RequiredExperience with Government
RequiredAnnual Turnover Bid to RA enabled No Potable Water Purification System Reverse Osmosis Or UV Based ( 22 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certification for the product NA CE
RequiredWQA
RequiredNSF
RequiredNA Certification number and date - * Manufacturers ISO 9001:2015 ISO 9001:2015 1/7 Quality System Certifications Manufacturers Environment Management System Certifications NA ISO 14001:2004
RequiredNA Manufacturers Health and Safety Management System Certifications NA ISO 18001:2007
RequiredNA Performance Parameters Maximum Input Water TDS allowed to the system 1000 1000
Required2000
Required3000 Type of water purification technology RO+UV+UF RO+UV+UF Aavailability of sediment and activated carbon filter Yes * Operation Semi Automatic with External Auto Cut Off Fully automatic with auto cut off
RequiredSemi Automatic with External Auto Cut Off Ultraviolet (UV) LAMP Yes Yes Conformity to Standard for Ultraviolet system IS 14724 (latest) for water purification system with Ultraviolet disinfection IS 14724 (latest) for water purification system with Ultraviolet disinfection "Ultra Voilet (UV) Lamp power in watts (Hint put zero in case UV is not available)" 11 * Recovery at 27 degree Centigrade 25-35 25-35 Output Water Conforming standard IS 10500 (latest) * Filtration Capacity in liter/hour 50 50 Provision of Arsenic removal No Yes
RequiredNo Provision of Floride removal No Yes
RequiredNo Provision of Chloride removal No Yes
RequiredNo Alkaline filter No Yes
RequiredNo Storage tank Not available Inbuilt
RequiredNot available Type of out put NA Stainless Steel
RequiredClay 2/7 water Storage Tank Pot (Terracotta)
RequiredCopper
RequiredABS Food Grade
RequiredNA Storage Tank Capacity (storage tank external for higher capacity if required to be arranged by buyer) NA 8ltr
Required10ltr
Required12ltr
Required16ltr
Required25ltr
Required50ltr
RequiredStorage tank to be arranged by buyer
RequiredNA Minimum inlet pressure 0.3 KG/CM2 0.3 KG/CM2
Required0.6 KG/CM2
Required1 KG/CM2 Maximum inlet pressure 3.5 KG/CM2 * Maximum inlet temperature 35 DEGREE 35 DEGREE Digital display No No Real time TDS display No No Real time pH Display No No High pressure pump No Yes
RequiredNo Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes
RequiredNo Micron Filter Yes Yes
RequiredNo Total Dissolved Solids Removal Percentage from RO Membrane 25% 25%
Required50%
Required75%
Required90%
RequiredNA for UV only Particulate Filter Porosity 5 micron 5 micron
Required10 Micro
Required20 micron Pressure vessel Sand Filter No Yes
RequiredNo Pressure vessel carbon Filter No Yes
RequiredNo Pressure Vessel Dual Media Filter No Yes
RequiredNo Membrane Housing Yes Yes
RequiredNo Body of filter ABS Food grade ABS Food grade
RequiredMS Powder Coated
RequiredStainless Steel Auto cut Yes Yes Number of candles 3 3 Power supply 230 Volt single phase 230 Volt single phase Installation Type Wall mounted Wall mounted Miscellaneous Parameters Warranty in years including 1 1 3/7 replacement of filters Sediment & carbon twice a year) Warranty in years free replacement of machine 1 1
Required2
Required3
RequiredNA Antiscalant- where silica is up to 10 ppm/where Mica is up to 100 ppm No Yes
RequiredNo Availabilty of type test Test REPORT for Filtering Size of micron Particles Yes Yes TYPE Test certificate No and date for Filtering Size of micron Particles - * Name and Address of laboratory which conducted Test for Filtering Size of micron Particles: - * Availability of type Test Report on Microbial Efficacy from Govt/NABL/ilac Lab - * Type Test certificate No and date for Microbial Efficacy - * Name of the lab - * Availability of test report from Govt/NABL/ilac Lab (Design Evalution Report as per IS:14724 Yes Yes Test certificate No and date - * Name and Address of laboratory which conducted Test - * Availability of test report from Govt/NABL/ilac Lab regarding water quality as per IS:10500 Yes * Type Test certificate No and date - * Name and Address of laboratory which - * 4/7 conducted type Test regarding water quality Copies of certifications and reports to be given to buyer at time of supplies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Availability of toll free centers for customer support Yes Yes Installation and Commissioning inclusive in the scope of Supply* Yes Yes Availability of NABL Accredited Laboratory Facility with OEM No Yes
RequiredNo Name and Address of NABL Accredited lab with OEM
RequiredIf Not available put NA - * Inlet Pipe & Fitting from raw water scorces to water purification system to be arranged by buyer/consignee suitable pipe and fitting to be provided by seller up to 15 feet
Requiredto be arranged by buyer/consignee
RequiredNot applicable Pipe & Fitting from Out let to purified water tank To be arranged by buyer/consignee To be arranged by seller (upto 15ft)
RequiredTo be arranged by buyer consignee
RequiredNot applicable Electrical fitting and plug points To be arranged by buyer/consignee * Scope Civil Work if any required during installation All Civil work shall be responsibility of buyer * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents