Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹31.9 L+₹94,016.41 (3.04%)Rejected-AOC NEAR GURUDWARA JHANSI BHOPAL ROAD SAUGOR M P 470002 | SAUGOR | SAGAR | MADHYA PRADESH | 470002 | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹63,460
Closing Date
8 Dec 2020, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPL REPAIR TO BLDG NO PG-12 (MD ACCN OF FOUR JCOs) AND SPL REPAIR TO ROOF TREATMENT OF OR MD ACCN BLOCK NO PH-08, PH-11 AND PH-13 OF 321 FD REGT AT DHANA MIL STATION
2020_MES_394333_1
83595/E8
Open Tender
Civil Works
Item Rate
180 days
DHANA
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
AGE (I) DHANA
₹63,460
Yes
5 Jan 2021
11 Nov 2020
10 Dec 2020
11 Nov 2020
8 Dec 2020
25 Nov 2020
Amount
Demolition of cement concrete (un-reinforced ) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified.
M&L for repairing of damaged RCC chajja's/ Roof projection ,ceiling and balcony railing etc at any location up to 10 Mtr height ,comprising of following operation complete all as specified and directed . (a) Dismantling of all loose cement mortar/concrete , cleaning of rust on exposed reinforcement using 'rust cleaning solvents' Dr. fixit rust clear or equivalent. (b) M&L for application of anti-corrosive/passive coat of '' RBR ''of Pidilite or equivalent cement sluury in cm (1:2) @ 3.0 Kg/Sqm . (c) M&L for application of a bonding coat of '' RBR ''of Pidilite or equivalent cement sluury in cm(1:2) just before repair . (d) S&F of chicken wire mesh as directed . (e) M&L for repair to damaged portion using cement mortar(1:3) of 20mm to 40 mm thick in one or two layers as required , admixing '' RBR '' or equivalent @ 2.0 liter per bag of cement .
Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed.
Material & labour for rendering 15 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction all as specified. Note;- Water proofing compound shall be measured and paid separately.
M & L for ponding test by filling 75 mm deep water over roof treatment by making necessary arrangement to fill the complete Roof slab at least for 72 hrs complete all as specified and directed.
M & L for Injecting grout of epoxy mixed with ordinary Portland cement 43 grade in proportion as per instruction of the manufacturer into RCC roof by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete all as specified and as directed.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP membrane HMHDPE 3 Kg plain (thickness 2.1 mm) (total weight of the finished membrane not less than 3.0 kg/ sqm ± 5 % per sqm) confirming to IS 16540: 2017 over a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25⁰C, 0.87-0.89 kg/ litre and viscosity 70-160 cps, laying over the primer coat using Butane Torch and sealing all joints, overlapping etc. as per Annex D of IS 16540: 2017 complete all as specified and as directed.
M & L for cutting grooves or chase in brick wall, 75 mm wide and 65 mm deep and including filling with cement mortar 1:4 mixed with water proofing as mentioned in Annex D of IS 16532: 2017, IS 16540: 2017 compound complete all as specified and as directed.
M & L for PCC benching/ angle filleting at the junction of parapet and RCC roof in M15 (Nominal Mix) using 12.5 mm nominal size crushed stone aggregate mixed with water proofing compound as mentioned in Annex D of IS 16532: 2017, IS 16540: 2017 compound complete all as specified and as directed.
M & L for plain cement concrete tiles, general purpose, double layer of size 25 cm X 25 cm X 22 mm thick with grey cement and no pigments in wearing layer as per IS 1237: 2012, including laying over 15mm thick bedding of cement mortar (1:3) and neat cement slurry, set, jointed and grouted i cement mortar (1:3) mixed with 2% integral water proofing compound by weight of cement in 4 mm wide joints all as specified and as directed Note:- Water proofing compound shall be measured and paid for separately.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course mass concrete finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately.
M&L for sunken floor treatment follows as per (S. No. 13.01 to 13.06) :-
Demolition of cement concrete in Sunken floors complete all as specified and directed.
M&L for PCC(1:1 1/2:3) type A-O using 12.50 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion wint proper slope towards spout. Note: Water proofing compound shall be measured and paid separately.
M & L for plastering on vertical sides in CM (1:3) 15mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green ie . PCC & Plaster be carried out at the same time. Note: Water proofing compound shall be measured and paid separately.
M & L for two coat of Dr fixit epoxy compond shall be applied after laying sewage / pluming pipes with fixtures in position.
M&L to filling the sunken floor with PCC ( 1:5:10) type E-2 using brick aggregate over the treated surface.
Spouts of 50mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. Note: water tightness testing should be done after apply Dr fixit epoxy compound by pounding water for 72 hours & rectify defects if any till tatal elimination of defect.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises.
M & L for 25 mm thick PCC 1:2:4, typeB-O, using 12.5mm graded stone aggregate finished fair and even etc complete all as specified
M&L for Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L for Glazed ceramic colour tiles of size 300 x 450 x7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M & L for machine cut kota stone slab (one piece steps) flooring 20-25mm thick over 15mm thick cement screed bed in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for kota stone slab 20-25mm thick in riser of steps (one piece type) , skirting, dado and pillar laid over 10 mm thick backing coat of cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Granite (of any type) tiles 20mm thick machine cut, in , bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing complete all as specifed and directed by EIC.
Taking down wooden chowkhat or frame area exc 1.5 sqm and not exc 4 Sqm each with shutter (without taking off shutter from frame) as directed.
Ditto all as per item No 22 above but not exc 1.5 Sqm each
Taking down wooden shutter of any descripton exc 1 Sqm and not exc 2 Sqm each as directed.
S&F 165 x 60 mm size Pressed steel frames 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed.
M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified
S & F 35 mm thick factory made Second class hard wood Glazed and skeleton door shutters, open rebated divided into squres (three panels) and prepared to receive gauze with sash bars, edges of framing plain fitted with cut and mitred beads (all around of Ist class soft wood) for securing wire mesh or glass, size of members of shutter as specified in SSR Pt-I Sec-8 clause 8.24(a) fitted to chowkats, complete as specified and directed.
Supply and fixing 35 mm thick 2nd class HW plain, framed, factory made panelled shutters (two panels), with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), cleaned seasoned and chemically pressure treated.
Providing and fixing ECO-4000 series pre-coated double rebated openable window or ventilator made out of galvanised steel colour coated/powder coated (base steel as per IS 513 of 'D' quality galvanised as per IS 277 with zinc of 120 gm/Sqm) with total thickness of coating 0.58 microns finished painted with polyster paint of 12 to 16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with polyster powder up to 50-60 microns thick outer frame section 72x55 mm, centre mullion section 72x50 mm, shutter section 47x20 mm, fly mesh section 40x20 mm and the fixed glass beading section 12x12 mm outer frame and mullions shall consist rebate for glazed shutter, fly mesh and 20 mm provision for gaurd bars/grills, the section cut to length miter jointed with corner brackets, center mullions fixed with mullion cap, stay handles, latch 2 Nos of heavy duty stainless steel pivot hinges per shutter and paneled with 5 mm thick pain float glass and stainless steel (304 grade) mesh for fly mesh shutter fitted with EPDM (Ethyl Propylene Diamine Monomer ) gaskets including fixing window with concrete/stone or brick masonary wall by means of self expanding sleeves and driving MS electroplated 80 mm long bolt into the sleeves through frames (Minimum 4 nos for 1600mm high windows, 3 Nos for 1200 mm less window and 2 nos in ventilator ), including 10 mm square bars welded to 6x12 mm flat at a distance 125 mm c/c etc as per direction of engineer in chaege. Note Refer TD No CELZ/C-TD/102 sheet 1/2 and 2/2.
Supply & fixing for plain sheet glass 4mm thick, glazing in aluminium frames and ms pre coated frames, area not exc. 0.50 sqm in each pane, complete all as specified and directed.
Supply & fixing for frosted glass / tined glass 4mm thick glazing in aluminium frames and ms pre coated frames, area not exc. 0.50 sqm in each pane, complete all as specified and directed.
S&F framed work such as grills, gratings, etc. with end of bar shouldered and/or riveted or forged in to spikes framed gaured bars barred iron doors, ladders, framed blausters, walk ways, railings, frame work of water tanks and similar work confirming to Fe 290 Gde-E-165
S&F solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in door opening as per specification and drawings.
S&F factory made solid panel PVC door shutter 30mm thick (style ) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuch in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frame at site as per specification & drawing.
Supply and fixing 150mm size Extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed.
Supply and fixing 150 mm size aluminium anodised,barrel tower bolts of extruded section and fixed with ISI marked complete all as specified and directed.
M&L for 2nd class hard wood plain fillets, square, rectangular in section wrought screwed with nails area exceeding 13sqcm but not exceeding 25 sqcm
M & L for 18/19 mm thick prelaminated particle board, interior grade, pre-laminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws as in in cup board shutters, partitions, shelves including S & F 6mm thick teak wood beading all arround in edges of prelaminated board etc, complete as specified and directed.
S & F in repair Block boards 25mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work etc, including S & F 6mm thick teak wood beading all arround edges of block board complete as specified and directed.
Supply and fixing 100 mm butt hinges medium weight cold rolled mild steel ISI marked fixed by welding to the pressed steel door frame as in repairs, complete as specified and directed.
S&F 100 mm hasp and staple, mild steel, safety type, stove enamelled black, including bolt to hinge plate and fixed with wooden screws,but of aluminium anodised complete all as specified and directed.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flap 30 mm complete all as spd
S&F aluminium alloy anodised sliding door bolt with hasp staple (bolt type) length 300mm complete all as specified and as directed.
S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples, complete all as specified and directed.
Ditto all as per item no 44.00 above but fixed in repairs
M&L for cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for fixing hold fast, coping, cills and filling in pressed steel door frames including necessary form work and finishing the surfaces to match with existing, complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cm (1:4) complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete the surface even and smooth without using extra cement in CM (1:4) Mixed with water proofing compound @ 3% complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work/concrete surfaces, finished even & smooth (without using extra cement), complete all as specified and directed.
M&L for 5mm rendering thick in CM (1:3) on concrete sufaces, finished even & smooth (without using extra cement), complete all as specified and directed.
M&L for applying a coat of Birla wall care putty as per manufacture instruction complete all as spd. Note: Thickness of putty shall be as per manufacturer instructions.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and directed.
M& L for complete removal of existing treatment by scrapping, wire brushing from old walls and applying two coats of oil bound distemper including preparation of surfaces as directed.
M & L for complete removal of existing treatment and appllying two coats of weather proof exterior paint over a coat of primer and putty where required on wall including preparation of surfaces complete all as specified and directed. Note: Thickness of putty shall be as per manufacturer instructions.
M&L for Preparation of new plastered surfaces of wall and applying two coats of Exterior emulsion paint over a coat of primer all as specified and directed
M&L for preparation of old decorated plastered surfaces of ceiling including cornices, pilasters etc and applying two coat of white wash complete all as specified and directed.
M&L for White wash, three coats on new ceiling surfaces including necessary preparation of surfaces complete all as specified and as directed.
M&L preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer, complete all as specified and directed.
M&L preparation of old steel surfaces and applying 2 coats of synthetic enamel paint of any description over 10 cm width and girth complete all as specified and directed.
M&L for preparation of old wooden surface and applying two coats of synthetic enamel paint exceeding 10 cm width or girth etc complete all as specified and directed.
S&F for vitreous china wash basin white flat back size 550x400mm including pedestal excluding taps , waste but including brackets as in repair, complete all as specified and directed.
Supply & fix 15mm bore pillar tap fancy type, cast copper alloy with capstan head, chromium plated screwed down, high pressure with or without lettered “hot “ or “cold” with long screwed shanks and fly nut complete all as specified and directed.
S & F 32 mm dia, Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
S & F for PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specfied and directed.
S & F brass chromium plated tubular towel rail, 20 mm dia., D Type, 45 cm long between flanges, complete all as specified and directed.
S & F stainless steel sink with drainage board, made out of 1.00 mm thick sheet for kitchen or laboratory with plug, washer & waste pipe (PVC flexible pipe of 32/40 mm dia) fixed on cantilever angle iron bracket, connecting union overall size 915 x 460mm with bowl size 410 x 330 x 160 mm, complete all as specified and directed.
S & F Chromium plated shower rose 125 mm size with swivel joints including fixing to steel pipe or union as in repair, complete all as specified and directed.
S & F soap dish vitreous china white approximate size 160 x 160 x 90 fixed to plug with chromium plated brass screw complete all as specfied and directed.
S&F mild steel chromium plated grating of 125 mm dia fixed in repair.
S&F in repairs vitreous China squatting pan, 'Orissa' pattern, size 580xmmx440mm white, with integral foot rests (excluding flushing cistern, flush pipe and waste pipe) and ‘P’ or ‘S’ trap front or back inlet including concrete bedding, complete all as specified and direrected.
S&F in repair 10 ltr capacity PVC valveless,syphonic action type, flushing cistern, low level, white, with inlet ball valve , float and handle including brackets, complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store
Supply & fixing steel water tubing medium grade galvanizes fixed to walls, floors roof ceiling etc including all tube fittings of 15mm bore complete all as specified and directed.
Supply and fix in repairs 15mm stop valve fancy type chromium plated concealed
Supply and fix in repairs bib tap 15mm fancy type chromium plated
Dismantling unserviceable PVC water storage tank of 500 Ltr capacity, all as directed.
S&F 500ltr capacity rotational mounded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning using bleaching powder, repairing, etc. complete all as specified and directed.
S&F 20mm bore ball brass valve, high pressure with polyethylene float and fly nut complete screwed for iron pipe or brass ferule complete all as specified and directed.
Ditto all as per item no 84.00 above above but fixed in repairs Make:- Prayag/ polytuff/ Shakti
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads shoes,bends,swan-necks, etc, including, cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
S&F PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls for 110mm bore
S&F PVC Bends any radius 110mm bore
S&F PVC (SWR) couplers nomminal bore in mm joints fixed to walls for 110mm bore complete all as specified and directed.
S & F 25mm dia draphery rod (Poles, finials , ring & bracket complete all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C-2 using 40mm graded stone agg finished even & smooth without using extra cement as in plinth protection including forming joint to full depth at every 3.0m interval and at every charge of direction and filled mixture of bitumen and sand (1:3) by weight, complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/ dense soil, complete all as specified and directed.
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75 mm thick PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate finished fair and even etc complete all as specified
M&L for Durastone / Endura tiles of size 322mm x 322mm x 9.5 mm thick as in floors set and jointed in neat cement slurry and pointed in white cement to match the surface complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified.
Removing demolished material to a distance exc. 1.50 km but n. exc. 5 km and depositing where directed.
Complete removal of existing treatment of wall and M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
Complete removal of existing treatment of wall and M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed Note: Thickness of putty shall be as per manufacturers instruction.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
Supply and fixing in 20 mm dia float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.
Fixing in repair 20 mm dia float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.
S & F in repairs 15 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
Taking down carefully copper/aluminium point wiring for light, fan, bell, socket, power socket etc complete with boards outlet boxes fitting and fixtures such as switches, sockets, lamp holders, bracket, ceiling rose etc and removing from site and making goods the disturbed surfaces to match with existing complete all as specified and directed.
Disconnecting electric connections and taking down old unserviceable main switches/ DB’s steel metal enclorsers 02 ways, 4 ways, 8 ways/ duly fitted with MCB’s/ cutouts 32 amps capacity including unserviceable wooden boards and making good the disturbed surface of the wall/ceiling complete all as specified and directed.
Disconnecting & taking down of unserviceable sub main / Service connection of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces complete all as specified and directed.
M & L for Submain wiring with two run of single core 6 Sqmm multi stranded ISI marked PVC insulated copper conductor cable drawn through concealed in surface in PVC rigid conduits and the conduits accessories not less than 25 mm incl one run of earth continuity conductor with 6 sqmm multi stranded copper conductor cable all as specified and directed. Note :- Two run of single core cable, one run of earth continuity conductor and one metre of conduit shall be measured as one unit.
M & L for point wiring complete with 1.5 sqmm single core multi stranded copper conductor ISI marked PVC insulated unsheathed (FR-LSH) cable 1100 volts grade drawn through and including PVC non metalic rigid conduit & conduit accessories not less than 20mm dia concealed in Wall/ roof/ceiling with PVC sleeve/ dash fasteners/ wooden gutties and cadmium plated screws as per IS including sunk type MS anodised terminal boxes with 3 mm thick PVC laminated sheet concealed in wall etc including 1.5 sqmm unsheathed copper continuity conductor connected to common earth dolly for :-
One light/fan/bell point controlled by one, one way,SP, 5 Amps switch
One socket outlet 5 pin, 5 Amps on the same board
One socket outlet 5 pin, 5 Amps on the independent board
One light point controlled by one, two way, SP , 5 Amp switch, completa all as specified and directed.
One 5 pin 15 amps socket controlled by Indp. 15 Amps switch but with cable 2.5 sq.mm..
S & F switch piano,flush button,15 Amps, single pole one way complete all as specified and directed.
M&L for socket outlet 15 amps, 6 Pin, flush type complete all as specified and directed
S & F switch piano type, flush button single pole, one way 5 amps complete all as specified and directed.
M&L for socket outlet 5 amps, 5 Pin, flush type complete all as specified and directed.
S & F switch piano type, flush button two pole, two way 5 amps complete all as specified and directed.
S & F ceiling rose, surface bakelite 65x 17.5 mm, three terminal complete all as specified and directed.
S & F ceiling fan regulator stepped type,230 volts suitable for 1200mm/1400mm sweep complete all as specified and directed.
S&F Batten lamp holder, PVC/polycarbonate type wirth back plate suitable for batten lamp holder.
S&F New Adore LED lamps 10W B22 COL BALL LAMP , Make: Cat part no- LHLDERUEMD8X010 of HAVELLS or equivalent as approved by the GE.
S&F Electric call Bell, AC 230 volts,SP complete all as specified and directed.
S&F Bell push, flush type, 5Amp complete all as specified and directed.
S&F MCB distribution board steel sheet, enclosures power coatad fitted with bus bar, neutral link, earth bar din rail conforms IS-8822:96 and EIC 898-96,240 volts double door complete all as specified and directed:-
04 way,415 Volts, TPN
08 way,240 Amp,SPN
S&F MCB in DB's/ Isolator of the following rating complete all as specified and directed :-
Isolator four pole, 63 Amps 415 V
MCB SPN 40 Amps, curve 'C' breaking capacity10 kA.
MCB SP 6- 32 Amps, curve 'C' breaking capacity10 kA.
S&F LED tube light fitting (seprate box fittng and LED rod) arcylic linear tube (1x 18 watt), 230V for single LED light fitting & rod (1 x 18W LED) bar professional CW 6500 K cover channel in box fitting, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make: Bajaj Code No BLRB-DB 118 & BLRB 18W CW or equivalent make of Havells/ Philips and crompton greaves.
Supply and fixing, testing and commissioning energy saving security light luminaire 15 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate cover, complete with individual LED lences including suitable size of street light bracket with clamp and fixing on wall complete all as specified and directed. Make:- Bajaj Cat part :-BCLST 15W LED or equivalent make of Philips/ crompton greaves
M & L for earthling complete with GI earth plate electrode 60 cm x 60 cm x 6.30 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 5 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work, PCC pit with RCC cover, charcoal salt funnel, GI wire up to 7.5 mtrs length complete all as specified and directed.
Taking down old unserviceable ceiling/exhaust fans and deposite to MES Yard carefully complete all as specified and directed.
Supply and fixing fans ceiling single pole 230/240 volts of size 1200 mm sweep,BEE 5 star rated, including blades, capacitor and necessary connection by three core flexible cable etc complete all as specified and directed.
Supply & Fix single phase heavy duty Exhaust Fan of 300 mm Sweep with louver Cutting of existing wall for making hole for fixing of 300 mm sweep exhaust fan including PCC / brick work complete all as specified and directed by Engr - in - Charge
S&F LED mirror light fitting, 1x 5W, attractive wall/ceiling mounted type with metallic channel and white reflector, suitable for mirror fittings with complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size for connection from ceiling rose to mirror light fitting complete all as specified and directed. Make: Bajaj Code No: BCLSB 05 WH or equivalent make of Havells/ Philips and crompton greaves.
Supply, Laying, testing of cable XLPE/ PVC Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sq mm 4 core
Excavation in trenches in hard/dence soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC/Steel tubular poles/stays and struts etc getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site
M & L for old size sub class 'B' bricks straight or curved on plan exc. 6 mtr mean radius for cable cover.
M&L for sand cushioning to PVC/ XLPE cables with river sand and punning to provide required cover to UG cables, complete all as specified and directed. Note :- For the purpose of payment only punned thickness will be measured.
Supply and fix light grade 50mm GI pipe fix complete to Wall , Poles etc with suitable clamp for protection of cable complete all as directed
Disconnecting and taking down energy meter and keeping aside safety & reconnecting & refixing the same after repair work complete all as specified and directed.
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
SAGAR MOTOR AND TRACTOR CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .