| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.4 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹82.0 L+₹4.6 L (5.95%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹89.4 L+₹12.0 L (15.5%)Rejected-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹89.9 L+₹12.5 L (16.1%)Rejected-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L4 | Rejected-AOC NOT BEING LOWEST | |
| 5 | L5₹92.4 L+₹15.1 L (19.5%)Rejected-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L5 | Rejected-AOC NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | GEPS PROJECTS L3 | Ashirwad Contractor and Supplier L4 | Sant Construction Co. L6 | Shiva Shakthi Electrical Enterprises L2 | RRK PROJECTS L7 | M/S N K POWER SYSTEMS AND PROJECTS L1 | Roy and Sons Infrastructures L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix Vertical TPN DB double door with 125 Amps 4 pole, 25 KA MCCB, 8 way, 415 Volts with insulated busbar assembly and isolated neutral busbar with IP 43 Protection complete all as specified and directed. | 1 | Each | 45,000 ₹45,000 | 25,500 ₹25,500 | 18,000 ₹18,000 | 18,000 ₹18,000 | 18,000 ₹18,000 | 14,999.73 ₹14,999.73 | 10,500 ₹10,500 Lowest |
| 2.00 | Supply and fix MCBs single pole, 240 volts, 10KA, 6 to 32 Amps C series complete all as specified and directed. | 24 | Each | 150 ₹3,600 Lowest | 240 ₹5,760 | 300 ₹7,200 | 270 ₹6,480 | 175 ₹4,200 | 299 ₹7,176 | 500 ₹12,000 |
| 3.00 | M & L sub main wiring with four single core PVC insulated cable with copper conductor FRLS multistranded 1100 volts grade 4x6 sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed.
Note : One run of earth continuity conductor,one run of PVC casing capping and four run of copper conductor together taken as one 'RM' for measuring unit length. | 85 | RM | 660 ₹56,100 | 690 ₹58,650 | 560 ₹47,600 | 360 ₹30,600 | 500 ₹42,500 | 299 ₹25,415 Lowest | 800 ₹68,000 |
| 4.00 | M & L sub main wiring with four single core PVC insulated cable with copper conductor FRLS multistranded 1100 volts grade 4x10 sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed.
Note : One run of earth continuity conductor,one run of PVC casing capping and four run of copper conductor together taken as one 'RM' for measuring unit length. | 55 | RM | 660 ₹36,300 | 1,250 ₹68,750 | 800 ₹44,000 | 540 ₹29,700 | 800 ₹44,000 | 499 ₹27,445 Lowest | 1,200 ₹66,000 |
| 5.00 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable and as directed. | 79 | Cum | 150 ₹11,850 | 120 ₹9,480 Lowest | 350 ₹27,650 | 270 ₹21,330 | 300 ₹23,700 | 139 ₹10,981 | 250 ₹19,750 |
| 6.00 | Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm . | 59 | Cum | 60 ₹3,540 | 75 ₹4,425 | 120 ₹7,080 | 54 ₹3,186 | 50 ₹2,950 | 49 ₹2,891 Lowest | 50 ₹2,950 |
| 7.00 | Removal of surplus soil (excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point . | 20 | Cum | 60 ₹1,200 | 75 ₹1,500 | 120 ₹2,400 | 54 ₹1,080 | 50 ₹1,000 | 49 ₹980 Lowest | 50 ₹1,000 |
| 8.00 | M & L for River sand, spread dry in trenches for Cushioning to cables in a layer of 8 cm thick before laying the cable in and second layer of 15 cm thick after laying the cable Complete all as specified and as directed. | 18 | Cum | 990 ₹17,820 | 850 ₹15,300 Lowest | 2,500 ₹45,000 | 999 ₹17,982 | 1,000 ₹18,000 | 999 ₹17,982 | 1,000 ₹18,000 |
| 9.00 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type I, flat, size 300mm x 180mm x 40mm laid in trenches as in protection of UG cables . | 770 | Each | 42 ₹32,340 | 48 ₹36,960 | 35 ₹26,950 Lowest | 45 ₹34,650 | 40 ₹30,800 | 39 ₹30,030 | 40 ₹30,800 |
| 10.00 | Supply and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid in trenches as in protection of UG cables all as specified and as directed. | 176 | Each | 39 ₹6,864 | 45 ₹7,920 | 30 ₹5,280 | 36 ₹6,336 | 35 ₹6,160 | 29 ₹5,104 Lowest | 30 ₹5,280 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
7 Aug 2025, 6:00 pmClosed
Col RAJENDER KUMAR
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST
PROVISION OF EXTERNAL ELETRIC SUPPLY INCLUDING STANDBY POWER SUPPLY FOR TESLA MRI MACHINE AT RADIOLOGY DEPTT AT CHAF UNDER GE(AF) BANGALORE
2025_MES_719359_1
87499CWEAFNBAN
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) BANGALORE
₹1.7 L
Yes
10 Oct 2025
9 Jul 2025
14 Aug 2025
10 Jul 2025
7 Aug 2025
31 Jul 2025
10 Jul 2025 - 23 Jul 2025
Amount
Supply and fix Vertical TPN DB double door with 125 Amps 4 pole, 25 KA MCCB, 8 way, 415 Volts with insulated busbar assembly and isolated neutral busbar with IP 43 Protection complete all as specified and directed.
Supply and fix MCBs single pole, 240 volts, 10KA, 6 to 32 Amps C series complete all as specified and directed.
M & L sub main wiring with four single core PVC insulated cable with copper conductor FRLS multistranded 1100 volts grade 4x6 sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and four run of copper conductor together taken as one 'RM' for measuring unit length.
M & L sub main wiring with four single core PVC insulated cable with copper conductor FRLS multistranded 1100 volts grade 4x10 sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and four run of copper conductor together taken as one 'RM' for measuring unit length.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm .
Removal of surplus soil (excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point .
M & L for River sand, spread dry in trenches for Cushioning to cables in a layer of 8 cm thick before laying the cable in and second layer of 15 cm thick after laying the cable Complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type I, flat, size 300mm x 180mm x 40mm laid in trenches as in protection of UG cables .
Supply and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid in trenches as in protection of UG cables all as specified and as directed.
Supply & Laying of HT 11 KV 3 core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 11000 volts complete all as specified and directed at site for the following cross sectional area 120 Sqmm x 3 Core.
M & L LT UG cable 3.5 core x 240 sq mm 1100 Volts grade XLPE insulated , flat steel armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for at site all as specified and as directed. Make : Polycab/Havells/Finoiex/CCI Notes for Item Nos 12 & 13: (a) Excavation earth work and sand cushioning brick protection and connected work etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed.
M & L for cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 120 sqmm to 185 Sqmm
M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 120 sqmm to 185 sqmm
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply, installation testing and commissioning of Outdoor Type Compact Sub – Station (CSS) having 3 way 11KV, 630A RMU, 250 KVA Copper Wound Dry type Transformer & LT Panel as per with facility for internal lighting, earthing , padlocks etc including making necessary cable termination box for more than one of Incoming / Out going LT UG cables as per site requirement and directed by Engineer in Charge, comprising the following equipments :- Make : ITE Gurgaon/ABB/ Schneider equivalent in Siemens.
(A) HT Switchgear (B) Transformer (C) LT Panel (D) Enclosure of CSS (E) Inter Connection and Earthing (F) Civil Works (G) Marking,Testing and commissioning
(A) HT Switchgear RMU-NON-Extensible 3 way, 11KV, CCV (2 isolators, 1 SF6 circuit breaker along with connected accessories etc.) Type: - Free Standing, Metal Clad, SF6 insulated Ringmaster with 2 no. 630A load breaking, Fault Breaking Switches and 630A T off SF6 Circuit breaker - 01 Nos a) Self Powered Relay, Type IDMT b) Ring Switches and T OFF SF6 circuit breaker with Integrated Earthing Switches c) Live Cable Indicator for Ring Switches – Provided d) Padlocking facility-Provided e) Shunt trip coil rating – 230V AC f) Padlocking facility Current Transformer – Cast resin Ratio: 50/5-5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA - 03 Nos Protection Numerical 2OC + 1EF Relay -01 Nos Indication Lamps VCB off / on / auto trip/ Trip circuit healthy/spring charge indication - 01 Set Metering Digital Ammeter - 01 Set. Digital Volt Meter - 01 No. Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control - 01 Set. MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel - 01 Set. Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry Including Termination Kit & Glands - 01 Set. Earth Bus –Aluminium - 01 Set.
(B) TRANSFORMER (Type : Cast Resin Dry Type) 250 KVA, 11/0.433 KV, Copper Wound Dry Type Cast Resin Step Down Transformer (Having Off Circuit Tap Links of +5% in steps of 2.5% each) with all standard fittings & accessories including Digital Type WTI with Alarm& trip contacts & RTD Sensors as per IS : 11171. Digital Volt Meter - 01 nos Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control - 01 Set. MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel - 01 Set. Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry Excluding Termination Kit & Glands - 01 Set. Earth Bus –Aluminium - 01 Set.
(C) LT PANEL LT Panel comprising of LV Side Incomer – MCCB 400 Amps, 36 KA, 4P with Adjustable type with microprocessor based release – 01 no. Outgoing – (a) MCCB 320Amps, 36 KA, 4P with Adjustable type with microprocessor based release – 01 no. (b) MCCB 250 A, 36 KA, 4P with Adjustable type with microprocessor based release – 01 no. (c) MCCB 160 A, 25 KA, 4P with Adjustable type with microprocessor based release – 02 nos Digital Volt Meter - 01 nos Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control - 01 Set. MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel - 01 Set. Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry Excluding Termination Kit & Glands - 01 Set. Earth Bus –Aluminium - 01 Set.
(D) ENCLOSURE OF CSS (ONE SET) Outdoor type enclosure having construction of galvanized sheet steel of thickness 3.15 mm for load bearing member and 1.5mm for non load bearing member with 4mm base frame. The enclosures shall have IP 65 degree of protection for HT & LT switchgear compartment and IP 23 degree of protection for transformer compartment. Each compartment will be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Separate switch operated bulket lamp+ hooter in transformer compartment. Transformer compartment door interlocked with breaker module including painting of complete set, Automatic sensor exhaust system and Auto thermal cut -off system with thermal setting complete.
(E) INTERCONNECTION AND EARTHING (ONE SET) Interconnection between HT switchgear and transformer using minimum size of 1Cx3x95 sqmm XLPE aluminum single core cable. Inter connection between transformer and LT switchgear using copper busbars. Internal earthing connections by using 50x6mm GI strips including transformer neutral. Note : (i) HT and LT compartments shall have degree of ingress protection IP 65 and that of transformer compartment shall be IP 23. (ii) The enclosure alongwith all inside compartment shall be painted with polyurethane painting of suitable thickness not less 150 micron for costal condition. (iii) Aluminium short pieces for 3 phases and neutral of suitable rating capacity with nuts, bolts and washers (set of two) shall be provided for by pass the ACBs when ACBs shall be out of order/under repair. Size shape and holes of short pipes shall match the system and ready to fix for operation.
(F) Civil works (i) All civil works including PCC plat form for Compact sub station size, and related to foundations, cable trench, including of panel and equipments including making good and existing structure of disturbed during installation and commissioning . The depth of the foundation and PCC as recommended by the manufacturer.The rate deemed to be included in quoted rate. (v) Make for all the equipments / materials incorporated in the work shall be as per the recommendation of the OEM. vi) All items of accessories,fittings,sundries,apparatus or labour whether specified in detail or not but which is necessary for successful commissioning of the compact sub station shall be part of installation and rate deemed to be included in quoted rate.
(G) Marking,Testing and commissioning (i) Letter painting shall be carried out at the front and rear side of the panels, transformer, VCBs including numbering of earthing etc specifing the full details and size of cables, feeder name, in appropriate size as directed by Engr-in- charge. (ii) Energizing of Compact sub station is after pre-commissioning of appropriate authority of MES channel as specified and directed by Engr-in- charge.
Manufacturers shall ensure to use same make Vaccum Interrupters & Vaccum Circuit breakers 4 Way (1 incoming , 3 out going ) outdoor type totally enclosed metal clad SF6 insulated Vaccum circuit breaker have following standard electrical & mechanical datas Vaccum circuit breaker module with Vaccum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy mechanism Incoming 11kV Fixed Manually operated Vaccum Circuit Breaker as Incomer 1 Vaccum circuit breaker module with Vaccum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy mechanism Vacuum circuit breaker 11kV, 630A, 21kA for 3-sec 1Microprocessor base Numerical type self-powered relays with O/C and E/F protection – CSDPR relay. 1Set of 3 Ring Core Protection CTs 2.5VA Class 5P10 - Ratio as per load requirement at site 1Cable bushings 400 series bolted 1Capacitive voltage indication fixed type VPIS 9-15 kV
Outgoing three Nos Vacuum circuit breaker 11kV, 630A, 21kA for 3-sec 1Microprocessor base Numerical type self powered relays with O/C and E/F protection – CSDPR relay. 1Set of 3 Ring Core Protection CTs 2.5VA Class 5P10 - Ratio as per load requirement at site. 1Cable bushings 400 series bolted 1Capacitive voltage indication fixed type VPIS 9-15 kV Air insulated module 11kV, 630A, 21kA for 3-sec 2 x 12 battery & battery charger Manual operating handle Coupling set
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS : 13364 complete with foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 250 KVA with outdoor AMF Panel with following detailed Specifications
(A) Diesel Engine Diesel Engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator IS:10001/ 10002,ISO 8528-1 , ambient temprature of 50°C ,50% RH & at 1000m above MSL, turbo charged, Governing class as per ISO 8528 part-V,engine capacity of 10% overload for one hour in every 12 Hours of continuous operation , shall have noise limit of <75dB at 1 metre complied with latest CPCB and Environmental norms. The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced.
(B) Protection to Genset i) Low lube oil pressure warning/shutdown (ii) High engine temp warning/shutdown (iii) Low coolant temp warning (iv) Radiator fan Belt Failure indication/shudown (v)Low/High battery voltage warning
(C) Alternator Synchronous alternator copper wounded rated 250 KVA, 415 Volts, 1500 RPM, 3 Phase 4 wire system , 50 Hz, AC Supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 1000 m MSL, brushless type, self exicited, continuous duty, sel regulated through AVR conforming to IS:4722 with Class F/H insulation as per IS: 13364 . The salient feature are as under : (i) Permanent lubricating bearing (ii) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (iii) Permissible unbalancing capability minimum 25% per phase
(D) AMF Panel (out door type) (i) Digital Amf controller with control relay such as mains faulier relay,under/over voltage protection relayl, under/over frequency relay,Reverse power protection relay (ii) switch gears such as MCCB,Power Contactor,Fuse (iii) Metering,control switches (vi)Weak battery warning (vii) Fail to start shutdown (viii) Cranking lockout
(D) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures Outdoor type suitable for 250 KVA capacity diesel Generator set duly fabricated of channel and CRCA sheet of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :-
(i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet (ii) Structure heavy duty rectangular MS box channel . (iii) Doors fabricated from MS CRCA sheet with air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks . (iv) Out side cover: Made out of CRCA sheet (v)Accustic insulation ( side &Top ) sound proofing minerla rock wool slab thickness 100mm of density 96Kg/m3 confirming to IS 8183 , covered by fire Resistant fiber tissue as per manufacturer recommandation (vi) Inside cover : CRCA perforated sheet powder coated (vii) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel (viii) 180 AH/12V - 02 Nos maintenace free batteries.
(E) FUEL TANK :- One No of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load, tank shall be fitted with in canopy and balace fuel tank to be kept outside of canopy with lock system as per manufacturer's design including the following:- (i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for drain oil. (iii) fuel strainer. (iv) Pipe for fuel. (v) Air vent. (vi) Mannually operated one no. fuel pump.
(F) NOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted this includes excavation and earth work for foundation, compaction, sub-base, base, RCC/PCC works all as directed by Engr-in-Charge (b)Tools shall be supplied with DG set unit as per manufacturer,s instructions and cost thereof shall be included in the price quoted . (c) DG Set shall be placed at the site directed by Eng-in-charge (d) Testing of DG set shall be done as per relavent clause of PS. (e) Make of DG Set with sound proof canopy - Krilosakar / Cummins India / Mahindra / Greaves - cotton / Jackson
Material & Labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 32 x 6 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate No 3 of SSR pt I, connected to DB/earthing test point including PCC chamber , RCC cover 50mm thick with 8 mm dia bars, protection pipe, funnel etc including excavation, earth work, disposal of surplus soil and earth strip protection pipe of GI 40 mm bore light grade upto 7.5 metre including testing on completion all as specified and as directed.
Shiva Shakthi Electrical Enterprises (BID ID -3386330)
GEPS PROJECTS (BID ID -3385306)
Ashirwad Contractor and Supplier (BID ID -3386017)
Roy and Sons Infrastructures (BID ID -3386531)
Sant Construction Co. (BID ID -3386127)
RRK PROJECTS (BID ID -3386493)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .