Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1 L
Closing Date
22 Nov 2021, 4:30 pmClosed
xen rew kathua
xen rew kathua
Repair/Renovation of toilet complex at GMS Sanyal
2021_RDPR_147541_6
e-NIT No. 166 /REW/K of 2021 Dated 11/11/2021
Open Tender
Civil Works
Item Rate
30 days
hiranagar
sbd
2 documents required · 2 mandatory
₹500
Yes
xen rew kathua
Exempted
23 Nov 2021
11 Nov 2021
23 Nov 2021
12 Nov 2021
22 Nov 2021
12 Nov 2021
Amount
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer- in?charge:15.2.1 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
a. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
b/ Cement concrete pavement with 1:2:4 (1cement: 2 coarse sand: 4 graded crushed stone aggregate 20 mm nominal size) including finishing and curing complete
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. qty. vide item 9 = 3.15 @70kg per cum
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4( 1 cement : 4 coarse sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching igments etc. complete, Size of tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. one or more coat old work
Centering and shuttering including strutting, propping etc. and removal of form work for:4.6.1 Foundations, footings, bases for columns
Providing and fixing water supply, plumbing and sanitary fittings:- a/ G.I. Pipe i= 15mm bore
b/ P/F C.P.brass short body bib cock 15mm nominal bore
c/ P/F C.P Brass Angle valve 15mm n bore
d/ P/F stop cock 20mm n bore
e/ P/F Floor Trap 75mm
f/ P/F C.I. grating 110mm
g/ P/F Towel rail 450mm
h/ P/F Soap dish
i/ P/F PVC bends a)=110mm
" " " tee a)=110mm
" " " Tee b)=75mm
" " " Pipe a)=110mm
j/ P/F PVC waste pipe 32mm
k/ P/F PVC connection 45mm
l/ Tank nipple 20mm
l/ P/F Mirror
m/ P/F Water closet squanting pan ( Indian Type W.C.) incl. P or S trap,10 litre low level flush cistern complete.
Renewing glass panes, with wooden fillets wherever necessary : 14.7.1 Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base supportfor tank
Providing and fitting electric points.all complete
Labour for necessary repairs to door/windows Carpenter
Semerjeet Singh
M/S PARDEEP JAMWAL GOVT CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .