| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC | ₹1.2 Cr | 1 | Accepted-AOC L1 Vendor - Accepted. |
| 2 | 2₹1.3 Cr+₹8.9 L (7.28%)Rejected-AOC | ₹1.3 Cr+₹8.9 L (7.28%) | 2 | Rejected-AOC L2 Vendor |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
29 Nov 2023, 12:00 pmClosed
MANAGER PURCHASE
C-DOT, ELECTRONIC CITY PHASE-1, HOSUR ROAD, BENGALURU
UNDERTAKING OF CIVIL WORKS AND ALLIED ACTIVITIES FOR DRAX CENTRE AND GL CABIN
2023_CDOT_779947_1
C-DOTB/TENDER/2023-2024/006
Open Tender
Civil Works
Turn-key
120 days
ELECTRONIC CITY- PHASE-1, HOSUR ROAD, BENGALURU -
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2.3 L
Yes
CAMPUS, ELECTRONIC CITY- PHASE-1, HOSUR ROAD, BLR
22 May 2024
8 Nov 2023
30 Nov 2023
8 Nov 2023
29 Nov 2023
16 Nov 2023
8 Nov 2023 - 15 Nov 2023
16 Nov 2023
Amount
UNDERTAKING OF CIVIL WORKS INCLUDING AL. DOORS / PARTITIONING, FALSE CEILING,PAINTING, SUPPLY & INSTALLATION OF AIR CONDITIONERS,FOR EXTENDED DATA CENTRE AND GL CABIN LAYING OF NEW SEWAGE LINE & OTHER ALLIED ACTIVITIES ON TURN-KEY BASIS
RAISED FLOORING WORKS: PANEL DIMENSIONS 600 X 600 MM PANEL THICKNESS (WITHOUT COVERING) FROM 28MM. THE AIR CONDITIONING PANEL IS COMPATIBLE WITH ALL MERO FLOOR SYSTEMS. SYSTEM WEIGHT : 47 - 64 kg/m2. PANEL WEIGHT : 14 - 21 kg/pc. PANEL MATERIAL: STEEL CONSTRUCTION, CONDUCTIVE POWDER COATING, SCREWED ON REQUEST UNDERSTRUCTURE. GRID: 600 X 600 MM PEDESTAL MATERIAL GALVANIZED STEEL CONSTRUCTION. EXISTING DATE CENTRE RAISED FLOOR MATCH WITH SAME..
EARTH WORK FOR PIPE FIXING: MARKING OF LEVELS AND EXCAVATING TRENCHES OF REQUIRED WIDTH FOR PIPES, INCLUDING EXCAVATION FROM NATURAL GROUND LEVEL AND DRESSING OF SIDES, RAMMING OF BOTTOMS, UPTO DESIRED DEPTH FOR MAINTAINING THE SLOPE FOR WATER FLOW FROM STARTING POINT TO STP PLANT INCLUDING GETTING OUT THE EXCAVATED SOIL AND THEN RETURNING THE SOIL AS REQUIRED, IN LAYERS NOT EXCEEDING 20 CM IN DEPTH, INCLUIDNG CONSOLIDATING EACH DEPOSITED LAYER BY RAMMING WATERING ETC., AND DISPOSING OF SURPLUS EXCAVATED SOIL AS DIRECTED WITHIN A LEAD OF 50 M. PLEASE REFER TO DRAWING ENCLOSED AT PAGE 8 OF TENDER DOCUMENT.
SUPPLY & FIXING OF PVC PIPE: PROVIDING AND LAYING OF 8" DIA PIPE WORKING PRESSURE 6 KG / CM2. ANY ISI APPROVED BRAND:
PCC FOR PIPE SUPPORT: PCC SHOULD BE LAID IN EXCAVATED AREA BEFORE PLACING THE PIPE FOR ENTIRE LENGTH. THE THICKNESS OF PCC SHOULD BE MAINTAINED AS 4" AND MINIMUM 1 FEET WIDTH.
ALUMINIUM PARTITION REMOVE & REFIXING LABOUR WORKS: EXISTING ALUMINIUM PARTITION REMOVE AND RE-FIXING LABOUR CHARGES. EXISTING ALUMINIUM PARTITION TO BE REMOVED AT ONE PLACE AND FIX THE SAME AT ANOTHER PLACE WITHOUT ANY DAMAGE AND NECESSARY HARDWARE TO FIX THE SAME.
VERTICAL BLINDS FOR WINDOWS: SUPPLY AND FIXING OF VERTICAL BLINDS (BRANDED) FOR WINDOWS - SHADE # 402: MAKE: ANY ISI APPROVED. SHADE COLOUR TO BE APPROVED BY C-DOT
AIR CONDITIONERS: SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 2 TON 5 STAR INVERTER TYPE ACS WITH STABILIZER, OUTDOOR UNIT STAND AND NECESSARY POWER CABLE CABLE. COMPLETE TURN-KEY JOB. WARRANTY - 3 YEARS ON-SITE WARRANTY. SUGGESTED MAKES: LLOYD, VOLTAS, LG, SAMSUNG FOR DETAILED SPECIFICATIONS OF AC PLEASE REFER TO SL. NO. 7 - SPECIFICATIONS - PAGE 7 OF TENDER DOCUMENT.
UPVC SLIDING WINDOWS: REMOVING THE EXISTING M S WINDOWS AND NECESSARY CIVIL WORK AND SUPPLY AND FIXING OF UPVC 3 TRACK SLIDING WINDOWS AND OUTER ONE MS SAFETY GRILL IWTH FRAME USING 10 MM RODS. SAMPLE AVAILABLE WITH C-DOT (i.e) 2 TRACK WITH CLEAR GLASS AND 1 TRACK WITH MESH) MAKE: ANY ISI APPROVED SAMPLE GLASS THICKNESS: 5 MM(IS 2553:1990)
60 KVA MODULAR UPS: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 60 KVA MODULAR ONLINE UPS WITH 30 MINUTES BACKUP BATTERY BANK ON FULL LOAD CONDITION WITH NECESSARY STAND AND NECESSARY DC SWITCH (MCCB). BATTERY INTERCONNECTING CABLE AND UPS INPUT COMPLETE TURN-KEY JOB. FOR DETAILED SPECIFICATIONS PLEASE REFER TO PAGE NOS. 9 -14 OF TENDER DOCUMENT. SUGGESTED MAKES: NUMERIC, DUBAS, POWER ONE OR EQUIVALENT
30 KVA MODULAR UPS: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 30 KVA MODULAR ONLINE UPS WITH 30 MINUTES BACKUP BATTERY BANK ON FULL LOAD CONDITION WITH NECESSARY STAND AND NECESSARY DC SWITCH (MCCB). BATTERY INTERCONNECTING CABLE AND UPS INPUT COMPLETE TURN-KEY JOB. FOR DETAILED SPECIFICATIONS PLEASE REFER TO PAGE NOS. 15 - 20 OF TENDER DOCUMENT. SUGGESTED MAKES: NUMERIC, DUBAS, POWER ONE OR EQUIVALENT
DX TYPE CEILING MOUNTED DUCTABLE AIR CONDITIONER: SUPPLY & INSTALLATION OF DX TYPE CEILING MOUNTED DUCTABLE AIR CONDITIONER INDOOR UNIT. OUTDOOR UNIT WITH INVERTER SCROLL COMPRESSOR WITH NECESSARY ITEMS - TURN-KEY JOB. FOR DETAILED SPECIFICATIONS PLEASE REFER TO PAGE NOS. 22 - 23 OF TENDER DOCUMENT. SUGGESTED MAKES: LG, VOLTAS, SAMSUNG, LLOYD OR EQUIVALENT MAKES.
EXTERNAL PAINTING: SCRUBBING THE EXISTING PAINTING PROPERLY FOR PREPARING THE SMOOTH SURFACE. APPLYING EXTERNAL WALL CRACK FILLINGS & THE WALL SHALL BE BROUGHT TO PROPER LINE & LEVEL AS PER THE DIRECTIONS OF THE SITE IN-CHARGE. WALL PAINTING: PROVIDING & APPLYING 2 COATS OF EXTERIOR EMULSION PAINT. MAKE: EXTERIOR APEX ULTIMA PAINT. NOTE: PAINT COLOUR WILL BE DECIDED BY C-DOT.
TOTAL
the 3rd dimension architecture
Bidder Name
CRS AND COMPANY
the 3rd dimension architecture
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .