Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Lowest Bid L1 rank is competitive and reasonable during Scrutiny amongst bidders |
| 2 | L2₹1.6 Cr+₹15.2 L (10.6%)Rejected-AOC N A | NEW DELHI | DELHI | 110001 | ₹1.6 Cr+₹15.2 L (10.6%) | L2 | Rejected-AOC Being not lowest |
| 3 | L3₹1.7 Cr+₹29.4 L (20.4%)Rejected-AOC B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹1.7 Cr+₹29.4 L (20.4%) | L3 | Rejected-AOC Being not lowest |
| 4 | L4₹1.8 Cr+₹37.5 L (26.1%)Rejected-AOC SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | ₹1.8 Cr+₹37.5 L (26.1%) | L4 | Rejected-AOC Being not lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.6 L
Closing Date
12 Oct 2024, 6:00 pmClosed
CWE
CWE AF BAMRAULI
IMPROVEMENT UPGRADATION TO MD ACCN AT AF STATION BIHTA
2024_MES_667178_2
87394/E8
Open Tender
Civil Works
Item Rate
365 days
BIHTA
Class B Category a i and other criteria as per Tender Doc and NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) BIHTA
₹2.6 L
Yes
20 Nov 2024
20 Sept 2024
15 Oct 2024
20 Sept 2024
12 Oct 2024
28 Sept 2024
20 Sept 2024 - 23 Sept 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. Note : - All demolished items/ debris to be removed out side of MoD land.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. Note : - All demolished items/ debris to be removed out side of MoD land.
Demolition of cement concrete (reinforced) of any description and in any position provided complete all as specified and directed. Note : - All demolished items/ debris to be removed out side of MoD land.
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar/cement mortar including all quoins, arches, pillars, etc complete all as specified and directed by Engineer-in-Charge.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds etc complete all as specified and as directed. Note : - All demolished items/ debris to be removed out side of MoD land.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay PCC padding complete all as specified and directed by Engineer-in-Charge. Note : - All demolished items/ debris to be removed out side of MoD land.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks and removing to store (capacity exc 250 & n exc 500 ltrs) all as specified and directed.
Dismantling existing cast iron soil vent pipe of 100 mm internal dia, fixed to wall or laid in trenches incl all fitting & accessories complete all as specified and directed by Engineer-in-Charge.
Dismantling existing cast iron soil vent pipe of 75 mm internal dia, fixed to wall or laid in trenches incl all fitting & accessories complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site complete all as specified and directed
Taking down or up 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal complete all as specified and directed
Taking down or up 20 mm bore galvanised iron tubing and connection including cleaning for refixing or removal complete all as specified and directed.
Taking down cement plaster on brick or stone walls & chajja including raking out joint, hacking for key,scrubbing down with water etc. complete all as specified and directed
Taking down rain water pipes (any size or pattern) ,including all fittings complete all as specified and directed
Excavation in trenches in soft / loose soil n exc 1.5 Mtr wide and n.exc 1.5 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes,pole etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified & directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables/pipes etc. are laid, jointed & tested complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for providing cement concrete type E-2, 1:5:10 (40 mm graded aggregate) as in foundations, filling and mass concrete, filling of sunken portion etc complete all as directed.
M & L 75mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base of floor and hardstanding and other similar work complete all as specified and directed.
M & L for PCC 1:3:6 type C-0 using 12.5mm crushed stone aggregate as in filling back side of pressed steel door/window frames complete all as specified and directed.
M & L PCC 1:3:6 type C-1 using 20mm crushed stone aggregate as in plinth protection complete all as specified and directed.
M&L for providing PCC type B-1, 1:3:6 (20 mm graded aggregate) for providing cement concrete as levelling and roof kerbs or mud stop, including finishing the surface with grinder to receive the acrylic based water proofing material, rounded or chamfered on edge) etc complete all as specified and directed.
M & L 40mm thick plain cement concrete type B-1, 1:2:4 (using 20 mm graded aggregate) provide on floor complete all as specified and directed
M & L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in roof curves, chajja of window/ ventilator or mud stops, rounded or chamferred on top of chajja and side edges of surfaces upto the height of 7 mtr etc complete all as specified and directed. Note : (the rate is deemed to be inclusive of scafolding/ formwork)
M & L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in kerb / benching / coping like including weathering slightly rounded or chamfered angle and with and including necessary form work as required for finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
M & L for providing reinforcement cement concrete type B-, 1:2:4 (20 mm graded aggregate) as in chajja, balcony, projection, shelf etc including necessary form work complete all as specified and directed.
M & L for mild steel TMT 10 mm dia and over cut to length, bent to shape required, including cranking and including mild steel wire (annealed) not less than 0.9 mm dia or securing ith clips complete all as specified and directed.
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:6 cement mortar complete all as specified and directed by Engineer-in-Charge.
M & L for 60 mm thick machine pressed precast concrete interlocking tiles/ paver block of any size & shape with grey cement and pigment to IS:15658-2006 ,compressive strength not less than 350 Kg/sq.cm (M-35) laying over 50 mm thick sand cushion(filling) and joints filled with sand complete all as specified and directed. NOTE: (i) Manufacturer’s test certificate of Interlocking tiles shall be produced on each/every lots before making payment. (ii) Colour and shape shall be decided and approved by GE. (iii) S & F of sand filling shall be measured and paid sepeatly in respective item.
M & L for sand filling under floor, hardstanding including watering and consolidation complete complete all as specified and directed.
M & L for 5 mm thick rendering in CM (1:3) on ceiling surfaces of finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for 15 mm thick rendering in CM (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound @3% of cement wt. (WPC will be measured and paid separately). complete all as specified and directed.
M & L for 15 mm thick rendering in CM (1:6) on vertical surfaces of brick walls finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for GI pipe medium grade with all fittings laid in trenches 25mm bore medium grade ISI Marked of following sizes with all fittings complete incl taking out old exiting GI pipe complete all as specified and as directed by Engineer-in-Charge.
S & F GI tubing bore of pipe 15 mm medium grade with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified and directed by Engineer-in-Charge.
S & F GI tubing bore of pipe 20 mm medium grade with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Screwing/ Welding of existing steel tubing of size 25 mm for additions or lengthening screw on pipe to from connectors complete all as specified and directed.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks three layer vergin plastic product with all fittings of GI (cylindrical vertical with closed top) hoilsted and fixed in position complete all as specified and directed.
Supply & fixed in repairs 20 mm bore brass ball valves, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed.
Supply & fixed in repair 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and water tank nipal fixed complete all as specified and directed by Engineer-in-Charge.
S & F Gun metal gate valve 25 mm ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surface such as skirtings, dodos set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles complete all as specified and directed.
M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L glazed ceramic coloured tiles of approved quality ISI marked (450 x 300 x 7 mm thick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface complete all as specified and directed by Engineer-in-Charge.
M & L for 15-17 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms (including a hole of gas pipe) and like incl 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M & L for 15-17 mm thick Granite (of any type) work (table rubbed and polished) for wall lining, cooking platforms (including a hole of gas pipe) over 12 mm thick cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab 20 mm thick (pre polished) laid and jointed with grey cement slurry mixed with pigments to match the shade of stone in treads, landings of stair case over and incl 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab 20-25 mm thick (pre polished) laid and jointed with grey cement slurry mixed with pigments to match the shade of stone in skirting and risers of stair case over and incl 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Strucking of existing PCC floor surface 5 to 10 mm deep picking, sweeping clean and washing down with water to receive cement mortar for tiling complete all as specified and directed.
M & L for preparation of sunken portion (floor) incl demolation of existing PCC,WC,P/S Trap and removing the material out side MD land with following additional work as under complete all as specified and directed: (a) preparation of RCC surface of sunken slab (Floor) by brushing and cleaning thoroughly with water. (b) application of two coats of poly urethene based chemical treatment ( as per manufacturer's instruction DR fixit/FOSROC/CICO/STP). (c) 15mm thick 1:4 CM plaster over chemical coating inc finishing the surface even & smooth without using extra cement all as specified. NOTE:- Continuity with cementitious water treatment beyond sunken portion in toilet shall be maintained.
M & L for preparation of sunken portion (floor) incl demolation of existing PCC,WC,P/S Trap and removing the material out side MD land with following additional work as under complete all as specified and directed: (a) preparation of RCC surface of sunken slab (side) by brushing and cleaning thoroughly with water. (b) application of two coats of poly urethene based chemical treatment ( as per manufacturer's instruction DR fixit/FOSROC/CICO/STP). (c) 15mm thick 1:4 CM plaster over chemical coating inc finishing the surface even & smooth without using extra cement all as specified. NOTE:- Continuity with cementitious water treatment beyond sunken portion in toilet shall be maintained.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roof or terrace, cleaning of grouting with cement and sand slurry 1:3 complete all as specified and directed.
M & L for cutting grooves in brick wall 75 mm wide and 65 mm deep & shaping horizontal face of groove with cement, complete all as specified and directed
M&L for rendering or bedding layer 15 mm thick in cement mortor 1:3 over concrete surface of roof, mixed with water proofing compound 2% wt of cement including finishing surface even and fair without using extra cement complete all as specified and directed (NOTE :- WPC shall be measured and paid seperatelly).
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new surface and applyig hot bitumen of 85/25 grade conforming to IS 702@ 1.2 Kg/Sqm over and including primed surface of roof slab @ 0.40 Kg/Sqm complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighting 3.60kg/Sqm and minimum 3 mm thick reinforced with polyester non fabric (Weight not less than 150 gm/Sqm) laid on primed surface by forced application complete all as specified.
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed.
S & F in repair chromium plated fancy type angular stop cock, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed one ends for iron pipes 15mm bore complete all as specified and directed by Engineer-in-Charge.
S & F in repair chromium plated concealed type stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes 15mm bore complete all as specified and directed by Engineer-in-Charge.
S & F in repair Chromium plated 125 mm long shower rose with or without swivel joints, any size, incl fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S & F in repair 15 mm bore chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality complete all as specified and directed by Engineer-in-Charge.
S&F Soap Dish brass chromium plated decorative type approximate size 160x160x90mm complete all as specified and directed by Engineer-in-Charge.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including trap set in and including concrete and connection to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of vitreous china wash hand basin, white, flat back of size 550 x 450 mm including waste coupling, CI brackets, PVC waste pipe and connection 32 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of 15mm bore pillar taps, fancy type, cast copper alloy with capstan heads, Decorative type chromium plated screwed down, high pressure screwed for iron pipe complete all as specified.
S&F PVC Mirror cabinet with shelf with PP and material of size 540mm X 340mm X 130mm fixed to wall with screw and rawl plug etc complete all as specified and directed
S&F in repairs of stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen or laboratory with plug, washers, waste pipe, cast iron cantilever brackets, connecting union of overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm.complete all as specified and directed.
S&F of stainless steel plate rack (wall mounted) as in kitchen of size 30 inch x 36 inch x 8 inch complete all as specified and as directed. (Make : A-One and equivalent as per Appendix B). Note : - Pattern of plate rack to be approved by GE.
S & F 100 mm dia spun cast iron soil waste and vent pipes sand cast in any length with or without laid in trenches or in floor with cement joints complete all as specified and directed by Engineer-in-Charge.
S & F 75 mm dia spun cast iron soil waste and vent pipes sand cast in any length with or without laid in trenches or in floor with cement joints complete all as specified and directed by Engineer-in-Charge.
S & F 100 mm dia spun cast iron soil waste and vent pipes sand cast in any length with or without ears, fixed on wall with cement joints complete all as specified and directed by Engineer-in-Charge.
S & F 75 mm dia spun cast iron soil waste and vent pipes sand cast in any length with or without ears, fixed on wall with cement joints complete all as specified and directed by Engineer-in-Charge.
S & F in repairs of 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured) complete all as specified and directed.
S & F in repairs of 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured) complete all as specified and directed.
S&F of cast iron cowls of 100 mm bore pipe complete all as specified and directed.
S & F in repairs cast iron floor trap with chromium plated graating of 100 mm size including jointing to waste pipe with cement joints etc complete as directed.
M&L for PVC (SWR) pipe of 110 mm bore single socketed in any length with rubber ring joint fixed to wall with suitable clamps of adequate numbers etc complete all as specified and directed.
S&F PVC SWR bends 110 mm bore all as specified and directed.
S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per manufacturer's specifications and as directed.
S & F for 30 mm thick factory made solid panel PVC door shutter conferming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings ass as directed by Engineer-in-Charge.
S & F for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel and fixed complete all as specified and directed.
S & F for 75mm long stainless steel butt hinges, heavy weight cold rolled and fixed complete all as specified and directed.
S & F 150 mm long aluminium anodised handles, cast type complete all as specified and directed.
S & F for 150 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 300 mm long aluminium alloy, anodised, sliding dooor bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S & F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed.
S & F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
S & F glazed/wire gauged/skeleton shutter 35 mm thick out of (well kiln seasoned) 2nd class hard wood (hollock) the size of rails and style as per IS chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, complete all as specified and directed. (Note : Wire gauge/glazing to be measured and paid separately).
S & F factory made 40 mm thick plain, framed, panelled shutter (two panel) with lock rail using 2nd class HW (Hollock) kiln seasoned andchemically pressure treated the size of rail and style as per IS 1003 (Part-I) and panel insert of 9mm thick BWP commercial facing plywood or 12mm veneered particle boards with commercial ply all complete all as specified and directed.
S & F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood complete all as specified and directed.
S&F 25 mm thick block boards, grade 2 quality interior grade, commercial type with decorative face veneers on both faces fixed with screws to timber frame work complete all as specified and directed.
S & F in repairs of 19 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work etc. in built in cupboard complete all as specified and as directed.
M & L for preparation of new wood base surfaces applying one coats of pink primer and two coats of synthetic enamel paint (ordinary tint) of any description, over 10 cm in width or girth, not otherwise described complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with SS wire staples complete all as specified and directed.
S & F mild steel 300 mm ordinary rat tail rod pattern springs including roller & roller plate complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm complete all as specified and directed.
S & F hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100 mm size complete all as specified and directed.
S & F in repairs of harrison rail mild steel chromium plated of 25 mm dia for curtain rod fixed with two Nos of brackets for each rail complete all as specified and directed.
S & F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc aluminium section weighing should not be less than 1.25 kg/m. complete all as specified and directed. (Note : Minimum thickness of powder coating 50 micron).
S & F anodised aluminium powder coated window and ventilator shutters, hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised aluminium fittings such as peg stays 150 mm long (01 No), hinges B-21 100 mm long (02 No), suitable handle (01 No) complete all as specified and directed.
S&F sheet glass 4 mm thick ordinary quality & glazing with rubber gasket in square n.exc 0.5 Sqm in each pane complete all as specified and directed.
S&F 4 mm thick figured glass, pinhead type in squares n.exc 0.50 sqm each pane complete all as specified and directed.
Preparation of new plastered surfaces of wall and M & L for applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of wall care putty 1 mm thick on plastered surface to prepare the surface even and smooth finish complete all as specified & as directed .
M &L for preparation of new plastered surfaces of wall and applying three coats of white wash on surface even and smooth complete all as specified and directed.
M & L for complete removal of existing treatment of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of wall care putty 1 mm thick over complete all as specified and directed .
M & L for preparation of old decorated plastered surfaces of wall and applying two coat of white wash on surface even and smooth complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on surface even and smooth complete all as specified and directed.
M & L for preparation of old surfaces of ceiling and applying two coats of white wash prepare the surface even and smooth complete all as specified and directed.
M & L for for preparation of new plastered surfaces and applying two coats of 100% premiumor acrylic emultion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489-2004 alkali and fungal resistance, durt resistant exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43 liter/10 Sqm over and including 1mm thick exterior putty and prepare the painted surface even and smooth finish complete all as specified and directed. Note: colour and pattern of paint will be decided and directed by GE
M & L for complete removing of existing treatment of wall surfaces by scrapping with mechanical sander (having mechanical vacuum mechanism) to make surface clean, free from dust, loose paint etc and applying two or more coats of 100% premium acrylic emultion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489-2004 alkali and fungal resistance, durt resistant exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43 liter/10 Sqm and prepare the painted surface even and smooth finish complete all as specified and directed. Note: colour and pattern of paint will be directed by GE
S&F 18/19 mm thick PVC board Rajshree Celuka ply or equivalent as approved of grade 1 quality with both side plain white or coloured fixed with stainless steel screws, solvent cement/ adhesive to fabricate kitchen cabinet sides, top and bottom, door, shelf inside the cabinet and drawer and all fittings complete all as per manufacturer’s instructions complete all as specified and directed. (NOTE :-(i) Each member i,e. top and bottom, door, shelf inside the cabinet and drawer etc. shall be measured. (ii) hinges, wire gauge and handles shall be measured and paid for separately).
S&F auto closing stainless steel (Grade 304) hinges 35 mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters of make as approved complete all as specified and directed.
S&F stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified and directed.
S&F decorated type towel ring square shape with round flange complete all as specified and directed.
Forming expansion joint of size 10 x 50 mm and filled with bituminous material as in plinth protection complete all as specified and directed.
S&F PVC bath cabinate with mirror of size 430 mm x 330 mm fixed to wall with screw and rawal plug etc complete all as specified and as directed.
Material & Labour for brick masonry valve pit internal size 600mm x 600mm x 600mm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping for grounting MS frame including 3 mm thick MS sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame be made out of 50x50x6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance upto not exceeding 50 mtrs including necessary form work with 150mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge
S & F 75 mm dia branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F 100 mm dia branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F stainless steel telescopic drawer channel heavy ball bearing 400 mm to 500 mm long all as specified and directed.
S & F in repair 15 mm bore chromium plated Wall mixer fancy type with L band provision for overhead showr, cast copper alloy with crutch or butterfly handle, fixed complete all as specified and directed.
S & F framed work such as MS grills, guard bars etc with encls of bars shoulderd and/or reverted, or forged and similar work including necessary fixing arrngement as specified and directed
Taking down carefully copper / aluminum point wiring (Light/Fan/Socket/power) complete including fittings and fixtures such as switches , ceiling roses , pendents , regulators , sockets , light fittings etc. and making good the disturbed surfaces of walls/ floors etc complete all as specified and as directed.
Taking down Light fitting complete of any type complete all as specified and directed.
Taking down DBs Complete of any type complete all as specified and directed.
Material and Labour for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 sqmm single core 1100 volts grade FRLSH PVC insulated, unsheathed multistranded copper conductor with and including PVC concealed conduit pipe 20 mm medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white plate with frame of required module at site, fixed with chromium plated screws and washers for switches and sockets, on walls, surface on roofs and beam etc including PVC insulated copper earth continuity conductor 1.5 Sqmm cable connected to common earth dolly including cutting chases in walls / floors for concealed conduit for one light, fan, bell point controlled by one switch and making good disturbed surface area by cement mortor (1:3) and to match with the existing surface / colour by using existing oil bound distemper / white wash complete all as specified and directed for the following :- Note :- Cutting chase to wall wherever required shall be included in the rate quoted for poing wiring.
One light/fan/exhaust fan point controlled by 1 No,one way 5/6 Amp switch.
One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc.
One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board.
One call bell/buzzer point controlled by one push button switch.
All as per item No.136 above wiring complete but PVC cable 2.5 Sqmm single core 1100 volts grade FRLSH PVC insulated, unsheathed multistranded copper conductor for 3 pin 15/16 Amps socket outlet on independent board complete all as specified and directed.
M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete all as specified and directed.
M&L for Modular socket outlet 2 in 1, 5 pin, 6A, flush type white finish complete all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one way, complete all as specified and directed.
M&L for Modular socket outlet 2 in 1, 6 pins, 6A and 16 A, combined 2 module white finish complete all as specified and directed.
S & F modular type ceiling rose, surface Bakelite,isolated body three terminals including taking down old one complete all as specified and directed.
S&F modular type Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete incl taking out old lamp holder complete all as specified and directed.
Material and Labour for modular bell push flush type 5/6 Amps 1 module AC circuit 240 V complete incl taking out old bell push complete all as specified and directed.
Material and Labour for modular bell (Ding-Dong) 230 volts, single pole complete incl taking out old ding dong complete all as specified and directed.
Supply and fix exhaust fan, PVC body AC single Phase. 230V of blade size 150mm sweep heavy duty minimum speed 1300 RPM with frame and louvers with all accessories for hang and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose complete all as specified and directed.
Taking down Ceiling fan, sealing cable end, dismantling blades and carry out mnr repair and fixing of damaged parts like capacitor, bushes, bearings and screws etc and keeping in safe custody of contractor up to re fixing in the same complete all as specified and directed.
M & L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Hanging only ceiling fan (M.D. Supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Supply and fixing LED tube lights fitting 1x 18W, 220V, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and complete all as specified and directed by engineer-in-charge.
Supply and fixing LED batten type tube light complete fitting 1x 10 W, 220V, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and complete all as specified and directed by engineer-in-charge.
Supply & Fixing and connecting up complete MCB DB TPN 4 way (Vertical), double door, 415 V, AC, 50 Hz, with and 16 KA , IP-40 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete all as specified and directed. Make : Havells Cat No.DHDLVDRWGOFO04 or other equivalent as per appendix 'B'.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching including taking down old one complete all as specified and directed.
S&F MCB’s single pole, 10 KA ,32 Amp to 40 Amp 240 Volts,and of ''B'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996, including taking down old one complete all as directed.
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete (for Geyser) with one single pole MCB of "C" series of cap 20 Amps including taking out the old one complete all as specified and directed.
S&F MCB’s DP, 10 KA, 32 Amp to 40 Amp 240 Volts,and of ''B'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board. MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996,including taking down old one complete all as specified and directed.
Supply and fixing STUD 10 W LED lights energy saving Bulk Head Luminaries including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and complete all as specified and directed by engineer-in-charge.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unsheathed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as neutral cable ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm earth continuity conductor all as specified and directed including taking down old sub main wiring complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth continuity conductor and conduit shall be measured as one RM unit.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unsheathed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4.0 sqmm as neutral cable ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm earth continuity conductor all as specified and directed including taking down old sub main wiring complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth continuity conductor and conduit shall be measured as one run metre unit.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm stone agrigrtae ) reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1 including testing and taking out the old one existing earthing complete all as specified and directed. Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate NRV, connection piece etc including submit the old water heater to MES store complete all as specified and directed.
S & F 415 V, 10 KA , ''C'' curve MCCB TPN 63 Amps, 16 KA complete all as specified and directed by Engr in Charge.
Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93, IP 65 comprising of the following :-
a) TPN aluminium bus bar 630 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long b) Incoming: MCCB 400 Amps 4 pole 415 Volts AC,Icu=100%Ics, having microprocessor based release for over current, short circuit & earth fault with display and fault discrimination rupturing capacity 25 KA Confirming to IS/IEC 60947-2 -01 Nos (c) MCCB TPN 63 Amps 16 KA - 08 Nos (d) Indicator lamps LED type RYB with holder -01 Set of three (e) CT Coils of suitable ratio -01 Set.
Note (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLSH cable as per- IS 694 (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE.
Supply, Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty size 120 sqmm 3.5 core 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc including complete all as directed including taking out old damaged cable and all as specified and directed. Note : excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately.
Supply, Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty size 35 sqmm 4 core 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc including taking down old UNSV cable of any size complete all as directed including taking out old damaged cable and all as specified and directed. Note : excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately.
M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified and directed.
Supply & laying sand cushioning for cable protection in trenches 8 cm thick before laying cable and 15 cm thick over the cable as loose sand thickness complete all as specified and ditected. Note: Sand cushioning thickness (8 cm+15 cm=23 cm) are punned thickness and only Punned thickness will be measured and paid.
M&L GI tubing 50 mm dia light grade ISI Marked, laid in trench/floor or fixed on wall with all fixing accessories etc complete incl taking out old damaged GI pipe all as specified and directed.
S & F of Sheet metal enclosure factory made powder coated size 60x60x18cm made out of 2 mm thick MS sheet with double door, suitable locking arrangements suitable for fixing DB and Electric meter, cutting chasing in wall and fixing and making good as per existing surface complete including taking out and removing old one complete all as specified and directed by Engineer-in-Charge
M/S Rohit Enterprises (BID ID -3129479)
PAPPU ROY CONSTRUCTION (BID ID -3137345)
RC GUPTA AND SONS (BID ID -3136908)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .