AUTOMATION FOR TT GANTRY EXTENSION AND ETHANOL UNLOADING AT HASSAN TERMINAL
22000051-HD-10157
22000051-HD-10157
Open Tender
Hassan, Karnataka
₹0
Exempted
18 May 2022
26 Apr 2022
18 May 2022
18 May 2022
27 Apr 2022 - 11 May 2022
4 May 2022
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | SUPPLY OF MASS FLOW | SUPPLY OF MASS FLOW — SCOPE OF JOB INCLUDES DESIGN, FABRICATION AND SUPPLY OF MASS FLOW METER PACKAGE, SIZE, CLASS AS PER THE ATTACHED TECHNICAL SPECIFICATION AND DATA SHEET. | - | Each |
| 2 | ERECT OF 3" MASS FLOW | ERECT OF 3" MASS FLOW — ERECTION OF MASS FLOW METER: ERECTION OF MASS FLOW METER IN TT LOADING GANTRY FOR WHITE OIL MEETING THE REQUIREMENT OF HPCL ENGINEER-IN-CHARGE. | - | Each |
| 3 | SUPPLY OF 2" MFM WITH 2" | SUPPLY OF 2" MFM WITH 2" — SCOPE OF JOB INCLUDES DESIGN, FABRICATION AND SUPPLY OF MASS FLOW METER PACKAGE, SIZE, CLASS AS PER THE ATTACHED TECHNICAL SPECIFICATION AND DATA SHEET. | - | Each |
| 4 | ERECT OF 2" MASS FLOW | ERECT OF 2" MASS FLOW — INSTALLATION OF 2 INCH MASS FLOW METER AT NEW LOCATION BENEATH THE PLATFORM, JOB INCLUDES SHIFTING OF 2 INCH MASS FLOW METER FROM STACKED AREA A WITHIN THE HPCL PREMISES, PROVIDING ALL REQUIRED NON SPARKING TOOLS AND TACKLES ETC, AS PER REQUIREMENTS TO COMPLETE THE WORK IN ALL RESPECTS AS PER INSTRUCTIONS OF ENGINEER IN CHARGE, ADEQUATE CARE SHALL BE TAKEN BY THE CONTRACTOR NOT TO DAMAGE THE EXISTING EQUIPMENT/PIPING SYSTEM WHILE DISMANTLING, THE CONTRACTOR SHALL RECTIFY ANY DAMAGE CAUSED WITHOUT ANY IMPLICATION TO THE OWNER, JOB ALSO INCLUDING SUPPLY OF SPIRAL WOUND GASKETS, STUD AND BOLTS AS PER THE TECHNICAL SPECIFICATION. | - | Each |
| 5 | TERMINAL SERVER | TERMINAL SERVER — PART NAME:REDUNDANT TERMINAL SERVER; PART MATERIAL:N/A; PART RATING:N/A; PART NUMBER:N/A; MANUFACTURER:N/A; ADDITIONAL INFORMATION:WITH DUAL LAN AND DUAL HOST REDUNDANCY; AS PER APPROVED DESIGN AND APPROVED DATASHEET | - | Set |
| 6 | ERECTION OF TERMINAL | ERECTION OF TERMINAL — ERECTION OF REDUNDANT TERMINAL SERVER AS PER APPROVED DRAWING. SCOPE INCLUDES DISMANTLING OF OLD ITEMS AND STORAGE OF SAME AS PER INSTRUCTION OF SITE IN CHARGE. | - | Set |
| 7 | TESTING & COMMNG OF | TESTING & COMMNG OF — TESTING, COMMISSIONING OF REDUNDANT TERMINAL SERVERS AS PER APPROVED FDS AND MEETING THE REQUIREMENT OF HPCL EIC. | - | Set |
| 8 | SUPPLY OF 4" DCV | SUPPLY OF 4" DCV — VALVE,CONTROL; MANUFACTURER:N/A; MODEL:N/A; TYPE:DIAPHRAGM,DIGITAL; MAT SPEC,BODY:N/A; PRESSURE DESIGNATION:30 TO 300 LPM; SPEC,LEAKAGE:N/A; TYPE,ACTUATOR:N/A; PRESSURE,AIR SUPPLY:N/A; SERVICE:N/A; FLOW COEFFICIENT (CV):N/A; SIZE:40 MM; EXPLOSION PROOF CLASS 1, GROUP II A AND II B, T3 AND WEATHER PROOF TO IP65 FOR SECONDARY PRODUCT. | - | Each |
| 9 | ERECTION & COMMNG | ERECTION & COMMNG — ERECTION OF 4 INCH DIRECTIONAL CONTROL VALVES AS PER APPROVED DRAWING. SCOPE INCLUDES DISMANTLING OF OLD ITEMS AND STORAGE OF SAME AS PER INSTRUCTION OF SITE IN CHARGE. | - | Each |
| 10 | SUPPLY OF 2" DCV | SUPPLY OF 2" DCV — VALVE,CONTROL; MANUFACTURER:N/A; MODEL:N/A; TYPE:DIAPHRAGM,DIGITAL; MAT SPEC,BODY:N/A; PRESSURE DESIGNATION:30 TO 300 LPM; SPEC,LEAKAGE:N/A; TYPE,ACTUATOR:N/A; PRESSURE,AIR SUPPLY:N/A; SERVICE:N/A; FLOW COEFFICIENT (CV):N/A; SIZE:40 MM; EXPLOSION PROOF CLASS 1, GROUP II A AND II B, T3 AND WEATHER PROOF TO IP65 FOR SECONDARY PRODUCT. | - | Each |