Change over switch 63 Amp. = 1 No.
Supplying, erection and commissioning of 3 HP electric driven dewatering pumping set capacity 5m3 per hour 15 meter total head with wiring starter, switches and G.I. Pipes and special canvas hose and accessories as per specification in schedule no. II etc. complete in all respects.
Supply, erection, testing of standard make wiring of 2 nos. motors with underground system in PVC and flexible pipes copper wire size 10 Sq mm complete in all respects with accessories like thimble etc. complete in respects. (P/Stn. at exst. W/W vill. Jamni)
Supply, erection, testing and commissioning of 30 KVA/ 24 KW diesel generating set, noise control acoustic enclosure radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-) volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine. The rating should be at 1500 RPM (a) Diesel Engine (b) Alternator (c) Base Plate (d) Battery 24 V (e) 1x120 sq.mm 3.0 core XLPE Aluminum= 20 mtrs. (f ) Tools AMF Panel (a) Motorized change over switch 250 Amp. 4 P with fuse base and HRC links 250 Amp.(b) Under voltage/over voltage relay= 2 No. 415 VAC (c) Engine start relay 24 VDC 1 No. (d) Electronic Timer 24 VDC 1 No. (e) Electronic Timer 24 VAC 2 No. (f) Auxiliary relay 220 VAC 2 No. (h) Metering set 415 VAC, 1 set (Amp. Meter, volt meter, ASS, VSS, Phase indicators, control fuse, frequency meter, CT’s). (i) Metering set 24 VDC (Amp. Meter, volt meter). (j) Over load protection for DC 1 No. (k) Battery charger 24 VDC (Blueron Make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (on/off) (o) Engine protection unit with audio visual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lamp for low lubricating oil pressure high coolant temperature, set running, load on, DC control on. Note: Control panel shall have the provision to provide auto manual failure panel (AMFP
Supply, erection, testing of standard make wiring of 1 nos. panel boards from main switch to panel and wiring of panel with size 10 Sq. mm copper wire ISI marked complete in all respect with accessories like thimble etc. complete in respects.(P/Stn. at exst. W/W vill. Jamni)
Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications complete in respects.
Providing and fixing exhaust fans 18" i/d (450mm) complete with suitable GI sheet of approved make complete in respects.
Providing and fixing ceiling fan 1400 mm (56") with speed adjuster of reputed make (make Crompton, Usha, Bajaj, Orient) complete in respect..
Supply, erection, testing of reputed make CFL vapour light 100 watts with fitting and accessories complete in respects.
Stringing out DI (K-9) Pipes and specials castings along trenches and laying the same in ternches to correct, alignment and gradients including cartage from Divisional stores or nearest railway station to site of works and return of pieces to pipes to stores :- 300mm i/d (K-9)
Cutting DI pipes and specials and chipping or filing the surface to a uniform finish. 300mm i/d (K-9)
Jointing DI socketted pipes, valves and specials with rubber tyton joints fitted complete including cost of labour and tools etc. and tested complete. 300mm i/d (K-9)
Prov & fixing of various sizes DI specials as per ISI specification suitable for DI pipes.
Providing and fixing cast iron Kinetic air valves of size given below marked with IS : 14845 of Kirloskar including carriage, loading, unloading, stacking ,handling, re-handling etc. drilling, tapping, screwing in valves connections complete in all respect to the satisfaction of Engineer-in-Charge. 80mm i/d
Supplying fixing,jointing,testing,commissioning of DI Sluice Valve resilient Sheet P.N.1.6 as per NIT specifications on the pumping machinery and rising mains including cost of jointing material.(IVC,VAG, Kirloskar make) 300mm i/d
Supplying fixing,jointing,testing,commissioning of Scoure Valve resilient Sheet P.N.1.6 as per NIT specifications on the pumping machinery and rising mains including cost of jointing material.(IVC,VAG make) 300mm i/d
Supplying fixing,jointing,testing,commissioning of DI Swing Check type reflux(Non Return) valve P.N.1.6 as per NIT specifications on the pumping machinery and including cost of jointing material.(IVC,VAG make) 150 mm i/d
Providing & Fixing Flow Meter at Raw Water MPS near Hansi Branch & Various Water Works including specials and all types of jointing materials as per approved DNIT complete in all respect.
Part- III Operation and Maintenance of MPS (Dhatrath Jamni) as per schedule-IV for a period of 5 year (60 months) after three months of trial run period. (As per scope of work taken in DNIT). Operation and maintenance during defect liability period. (Operation Only)
1st year after defect liability period. (Operation & Maintenance)
2nd year after defect liability period. (Operation & Maintenance)
3rd year after defect liability period. (Operation & Maintenance)
4th year after defect liability period. (Operation & Maintenance)
Bidder Name
Amount
Virender Kumar,Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .