Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAdmitted-Finance | ₹1.8 L | L1 | Admitted-Finance |
| 2 | L2₹1.9 L+₹12,189.40 (6.91%)Admitted-Finance | ₹1.9 L+₹12,189.40 (6.91%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NITIN ENTERPRISES L1 | M/s Mohit Engineers L2 |
|---|---|---|---|---|---|
| 1.01 | (Sub-Head I) Visit charges to check the fault of existing DG Set at TE / BTSs sites i/c analysis of fault and making the detailed list of defects with the help of specialized manpower and estimation of the same etc. complete as required. a) Up to 25 KM from the District head quarter | 1 | Job | 2,500 ₹2,950 | 2,400 ₹2,832 Lowest |
| 1.02 | b) From 26 KM to 100 KM from the District head quarter | 1 | Job | 2,500 ₹2,950 Lowest | 2,700 ₹3,186 |
| 1.03 | Dismantling of existing DEA Set Open type/ silent canopy of following capacity & type i/c control panel with Power and control cable , Silencer and exhaust pipe , diesel tank , and associated fuel line and all other electrical accessories etc i/c placing the same in same bldg/ loading vehicle as per direction of Eng-In-charge i/c making good the damage etc. as reqd. (a) 25 KVA to 40 KVA | 1 | Job | 2,000 ₹2,360 Lowest | 4,000 ₹4,720 |
| 1.04 | Shifting & transportation of existing dismantled DG Set of following capacity and type i/c all accessories i/c loading with Crane /hydra/chain pully and safe transportation from one location to other location as given below i/c unloading with Crane /chain pully on existing CC Foundation /space as per direction of Eng-In-charge at new location etc etc. as required (a) 25 KVA to 40 KVA (up to 50 KM) | 1 | Job | 8,200 ₹9,676 Lowest | 8,500 ₹10,030 |
| 1.05 | Installation, testing , commissioning of Existing DEA set on existing foundation/surface with all accessories like Cubical type manual /AMF control panel i/c fixing of Silencer ,exhaust pipe , fuel tank , fuel line connections, control wiring from panel to engine i/c cutting, jointing, welding of flanges (if reqd) , nuts, bolts , i/c loading and assembling ,fixing the the DG Set i/c making good the damage etc. i/c One hour testing of DG set on exchange load etc as reqd (a) 25 KVA to 40 KVA | 1 | Job | 6,700 ₹7,906 | 6,600 ₹7,788 Lowest |
| 1.06 | Providing & Making of General Servicing of the following capacity existing E/A sets of different make and model installed at TE/BTS Sites i/c replacement of Lube oil, lube oil filter and diesel filter and cleaning of all parts of DG set like fuel line ,cooling system ,checking of all DG control wiring ,belt and drives for proper working as per manufacturer recommendations complete i/c Fare and labour charge i/c complete as reqd. - Note: (1) 1. Diesel for initial testing of DG set will be arranged by the contractor 2. The recovered black oil shall be given to contractor) (a) 10 to 20 KVA EA Set | 1 | Job | 7,000 ₹8,260 | 6,400 ₹7,552 Lowest |
| 1.07 | b) 25 to 40 KVA EA Set | 1 | Job | 7,500 ₹8,850 Lowest | 8,000 ₹9,440 |
| 1.08 | Repairing & General Servicing of the existing faulty radiator in existing DEA set up to 62.5 KVA by repairing of leakage and cleaning of copper tubes with help of cleaning gents, Dismantling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd. | 1 | Jobs | 4,500 ₹5,310 | 4,300 ₹5,074 Lowest |
| 1.09 | Repairing and Servicing of the 12 V self-starter of DEA set i/c dismantling, cleaning of self with petrol, greasing and oiling of bearing i/c replacement of carbon brush, solenoid coil, bentrx gear testing etc complete as reqd. | 1 | Job | 2,500 ₹2,950 Lowest | 2,700 ₹3,186 |
| 1.10 | Supplying and fixing of 12 Volts Maintenance free Battery of following capacity for E/A sets, i/c initial charging, battery terminals, transportation, testing, commissioning etc. complete as reqd.(Note: Battery should be of at least 24 months full replacement warranty/ Manufacturer warranty card with dealer stamp shall be submitted along with new battery) (a) 12 V, 88 AH | 2 | Nos. | 22,000 ₹25,960 | 21,000 ₹24,780 Lowest |
Tender Value
₹1.4 L
EMD Value
₹2,897
Closing Date
27 Jun 2026, 1:30 pmClosed
Executive Engineer (E)
BSNL, Electrical Division, Ghaziabad
Shifting of DG sets and Providing Servicing and replacement of Starting Battery for DG Sets at Various TE / BTS in OA Mathura (Additional Sites).
2026_BSNL_913087_1
33/EEE/BSNL/ED/GZB/26-27
Open Tender
Miscellaneous Works
Item Rate
60 days
Mathura
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Account Officer Cash, B.S.N.L, Ghaziabad
₹2,897
14 Jul 2026
15 Jun 2026
29 Jun 2026
15 Jun 2026
27 Jun 2026
15 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | (Sub-Head I) Visit charges to check the fault of existing DG Set at TE / BTSs sites i/c analysis of fault and making the detailed list of defects with the help of specialized manpower and estimation of the same etc. complete as required. a) Up to 25 KM from the District head quarter | 1 | Job | - | - |
| 1.02 | b) From 26 KM to 100 KM from the District head quarter | 1 | Job | - | - |
| 1.03 | Dismantling of existing DEA Set Open type/ silent canopy of following capacity & type i/c control panel with Power and control cable , Silencer and exhaust pipe , diesel tank , and associated fuel line and all other electrical accessories etc i/c placing the same in same bldg/ loading vehicle as per direction of Eng-In-charge i/c making good the damage etc. as reqd. (a) 25 KVA to 40 KVA | 1 | Job | - | - |
| 1.04 | Shifting & transportation of existing dismantled DG Set of following capacity and type i/c all accessories i/c loading with Crane /hydra/chain pully and safe transportation from one location to other location as given below i/c unloading with Crane /chain pully on existing CC Foundation /space as per direction of Eng-In-charge at new location etc etc. as required (a) 25 KVA to 40 KVA (up to 50 KM) | 1 | Job | - | - |
| 1.05 | Installation, testing , commissioning of Existing DEA set on existing foundation/surface with all accessories like Cubical type manual /AMF control panel i/c fixing of Silencer ,exhaust pipe , fuel tank , fuel line connections, control wiring from panel to engine i/c cutting, jointing, welding of flanges (if reqd) , nuts, bolts , i/c loading and assembling ,fixing the the DG Set i/c making good the damage etc. i/c One hour testing of DG set on exchange load etc as reqd (a) 25 KVA to 40 KVA | 1 | Job | - | - |
| 1.06 | Providing & Making of General Servicing of the following capacity existing E/A sets of different make and model installed at TE/BTS Sites i/c replacement of Lube oil, lube oil filter and diesel filter and cleaning of all parts of DG set like fuel line ,cooling system ,checking of all DG control wiring ,belt and drives for proper working as per manufacturer recommendations complete i/c Fare and labour charge i/c complete as reqd. - Note: (1) 1. Diesel for initial testing of DG set will be arranged by the contractor 2. The recovered black oil shall be given to contractor) (a) 10 to 20 KVA EA Set | 1 | Job | - | - |
| 1.07 | b) 25 to 40 KVA EA Set | 1 | Job | - | - |
| 1.08 | Repairing & General Servicing of the existing faulty radiator in existing DEA set up to 62.5 KVA by repairing of leakage and cleaning of copper tubes with help of cleaning gents, Dismantling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd. | 1 | Jobs | - | - |
| 1.09 | Repairing and Servicing of the 12 V self-starter of DEA set i/c dismantling, cleaning of self with petrol, greasing and oiling of bearing i/c replacement of carbon brush, solenoid coil, bentrx gear testing etc complete as reqd. | 1 | Job | - | - |
| 1.1 | Supplying and fixing of 12 Volts Maintenance free Battery of following capacity for E/A sets, i/c initial charging, battery terminals, transportation, testing, commissioning etc. complete as reqd.(Note: Battery should be of at least 24 months full replacement warranty/ Manufacturer warranty card with dealer stamp shall be submitted along with new battery) (a) 12 V, 88 AH | 2 | Nos. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.86 MB
BOQ_959582.xls
BOQ • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .