CHIEF ENGINEER PATHANKOT ZONE
HQ CHIEF ENGINEER PATHANKOT ZONE
PROVISION OF SEWAGE TREATMENT PLANT (STP) AT BHADURIYA COMPLEX UNDER GE (SOUTH) PATHANKOT
2026_MES_797054_1
CA NO CEPZ-20/2025-26
Open Tender
Civil Works
Lump-sum
2070 days
GE (South) Pathankot
As per tender document
8 documents required · 8 mandatory
₹2,000
GE (South) Pathankot
₹3.1 L
Yes
3 Nov 2026
3 Nov 2026
16 Dec 2026
3 Nov 2026
9 Dec 2026
2 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SEWAGE TREATMENT PLANT (75 KLD CAPACITY) (STP - 1, 75 KLD) Design, Supply, installation, testing and commissioning of STP of capacity 1x75 KLD based on any suitable technology/method as per Geographical location, temperature differential and rainfall complete with Mechanical, Electrical with tertiary treatment facilities to achieve designed Parameters of Sewage which should be maintained and provide treated sewage Parameters of Sewage. Complete sewage treatment plant to be provided as per the details given in Schedule 'A" Part-I from page No 36 to 39 of CA. | 1 | Each Job | - | - |
| 2 | "Design, supply, installation, testing and commissioning of PLC based SCADA system for 75 KLD STP including PLC panel, HMI, SCADA workstation, field instrumentation, control logic, interlocking, alarm, annunciation, trend logging, report generation, remote monitoring provision and integration with OCEMS/data logger complete as required as per the details given in Schedule 'A" Part-I from page No 40 of CA. | 1 | Each Job | - | - |
| 3 | LT PANNEL FOR 1 X 75 KLD STP
Supplying installation testing and commissioning of extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 100A duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection
(a) Incomming :-(i) 100Amp, 4Pole, MCCB (25KA) with Microprocessor = 01 No (ii) R.Y.B Phase indication lamp with fuse = 1 set. (iii) 0-100 A Digital Ammeter 150/5A Class 10, 1 set (iv) 0-500V Digital Voltometer with Control MCB 1 set (b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type-2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection, R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers ,110m3/hr. (0.50 wc) 5.0HP motor each). (i) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submersible sewer pumps) (ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers pumps (One working+one standby) (For Wet Well cutter Submercible sewer pumps) | 1 | Each Set | - | - |
| 3.01 | Item no. 3 (contd...) (iii) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer) (iv) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps) (v) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) ( For two number Centrifuge feed pumps).
(vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Centrifuge Hydraulic press machine motor) (vii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) ( For two number MBR PERMEATE PUMPS) (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For two numbers Air compressor motor) (ix) 6A TP MCCB 10KA ICS with starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps
and other fitting parts)
(x) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each) | - | - | - | - |
| 3.02 | Item no. 3 (contd...) (xi) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Citric Acid Dosing Pumps) (xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each) (xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps ) (xiv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Mixer ,0.5 HP each) (xv) 6A DP 10 KA for ON line Monitoring System and two number flow meters (xvi) 16A DP 10 KA for Spare -03 No for PLC board. The above panel includes all kind of MCB , MCCB, MPCB, ENERGY METER , Indication Lights , Selector Switches ,Push Button. | - | - | - | - |
| 4 | SEWAGE TREATMENT PLANT (50 KLD CAPACITY)
(STP-2 1x50 KLD )Design, Supply, installation, testing and commissioning of STP of capacity 50 KLD based on any suitable technology/method as per Geographical location, temperature differential and rainfall complete with Mechanical, Electrical with tertiary treatment facilities to achieve designed Parameters of Sewage which should be maintained and provide treated sewage Parameters of Sewage. Complete sewage treatment plant to be provided as per the details given in Schedule 'A" Part-I from page No 41 to 44 of CA. | 1 | Each Set | - | - |
| 5 | "Design, supply, installation, testing and commissioning of PLC based SCADA system for 50 KLD STP including PLC panel, HMI, SCADA workstation, field instrumentation, control logic, interlocking, alarm, annunciation, trend logging, report generation, remote monitoring provision and integration with OCEMS/data logger complete as required as per the details given in Schedule 'A" Part-I from page No 45 of CA. | 1 | Each Job | - | - |
| 6 | LT PANEL FOR 50 KLD STP Supplying installation testing and commissioning of extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 100A duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection) (a) Incomming :-(i) 100Amp,4Pole,MCCB (25KA) with Microprocessor =01 No (ii) R.Y.B Phase indication lamp with fuse =1 set. (iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set (iv) 0-500V Digital Voltometer with Control MCB 1 set (b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , 110m3/hr. ( 0.50 wc) 5.0HP motor each). (i) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submersible sewer pumps) | 1 | Each Job | - | - |
| 6.01 | Item no. 6(contd...)
(ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers pumps (One working+one standby) (For Wet Well cutter Submercible sewer pumps)
(iii) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer) (iv) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps) (v) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) (For two number Centrifuge feed pumps) (vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Centrifuge Hydraulic press machine motor) (vii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) ( For two number MBR PERMEATE PUMPS) (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For two numbers Air compressor motor ) | - | - | - | - |
| 6.02 | Item no. 6(contd...)
(ix) 6A TP MCCB 10KA ICS with starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts) (x) 6A DP MCB 10KA ICS with under/overvoltage protection, overload and short circuit protection,indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each) (xi) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Citric Acid Dosing Pumps) (xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each) (xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps) (xiv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single phase preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. 2 nos: (For Two numbers Hypo Mixer ,0.5 HP each) (xv) 6A DP 10 KA for ON line Monitoring System and two number flow meters
(xvi) 16A DP 10 KA for Spare -03 No for PLC board. The above panel includes all kind of MCB, MCCB, MPCB, ENERGY METER, Indication Lights, Selector Switches, Push Button. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.03 MB
Tender1.pdf
Tender Documents • 4.86 MB
BOQ_894043.xls
BOQ • 0.45 MB
ARCH_DRG.pdf
Additional Documents • 1.39 MB
TD_DRG.pdf
Additional Documents • 16.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .