Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.1 L+₹1.6 L (8.82%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹20.2 L+₹1.7 L (9.08%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹20.9 L+₹2.4 L (12.9%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹22.6 L+₹4.1 L (22.3%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
15 Jun 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPLACEMENT OF OLD WIRING AND ASSOCIATED ACCESSORIES IN CERTAIN QUARTERS AT SMA VARUNAPURI UNDER GE NW VASCO.
2021_MES_445771_1
85378/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹34,000
Yes
3 Nov 2021
25 May 2021
17 Jun 2021
25 May 2021
15 Jun 2021
8 Jun 2021
Amount
Taking down carefully unserviceable aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing material for taking credit(credits for above items should be made as per conditions separately) and making good disturbed surface of walls, floors etc complete all as specified and as directed.
Taking down unserviceable sub main wiring aluminium/ copper of any size/core/type including earth continuity conductor on teak wood or conduit and removing the materials /debris from site and making good the disturbed surface of wall etc to match with the original existing finish complete all as specified and as directed
Taking down unserviceable existing TPN DB/ LT Panel / Meter Box with 100 Amps MCCB of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Taking down unserviceable existing DB SPN 8 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M&L for point wiring complete with 1100 Volts grade PVC insulated and unsheathed multistranded copper conductor cable of 1.5 sqmm size confirming to IS 694 FR-LSH drawn through and including PVC casing and capping medium grade of size 25 mm , etc fixed on wall/ceiling including provision of pressed steel terminal box with 3 mm thick plastic laminated sheet top cover for housing switches ,sockets etc concealed on wall complete all as specified and as directed.for the following :-
(a) One light point controlled by one switch
(b) One fan/ exhaust fan point controlled by one switch and regulator
(c) One 3 pin socket, 5 Amps on the same board, with cables 1.5 sq. mm size
(d) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size
(e) One light point controlled by two 2-way switches, with cables 1.5 sqmm.
(f) One call bell controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm
M&L for point wiring complete with FR-LSH 1100 Volts grade, two runs of 2.5 sq mm copper cable through PVC casing and capping with one run of 2.5 sq mm PVC insulated and unsheathed multistranded copper conductor cable as earth continuity wire connected to common earth dolly complete all as specified and as directed
S&F Switch piano flush type single pole 5 Amps one way complete all as specified and as directed
S&F Piano type switch two way 230 volt 50 HZ AC supply complete all as specified and as directed
S&F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and as directed
S&F Switch socket combination 3 in 1,5 pin / 16A, flush type complete all as specified and as directed
S&F Bell push, flush type, 230 volt, 50 HZ ,AC supply complete all as specified and as directed
S&F Ding dong Bell, AC, 230 volts, single pole 50 HZ AC supply complete all as specified and as directed
S&F Ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body complete all as specified and as directed.
M & L for sub main wiring with 1100volt grade PVC insulated unsheathed multistranded cable with 02 runs of 06 sq mm copper conductor cable confirming to IS 694 FR-LSH drawn through and including rigid PVC conduit in Ivory/Grey colour medium grade etc fixed on wall/ceiling including provision of 01 run of 6.0 sq mm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 03 run of 06 sq mm and 01 run of PVC conduit shall be measured as one unit length.
S&F MCB DB, single pole and neutral with suitable rated bus bar double door 8 way 230 volt 50 HZ AC Supply complete all as specified and as directed.
S&F MCB SP 06 to 32 Amp 230 volts,50Hz,breaking capacity 10 KA complete all as specified and as directed
S&F RCCB Double pole, 30mA 25 Amps 230V 50Hz AC complete all as specified and as directed.
Supply, install, testing and commissioning of factory made LT panel wall mounted made out of CRCA sheet of 2 mm thick indoor type double door compartmentalised construction totally enclosed weather, dust and vermin proof with front opening hinged door locking arrangement 415 volt 3 phase 4 wires AC 50 Hz having aluminium bus bar for phases and the neutral insulated with PVC sleeves, suitable chamber for fixing single phase electric meter -5 Nos complete, and epoxy powder coat of spray paint over a coat of red oxide primer complete all as specified and directed. Note: Meter box/panel shall be fitted semi concealed on wall. INCOMING (a) Including provision of MCCB 415 volts 4 pole 25 KA breaking capcity fixed magnetic setting type of 100 Amps - 01 No (b) R -Y-B phase LED incating lamps - 03 Nos (c) 200 Amp TPN main aluminium bus bar OUTGOING (a) Including provision of MCB SP & N 32 Amps breaking capacity 10 KA 'C' Curve - 05 Nos (b) Space for mounting single phase energy meter - 05 Nos (c) Copper flexible wires of 6 Sqmm size for all feeders/meter connection.
Supply, install, testing and commissioning of factory made LT panel wall mounted made out of CRCA sheet of 2 mm thick indoor type double door compartmentalised construction totally enclosed weather, dust and vermin proof with front opening hinged door locking arrangement 415 volt 3 phase 4 wires AC 50 Hz having aluminium bus bar for phases and the neutral insulated with PVC sleeves, suitable chamber for fixing single phase electric meter -9 Nos complete, and epoxy powder coat of spray paint over a coat of red oxide primer complete all as specified and directed. Note: Meter box/panel shall be fitted semi concealed on wall. INCOMING (a) Including provision of MCCB 415 volts 4 pole 25 KA breaking capcity fixed magnetic setting type of 200 Amps - 01 No (b) R -Y-B phase LED incating lamps - 03 Nos (c) 200 Amp TPN main aluminium bus bar OUTGOING (a) Including provision of MCB SP & N 32 Amps breaking capacity 10 KA 'C' Curve - 09 Nos (b) Space for mounting single phase energy meter - 09 Nos (c) Copper flexible wires of 6 Sqmm size for all feeders/meter connection. Note for Item Nos.18 & 19:- (a) Electric Meters will be measured and paid separately
S & F LED Integrated battern T5 tube light fitting type 1x18/ 20 watt indoor decorative aluminium extruded type complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
S & F LED Integrated battern T5 tube light fitting type 1x9/10 watt indoor decorative aluminium extruded type complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed Notes for Item Nos.20 & 21: (a) Contractor shall submit original replacement warranty certificate stating defective light fittings shall be replaced without any extra cost for minimum two years after completion without any extra cost. (b) Contractor shall write CA No and date of completion on each LED fittings
S&F Deluxe stepped type electronic fan regulator flush 200 watt type on the phenolic laminated sheet complete all as specified and as directed
S&F Lamp holder, PVC/polycarbonated type with back plate suitable for batten fitting including provision of 9 W LED lamp -01 No complete all as specified and as directed
M & L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 m deep below the ground level with top to edge of the plate n. less than 1.5 m below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and dismantling the old earthing all directed including connections and testing on completion. Note: GI wire 4mm upto 7.5m length is deemed to be included under quoted rate
S&F Exhaust fan with aluminium louvers 230V single phase metallic body ,capacitor type -sweep size 300 mm connecting up including provision of necessary wall opening and connected cement works and cable from ceiling rose or connector to exhaust fan etc complete including taking down of old exhaust fan all as specified and as directed. Note: Old exhaust fan shall be deposited in store
M&L for removing and refixing of ceiling fan of sweep 1200 mm from its installed location servicing the fan by cleaning ,greasing ,oiling, painting with two coats of existing colour including replacement of worm out nut bolts , split pins , check nuts complete all as specified and directed
S&F 1 Phase KWH Meter, electronic type 5-30 Amps tamper proof Including PVC sealing and connecting cable on Meter panel in item No.18 & 19 above complete all as specified and as directed Notes: (a) Old Electric meter shall be deposited in MES store. (b) Contractor should submit old meter reading ,new meter initial reading and date of installation to office. (c) Contractor should write Qtr No for every meter
SHREE THATWAMASSY CONSTRUCTIONS PRIVATE LIMITED
S and G Constructions
Shree Ram Enterprises
Susheel Enterprises
U k Enterprises
OM SAI ELECTRICALS
pk janardhanan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .