Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 15 1 1F MAYUR BHANJ ROAD POLICE STATION EKBALPORE KOLKATA 700023 | KOLKATA | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹30.6 L+₹1.5 L (5.02%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹31.2 L+₹2.1 L (7.22%)Rejected-Finance 6A BANAMALI GHOSHAL LANE KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹32.3 L+₹3.2 L (10.8%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹33.0 L+₹3.8 L (13.2%)Rejected-Finance 87 MARIUM MAHAL SADAR BAZAR BARRACK PORE 24 NORTH PGS | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
20 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIVEK TANENIA
GARRISON ENGINEER (CENTRAL) KOLKATA T37 NAPIER ROAD HASTING KOLKATA 700022
SPL REPAIR TO BLDG NO P73 AT GORA BAZAR INSIDE FORT WILLIAM UNDER GE (C) KOLKATA
2023_MES_599740_1
8578/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (CENTRAL) KOLAKTA
₹58,000
Yes
25 Sept 2023
31 May 2023
21 Jun 2023
31 May 2023
20 Jun 2023
14 Jun 2023
31 May 2023 - 13 Jun 2023
Amount
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed.
Taking down Chowkats or Frames, (without taking off Shutter from the Frame) exc. 1.50 Sqm but not exc. 4.00 Sqm Each, complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed.
Taking up or down Steel Water Tubing 15mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, or removing to store, complete all as specified and as directed.
Taking up or down Steel Water Tubing 20mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use or removing to store, complete all as specified and as directed.
Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Material (Soil) exc. 250 m but n exc 500m and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
M&L Plain Cement Concrete type C2 (1:3:6) using 40 mm graded aggregate) in Foundation, Filling and Mass Concrete, complete all as specified and as directed.
M&L Plain Cement Concrete type B1 (1:2:4), using 20mm graded crushed stone aggregate as in surface channels and drains complete all as specified and as directed.
M&L Reinforced Cement Concrete (Design Mix) M-25 in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L Reinforced Cement Concrete (Design Mix) M-25 in Roof Beams, Cantilevers, Bres-summers, Lintels over 1.50 Metre Span, complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
Material and labour chipping of unsound/weak concrete materials of 30mm average thickness from slabs/chajja/ fin fascia etc by any means including tapering all edges making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking material by air blasting or sand blasting incl foreign materials, loose concrete/aggregate etc and disposal of all debris out of MOD land including necessary scaffolding and safety measure complete all as specified and directed by Engr in charge.
Material and labour Chipping of unsound/weak concrete materials of 50mm average thickness from beams/ lintels etc by any means including tapering all edges making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking material by air blasting or sand blasting incl foreign materials, loose concrete/aggregate etc and disposal of all debris out of MOD land including necessary scaffolding and safety measure complete all as specified and directed by Engr in charge.
Material and labour Chipping of unsound/weak concrete materials of 60mm average thickness from coloumn etc by any means including tapering all edges making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking material by air blasting or sand blasting incl foreign materials, loose concrete/aggregate etc and disposal of all debris out of MOD land including necessary scaffolding and safety measure complete all as specified and directed by Engr in charge.
M&L Removing concrete all around reinforcement including behind of reinforcement bars to give an average clearance of 25mm (but not less than 15mm clear air gap) by manual methods (hammering and using wire brushes, chieselling etc.) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcement bars by emery paper and cleaning the area throughly by water and alllow it to dry as per manufacturer's instructions to provide totally rust free finished steel surfaces, length of reinforcement bars cleared of concrete shall be measured for payment including upto four storey height of building upto 12mm dia of bars complete all as specified and as directed by the Engr-in-Charge.
Material and labour Removing concrete all around reinforcement including behind of reinforcement bars to give an average clearance of 25mm (but not less than 15mm clear air gap) by manual methods (hammering and using wire brushes, chieselling etc.) and applying alkaline rust removing chemical followed by removing rust including from behind the reinfircement bars by emery paper and cleaning the area throughly by water and alllow it to dry as per manufacturer's instructions to provide totally rust free finished steel surfaces, length of reinforcement bars cleared of concrete shall be measured for payment including upto any height of building above 12mm dia of bars but upto 20mm dia bars complete all as specified and as directed by the Engr-in-Charge.
Material and labour Cleaning of exposed concrete surfaces of lightly sticking materials including foreign materials, loose concrete/ aggregate etc and disposal of all debris upto distance of 50 m and applying single coat of epoxy bond adhesive on prepared non metallic surfaces (existing surface) by using brush as per manufacturers instruction / specification upto four storey of building complete all as specified and as directed by the Engr-in-Charge.
Supply and application Epoxy Zinc rich primer on the prepared reinforced surface by brush, the primer shall have a minimum specific gravity 1.75, minimum wet film thickness/coat 100 microns & dry film thickness/coat 40 microns. Minimum adhesive bond strength with steel is 1.5 N/mm2 upto upto four storey height of building complete all as specified and as directed by the Engr-in-Charge.
Materials and labour Introducing new reinforcement bars for structural connections in RCC beam, lintels, columns and slabs etc including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm upto 200mm including power drilling, fixing the reinforcement in position using epoxy after dusting of loose dust by blowing air, sealing the same with epoxy cartridges etc as per manufacturer instruction for upto 12mm dia of bar complete all as specified and as directed by the Engr-in-Charge.
Materials and labour Introducing new reinforcement bars for structural connections in RCC beam, lintels, columns and slabs etc including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm upto 200mm including power drilling, fixing the reinforcement in position using epoxy after dusting of loose dust by blowing air, sealing the same with epoxy cartridges etc as per manufacturer instruction for exc 12mm dia of bar but n.exc 20mm dia of bars complete all as specified and as directed by the Engr-in-Charge.
Supply and application free flow non-shrink cementitious micro concrete to the affected beam, column etc. 60mm thickness (average) where major spalling has taken place even the core of concrete affected. The Micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, Minimum tensile strenght 2 N/mm2 @ 28 days, minimum Flexural strength 5 N/mm2@ 28 days tested as per BS 4551-80, Expansion characterstics Unrestrained expansion as per ASTM C827-1987 1 to 4%. including necessary formwork, upto any height including necessary scaffolding and safety measures complete all as specified and as directed by the Engr-in-Charge.
Supply and application free flow non-shrink cementitious micro concrete to the affected beam, column etc. 50mm thickness (average) where major spalling has taken place even the core of concrete affected. The Micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, Minimum tensile strenght 2 N/mm2 @ 28 days, minimum Flexural strength 5 N/mm2@ 28 days tested as per BS 4551-80, Expansion characterstics Unrestrained expansion as per ASTM C827-1987 1 to 4%. including necessary formwork, upto any height including necessary scaffolding and safety measures complete all as specified and as directed by the Engr-in-Charge.
Supply and application Two component structural grade polymer modified reinstatement mortar where local spalling has taken place or shuttering is not possible. The Mortar can be applied from a minimum of 5mm to 15mm thickness in smaller vertical pockets and upto 100 mm thickness in horizontal applications. The Mortar should have a minimum compressive strength 12 N/mm2 in 1 day and 4 5N/mm2 in 28 days. Minimum Flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementitous systems to be mixed with cement slurry before the application of microconcrete to be used @ 6 lit/bag of cement. The bonding agent should have minimum compressive strength 24 N/mm2 Minimum Tensile strength 3.5 N/mm2, Minimum Flexural Strength 6.5 N/mm2 including necessary scaffolding and safety measures complete all as specified and as directed by the Engr-in-Charge.
M&L Cutting Chases in Brick Walls or any position where directed for Concealed Water Tubing/ conduit, Pinning in, Making Good to facings where required and Pointing in Cement Mortar 1:3 to making good, cutting not exc. 10 Cm girth, complete all as specified and as directed.
M&L Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work pulverizes fly ash bricks ,Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
M&L Formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed.
M&L Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed.
M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed.
S&F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed.
S&F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make and Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed.
S&F Fixed type partly glazed, partly gauged. Solid PVC ventilator including 3mm thick frosted glass pane, 0.36mm dia & 1.4mm aperture stainless steel wire net, glazing clip, fastener etc complete all as specified and directed.
S&F Rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed.
S&F Pre-painted colour galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Stripping of old tarfelt including layer of plaster or morter of any type of treatment carefully from roof surfaces (without damage of roof) and roughening of surface of old concrete roofing by picking, sweeping, cleaning and washing down with water to remove dust complete all as specified and directed.
M&L 20mm thick screed bed or bedding layer in CM 1:4 surface finished even and smooth without using extra cement for padding including neat cement slurry @ 3.00 kg /sqm complete all as specified and directed.
M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer's instructions, complete all as specified and as directed :- (a) Preparing and cleaning of fully dry surface as per IS:3067-1966. (b) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.50 Litre per Sqm. (c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction. (d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane.
M&L False ceiling with 'E' board "Classic" , reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium powder coated snap grid to support the boards/files with aluminium anodised main 'T' section 35mm x 25mm x 1.50mm, cross tee 25mm x 25mm x 1.50mm thick and aluminium angle 25mm x 25mm x 1.50mm as on edges/sides and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces including taking down old unserviceable one complete all as specified and as directed.
M&L Hangers 6.0 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of Ceiling cleats made out of GI Flat 40x3 mm size 60mm long and Expansion Hold Fasteners 12.5mm dia, 60mm long, complete all as specified and as directed.
S&F Aluminium alloy Handle 150mm long, Extruded Section, Fabricated type, anodized and fixed, complete all as specified and as directed.
S&F Aluminium anodized, Barrel Tower Bolt 200mm long, Extruded Section and fixed, complete all as specified and as directed.
S&F Mild Steel Butt Hinges, size of Hinges 100mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed.
M&L Cement Concrete type C2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
S&F Machine cut kota stone slab 20-25mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 20 mm thick backing layer in cement mortar (1:4) including rubbing and polishing complete all as specified and as directed.
M&L Prepolished cement concrete designers chequered tiles of size 300 x 300 x 20 to 25 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick screed bed in cement mortar 1:6 for laying floor finishes and including dismantling of chequered tiles . complete all as specified and directed.
M&L Coloured vitrified ceramic floor tiles double/ ultra charge,10 mm thick (square/rectangular) area of each tile exc 0.42 sqm but n. exc. 1.00 sqm as in floor etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor make incl 15 mm thick screed bed or bedding of layers in CM 1:4 complete all as specified and as directed.
M&L Coloured vitrified ceramic tiles double/ ultra charge,10 mm thick (square/rectangular) area of each tile exc 0.42 sqm but n. exc. 1.00 sqm as in floor etc) on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed.
M&L Coloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors over and including 15mm thick screed bed/bedding layer in CM 1:6 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor complete all as specified and as directed.
M&L Glazed Ceramic Coloured 450 x 350 x 7.0mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed.
M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges,including dismantling of stone slabs and tiles of any description or thickness complete all as specified and as directed.
M&L Rendering 20mm thick in Cement Mortar on fair faces of brick work or concrete surface of wall in two layer, first layer 10 mm thick in cement morter (1:4) and top layer 10mm thick in cement morter (1:4) using water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and as directed. . (NOTE:-WPC shall be measured and paid separately)
M&L Rendering 15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed.
M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc. finishing Plastered Surfaces Even and Smooth, without using Extra Cement. complete all as specified and as directed.
"Supply only" liquid water proofing compound (ISI marked) complete all as specified and directed. Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA
M&L Preparing new plastered surfaces of walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsion Paint Weather Coat over a coat of Primer (as per Manufacturer’s instructions), and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Complete removal of old decorated surfaces of Walls and applying Two Coats of Exterior Emulsion Paint Weather Coat over a coat of Primer (as per Manufacturer’s instructions), and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
S&F 18 mm thick toughned glass with etching (engraving picture, names or figures of any size) for glazed fixed including aluminium frame with nececcary washer fixing clips, rubber gasket etc with all accessories complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
S&F Vitreous china wash hand basin,oval under counter base white size 530x440x200mm flat back type including 32mm dia Brass Chromium Plated Waste Fitting and 15mm dia PVC connector pipe and tap , a pair of Cast Iron Brackets duly painted Stand including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items complete all as specified and as directed. Make : Cera Cat part No.S2020145 or equivalent make as specified in the particular specfication.
S&F 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections including taking down/out unserviceable one complete all as specified and as directed. Make : Parryware Model No- E-8090, Cera cat part No CONGO B1010109 or equivalent model as specified in Particular Specification here in after.
S&F Brass chromium plated fancy type pillar tap screwed for 15 mm bore of pipe etc.incl necessary fittings & fixtures as in repair complete all as specified & directed. Make:- Essco Cat pat No DLX 507 or equivalent make as specified in the particular specfication.
S&F 125 mm dia brass chromium plated shower rose with or without swivels joint for fixing to 15 mm bore pipe etc complete including taking down old one complete all as specified and directed. Make:- Essco Cat pat No EOS-541N or equivalent make as specified in the particular specfication.
S&F Vitreous China White Squatting Pan ‘ORISSA’ Pattern, size 580x440mm with ‘P’ or ‘S’ Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan including Flushing Cistern and Flush Pipe, fixing with and including provision of cement Concrete Bedding including Taking down/out unserviceable WC Pan and connected Items, complete all as specified and as directed. Make - Parryware Model No-C0297, or equivalent make specified in the particular specification
S&F Chromium plated Bib taps for 15 mm bore of pipe incl necessary fittings & fixtures as in repair complete all as specified & directed Make : Essco (DLX-511 or equivalent make specified in the particular specification
S&F Chromium Plated soap dish incl necessary fittings & fixtures complete all as specified & directed. (Make:- Jaguar CAN-1151N) or equivalent make specified in the particular specification.
S&F Toilet paper holder of brass chromium plated fixed to walls with chromium plated CP brass screw complete all as specified and directed. Make : Prayag or equivalent make specified in the particular specification
S&F Brass chromium plated fancy type stop cock screwed for 15 mm bore of pipe etc.incl necessary fittings & fixtures as in repair complete all as specified & directed. Make:- Essco Cat pat No DLX 513B or equivalent make as specified in the particular specfication.
S&F Brass chromium plated fancy type stop cock (concealed type) screwed for 15 mm bore of pipe etc.incl necessary fittings & fixtures as in repair complete all as specified & directed. Make:- Essco Cat pat No DLX 514AKN or equivalent make as specified in the particular specfication.
S&F Chromium Plated tublar towel rail 600 mm long and 20 mm dia with bracket at both ends and fixed with chromium plated brass screw and wooden/plastic cleats as in repair complete all as specified and directed. Make : Essco/Prayag or equivalent make as specified in Particular specifications.
S&F Cast Iron Soil, Waste and Vent Pipes 100mm bore (dia), Sand Cast, in any Length with or without Ears, with Cement Joints in Cement Mortar 1:1, fixed to Walls, complete all as specified and as directed.
S&F Cast Iron Bend 100mm bore (dia), any radius, Disminishing Pieces or Tapers (Large Bore measured) and fitted with Oval Access Doors including Jointing with Cement Mortar 1:1, complete all as specified and as directed.
S&F Cast Iron Branch Piece 100mm bore (dia) single (equal or unequal), ordinary or inverted (spigot or socket type) with Parallel Branches fitted with Oval Access Door including Jointing with Cement Mortar 1:1, complete all as specified and as directed.
S&F Cast Iron Tee 100mm bore (dia) single (equal or unequal), ordinary or inverted (spigot or socket type) with Oval Access Door including Jointing with Cement Mortar 1:1, complete all as specified and as directed.
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as directed by Engineer-in-Charge.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of Sch A
All as per item No here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. here-in-before but one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
M&L Point wiring with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit 20mm dia medium duty with all fittings and accessories of concealed (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp socket outlet on independent board complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of sch A
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 1 Module/ 2 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 3 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls.6 Module complete for modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 2 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 3 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 6 modules complete all as specified and as directed.
S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular switch socket combination 3 pin 5 Amps 230 volts flush type,3 module complete all as specified and as directed.
S&F Modular socket out let 3 pin 5 Amps flush type 2 module complete all as specified and as directed.
S&F Modular switch socket outlet multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch complete all as specified and as directed.
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth with cement morter 1:3 complete all as specified and as directed.
S&F LED luminaire 2ftx2ft 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete including taking down old unserviceable one.complete all as specified and directed. Make:Magik cat no PCVP036C or Philips cat no. R380B-LED36S-6500-G5-L60W60PSU-OD orequivalent Bajaj/Havells as specified in the particular specification.
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
S&F Sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete 240 volts complete all as specified and as directed.
S&F MCB TPN DB double door made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed.
S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed.
S&F MCB DP 63 amps 240 volts 'C' curve breaking capacity 10 kA complete all as specified and as directed.
S&F Isolator 63 Amps, 415 Volts , 'Triple and neutral with rupturing capacity 10 kA complete all as specified and as directed.
Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipe including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
S&F Exhaust fan AC single phase 240 V of size 300 mm sweep with louver specially designed by toilet/bathroom in domestic ventilattion metal body and blade, powder coated metalic finishes heavy duty motor, protective bird guard complete all as directed and specifed. Make:- VENTLAIR DSP of Havells/CG/Usha or equivalent
S&F wall mounted fan AC single phase 240 V of size 450 mm sweep(SSTORM 2), metal body and blade, powder coated metalic finishes heavy duty motor, complete all as directed and specifed.
Material and labour ACP board along with MS Frame board of size 19 ft total ACP Size of 65 sqft including all necessary fixing arrangement and tools and plants complete all as directed by Engr-In-Charge
Material and labour for LED liquid letter of size 12 inches each with aluminium side channel having raising of 2 inches inside LED module alongwith power supply including all neccsary fixing arrangment and tools and plants complete all as directed by Engr in Charge
Material and labour for pillar polymer base with MS frame and vinyl print pasting on one side of size 24"x24" including all necessary fixing arrangment and tools and plants complete all as directed by Engr -in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
SUDHA ENTERPRISES
AUTO ELECTRICALS
BHASKAR SUPPLY AGENCY
JHAWAR SUPPLIERS
CIVCON
M/S AVIJEET INTERNATIONAL
JAY MA TARA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .