Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC L1 bidder with awarded value Rs 5,96,000/- inclusive GST and all other taxes | |
| 2 | L2₹8.1 L+₹2.1 L (35.7%)Rejected-Finance K L MARKET NEAR VISHNU CINEMA BEGUSARAI BIHAR BEGUSARAI BIHAR BEGUSARAI BIHAR 851101 | BEGUSARAI | BIHAR | 851101 | L2 | Rejected-Finance L2 Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Bidder does not meet PQC as per NIT | |
| 4 | Rejected-Technical | - | Rejected-Technical Bidder does not meet PQC as per NIT |
Tender Value
₹5.7 L
EMD Value
₹5,677
Closing Date
30 Jan 2023, 5:00 pmClosed
DEPUTY GENERAL MANAGER (CGD)
INDIAN OIL CORPORATION LIMITED (PIPELINES DIVISION) EASTERN REGION PIPELINES, HIRA NIKETAN, KALIKET NAGAR, BAILEY ROAD, PATNA 801503 (BIHAR)
Supply and installation of 1 no fully automatic RO potable water purification system 500 LPH capacity with auto cut off facility along with installation of 01 Borewell and associated composite works at Nutrition Rehabilitation Center (NRC), Sadar
2023_ERKLK_161624_1
ERPL/PCO/TS/2022-23/031
Open Tender
Civil Works
Works
60 days
Aurangabad, Bihar
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,677
Yes
11 Feb 2023
13 Jan 2023
31 Jan 2023
13 Jan 2023
30 Jan 2023
13 Jan 2023
Amount
Fully automatic RO potable water purification system
Supply and installation of fully automatic RO potable water purification system 500 LPH capacity with auto cut off facility as per technical specification mentioned in tender document. Rate must be inclusive of packing, forwarding, freight, inspection, transit insurance etc. and any other associated cost in order to deliver item as per the technical specification and requirement mentioned in tender document.
Borewell along with associated works
Supply and installation of Submersible pump set single phase with motor rating 1.1KW at Sadar Hospital Aurangabad in Aurangabad district of Bihar. Rate must be inclusive of packing, forwarding, freight, inspection, transit insurance etc. and any other associated cost in order to deliver item as per the technical specification and requirement mentioned in tender document.
Supply and installation of 1.5 sqmm 3 core Flat cable for submersible pump Sadar Hospital Aurangabad in Aurangabad district of Bihar. Rate must be inclusive of packing, forwarding, freight, inspection, transit insurance etc. and any other associated cost in order to deliver item as per the technical specification and requirement mentioned in tender document.
LT Cables FRLSH - Copper cables - 1.1 KV. Rate must be inclusive of packing, forwarding, freight, inspection, transit insurance etc. and any other associated cost in order to deliver item as per the technical specification and requirement mentioned in tender document.
Supply and installation of 1000 Litre Food Grade Water Storage Tank at Sadar Hospital Aurangabad in Aurangabad district of Bihar as per technical specification mentioned in tender document. Rate must be inclusive of packing, forwarding, freight, inspection, transit insurance etc. and any other associated cost in order to deliver item as per the technical specification and requirement mentioned in tender document.
Supply and installation of 1000 Litre SS Water Storage Tank at Sadar Hospital Aurangabad in Aurangabad district of Bihar as per technical specification mentioned in tender document. Rate must be inclusive of packing, forwarding, freight, inspection, transit insurance etc. and any other associated cost in order to deliver item as per the technical specification and requirement mentioned in tender document.
Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (Part-I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment, tools, plants & machineries required for the job, all complete as per directions of the Engineer-in-Charge, up to 90 metre depth below ground level In all types of soil (a) 300 MM DIA
Supplying, assembling, lowering and fixing in vertical position in bore well Un-plasticized P.V.C. medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per directions of the Engineer-in-Charge (a) 100 mm nominal size diameter
Supplying, assembling, lowering and fixing in vertical position in bore well, Un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per directions of the Engineer-in-Charge (a) 100 mm nominal size diameter
Internal Work - Exposed on wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per directions of the Engineer-in-Charge (a) 20mm nominal outer dia pipes
uPVC COLUMN PIPES FOR SUBMERSIBLE PUMPS: Supply and installation of UPVC column pipe (Standard- 25 Kg/cm2) into the Borewell including all fittings as per direction of Engineer-in-Charge (a) 32 mm nominal outer dia pipes
Providing and laying Polished Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of concrete work)
Designing, providing, fabricating and fixing profiled sheeting 730-1020 mm cover width, 28-30 mm crests @ 186-333 mm centre to centre, manufactured out of 0.45 mm BMT (Base Metal Thickness) Hi-Tensile Steel (Minimum yield strength of 550 MPa) coated with hot dip metalic galvalume/ zincalume coating AZ-150 or equivalent as per AS:1397 and super polyster XRW quality paint coat as per AS/ NZS2728 (Category-3) of approved colour for roofing, cladding, gutters, rainwater pipes, spouts etc. The total mass of the coating on both sides shall be 150 gms/sqm (Zinc 45%/ Aluminium 55%). The total paint coat thickness shall be 35 microns, comprising of 20 microns exterior coat of super polyster XRW on top surface and 5 micron super polyester on back surface over 5 micron primer coats on both surfaces including side and end laps. The sheets shall have wide pans with 2-3 stiffening ribs for effective water shedding and special male/ female ends with full return legs on side laps for purlins support and anti-capilary flute in side lap. The sheets shall be fixed using polymer coated hot dip galvanised hex head self drilling fasteners as per AS:3566 (Class-3) on each crest of sheets for connection with purlins and polymer coated hot dipped stitching fasteners at 300 mm c/c on all sides and end laps, etc. Approved sealing tapes shall be used on side laps and end laps of sheets and closer to be provided at the last end of sheet. The measurement shall be based on per unit of finished/ laid area. Item to include curved sheets also wherever required. The Contractor shall give minimum 10 year guarantee for the sheets against deterioration, disintegration, loss of lustre, variation in colour, etc. and leakages across laps, fasteners etc. The Contractor is to submit design and shop drawing for approval on the sheet profile, design and details before installation
Roof, side cladding, gable end cladding, gutters, rainwater pipes/ spouts etc. [Note: The area of sheet coverings shall be measured on the flat surface i.e. without allowance for laps and ribs]
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level (a) 1:1.5:3 [1 cement : 1.5 coarse sane (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources]
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level (a) Thermo-Mechanically treated bars of grade Fe-500D or more
DURGA REFRIGERATION WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .