H11259 of 2023-24. Providing replacement of existing old Air Conditioning system by new Air-conditioning system for the CT Scan and MRI rooms of Radiology Department at ground floor of Main Bldg., Sir J. J. Group of Hospitals, Byculla, Mumbai.
2024_PWDM_1017901_1
Quatation/17/JJ/3
Open Tender
Electrical Works
Item Rate
90 days
JJ Subdivision
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
7 Mar 2024
26 Feb 2024
6 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
Amount
Supply installation testing & commissioning of 11 TR capacity Air cooled Ductable Units suitable to work with R-410A/ CFC free refrigerant, working with 440 Volts, complete with 1 Blower section including Blower, Scroll, shaft, drive pulley package, Evaporator coils with twin circuits. The unit shall also be consists of 2 nos x 5.5 TR capacity Outdoor Condensing unit equipped with hermatic scroll compressor and inbuilt factory fitted Programmable, Microprocessor controller based electrical panel & associated controls.
Supply and installation testing commissioning of with capacity 77 KW and 22 TR Air cooled Chiller, having safety High Pressure switch Low chiller , Lower pressure Switch , flow switch ,Antifreeze Protection, Alarm with Buzzer, Crankcase Heater, Overload for pump, Circuit breaker for compressor, ( Single phase/ phase reverse protection only for scroll compressor , Cooler leaving water temperature 6.7C (44F)and cooler entering temperature 12.2C (54 F) and Cooler fouling 0.0001 f. fthr /Btu, 35C (95 F) Ambient temperature .having Scroll compressor of 12.Kw /02 No’s Plate type heat exchanger - 02 No’s Air Cooled Fan 32 inch 2 no’s Rated flow 200/52.4 LPM / USGPM with Refrigerant R-22 / R-410/ R-32 etc. Make Blue Star , Carrier and Equivalent PISB Cantoning valve having M.s Powder Coating with Digital Display Showing pressure and temperature pressure to and from the system.
Gil Airconditioning And Refrigeration Services
NEW NATIONAL AIRCONDITIONING CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .