Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.8 L+₹4.9 L (13.9%)Rejected-Finance JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹40.6 L+₹5.7 L (16.4%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹45.3 L+₹10.3 L (29.6%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
6 Oct 2022, 6:00 pmClosed
Garrision Engineer
GE (Utilities) Udhampur, PO- Garhi, Udhampur 182121
Repair/Replacement of CI/DI/MS pipe lines of various sizes sluice valves, NRV, ARV in certain different locations under GE (Utilities) Udhampur.
2022_MES_550684_1
GE/U-44/2022-23
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
GE(Utilities) Udhampur
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹97,000
Yes
6 Dec 2022
8 Sept 2022
8 Oct 2022
8 Sept 2022
6 Oct 2022
22 Sept 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of hard/dense soil. Complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested complete, all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engr-in-Charge.
Taking up or down old unseviceable GI pipe of size 150 mm dia including all fittings complete all as specified and directed by Engr-in-Charge.
All as per serial item No 4.00 here-in-before but of 100 mm dia.
All as per serial item No 4.00 here-in-before but of 80 mm dia.
All as per serial item No 4.00 here-in-before but of 50 mm dia.
All as per serial item No 4.00 here-in-before but of 40 mm dia.
All as per serial item No 4.00 here-in-before but of 25 mm dia.
All as per serial item No 4.00 here-in-before but of 20 mm dia.
All as per serial item No 4.00 here-in-before but of 15 mm dia.
GI pipes of size 150 mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified and directed by Engr-in-Charge.
All as per serial item No 12.00 here-in-before but of 100 mm dia.
All as per serial item No 12.00 here-in-before but of 80 mm dia.
All as per serial item No 12.00 here-in-before but of 50 mm dia.
All as per serial item No 12.00 here-in-before but of 40 mm dia.
All as per serial item No 12.00 here-in-before but of 25 mm dia.
All as per serial item No 12.00 here-in-before but of 20 mm dia.
All as per serial item No 12.00 here-in-before but of 15 mm dia.
Refixing GI/CI pipe obtained from Item No. 04 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 150 mm dia complete including main branch connections complete all as specified and directed by Engr-in-Charge.
All as per serial item No 20.00 here-in-before but of 100 mm dia obtained from item No. 05.
All as per serial item No 20.00 here-in-before but of 80 mm dia obtained from item No. 06.
All as per serial item No 20.00 here-in-before but of 50 mm dia obtained from item No. 07.
All as per serial item No 20.00 here-in-before but of 40 mm dia obtained from item No. 08.
All as per serial item No 20.00 here-in-before but of 25 mm dia obtained from item No. 09.
All as per serial item No 20.00 here-in-before but of 20 mm dia obtained from item No. 10
All as per serial item No 20.00 here-in-before but of 15 mm dia obtained from item No. 11
Cast iron sluice valve (in replacement) suitable of size 300 mm (PN 1.6) ISI Marked with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing. Item Art. No 1079B, complete all as specified and directed by Engr-in-Charge. Make: Leader or equivelant in Kirloskar/BVI/BIR.
All as per serial item No 28.00 here-in-before but of size 250 mm dia.
All as per serial item No 28.00 here-in-before but of size 200 mm dia.
All as per serial item No 28.00 here-in-before but of size 150 mm dia.
All as per ser item 28 here-in-before but of size 100 mm dia.
All as per serial item No 28.00 here-in-before but of size 80 mm dia.
Cast iron non return valve (in replacement) of suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing. Item Art No : 1083C complete all as specified and directed by Engr-in-Charge. Make: Zoloto or equivelant in Kirloskar/BVI/BIR/Leader.
All as per serial item No 34.00 here-in-before but of size 100mm dia.
All as per serial item No 34.00 here-in-before but of size 80mm dia.
Cast iron air release valve (in replacement ) with two air outlets of size 100 mm dia including all jointing materials like high pressure rubber gasket nuts, bolts, washers with arrangement for fixing, including taking down existing.Item Code No/ Size CI 026/N complete all as specified and directed by Engr-in-Charge. Make: Leader or equivelant in Kirloskar/BVI/BIR.
All as per serial item No 37.00 here-in-before but size of 80mm dia.
Repair to old sluice valve of size 200 mm dia for check nut, spindle, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing complete all as specified and directed by Engr-in-Charge.
All as per serial item No 39.00 here-in-before but of 150 mm dia.
All as per serial item No 39.00 here-in-before but of 100 mm dia.
All as per serial item No 39.00 here-in-before but of 80 mm dia.
Repair to leaking run lead joints in CI/DI spigot and socket end pipe line of 100 mm bore by providing new lead ,using good quality spun yarn, including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and at any depth complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra fittings/pipe will be measured and paid separately.
All as per serial item No 43.00 here-in-before but of dia 150 mm bore pipe.
All as per serial item No 43.00 here-in-before but of dia 200 mm bore pipe.
Repair to leaking GI pipe line of size 50 mm to 80 mm bore by providing necessary fitting such as socket, Tee, Elbow,etc including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and any depth complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra pipe will be measured and paid separately.
All as per serial item No 46.00 here-in-before but of size 20mm to 40mm bore pipe.
Repair to leaking flanged/circular welding joints of 100 to 200 mm bore MS/GI pipe line by providing rubber or fiber board gasket, new flanges if required at site, nut bolts, washers and welding works where required etc, including necessary excavation, returning filling in trenches in any type of soil, bailing out water, and any depth complete all as specified and directed by Engr-in-Charge. Note:- Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechnical excavation work and man power at site requirement with making good distrubed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra fittings/pipe will be measured and paid sepately.
All as per serial item No 48.00 here-in-before but of dia 250 to 300 mm bore pipe.
Cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary exacavation and earth work including repairing the same as per existing complete all as specified and directed by Engr-in-Charge.
PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pole & stay complete as specified and directed by Engr-in-Charge.
Premix ready mix road repair patching compound for instant road repair manufactured with a blend of bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg complete all as specified and directed by Engr-in-Charge.
Water proof fountain light of capacity 10 watt having warm light output complete all as specified and directed by Engr-in-Charge.
Multi core PVC insulated and FR-LHS PVC round sheatehed, copper conductor(flexible) industrial cable 1100 volt grade confirming to Is 694 , 1.5 sqmm 1 core including suitable size PVC conduit laid complete all as specified and dirwcted by Engr in Charge.
Multi core PVC insulated and FR-LHS PVC round sheatehed, copper conductor(flexible) industrial cable 1100 volt grade confirming to Is 694 , 2.5 sqmm 1 core including suitable size PVC conduit laid complete all as specified and dirwcted by Engr in Charge.
The nipple brass nozzle as per sample including removal of existing unsv one all as specified and directed by Engr-in-Charge.
Cast iron fittings for spigot and socket ends for pressure pipe for water mains such as bends, tapers, tee pieces single branch, cross collar, caps and plugs suitable for 200 to 300 mm bore, all specifications as per IS-1538 (Pt-1 to 23)-1976 and all as specified and directed by Engr-in-Charge.
All as per serial item No 57.00 above but upto 150mm bore.
Supply fabrication and fixing MS joints like bends, Tee, Tapers, collars, elbow, tail piece (any type) caps, plugs for 80 mm to 300 mm bore pipe complete all as specified and directed by Engr-in-Charge.
Butterfly valves, 80mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
Gun-metal, globe or gate valves, 50mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified and directed by Engr-in-Charge.
Gun-metal, globe or gate valves, 40mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
Gun-metal, globe or gate valves, 25mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified and directed by Engr-in-Charge.
Gun-metal, globe or gate valves, 20mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified and directed by Engr-in-Charge.
Gun-metal, globe or gate valves, 15mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
GI fittings medium grade ISI marked including complete all as required at site complete all as specified and directed by Engr-in-Charge.
Elbow 15mm.
Elbow 20mm.
Elbow 25mm
Elbow 40mm
Elbow 50mm
Elbow 80mm
Socket 15mm
Socket 20mm
Socket 25mm
Socket 40mm
Socket 50mm
Socket 80mm
Union 15mm
Union 20mm
Union 25mm
Union 40mm
Union 50mm
Union 80mm
Elbow reducer 20 x 15mm
Elbow reducer 25 x 20mm
Elbow reducer 40 x 25mm
Socket reducer 25x20mm
Socket reducer 40x25mm
Socket reducer 40x20mm
Socket reducer 50x25mm
Nipple 15 x50mm
Nipple 15 x100mm
Nipple 20 x50mm
Nipple 20 x100mm
Nipple 25 x 50mm
Nipple 25 x 100mm
Nipple 40 x 50mm
Nipple 40 x 100mm
Nipple 50 x 50mm
Nipple 50 x 100mm
Tee 15mm
Tee 20mm
Tee 25mm
Tee 20x15mm
Tee 25x20mm
Tee 40x15mm
Tee 40x20mm
Tee 40x25mm
Tee 50x25mm
Dead plug 15mm
Dead plug 20mm
Dead plug 25mm
Dead plug 40mm
Dead plug 50mm
Lead wool
Taking up or down PVC PP-R bore of pipe 90mm dia including all fittings complete all as specified and directed by Engr-in-Charge.
All as per serial item No 67.00 here-in- before but size of 75 mm dia.
All as per serial item No 67.00 here-in- before but size of 50mm dia.
All as per serial item No 67.00 here-in- before but size of 25mm dia.
All as per serial item No 67.00 here-in- before but size of 20mm dia.
Supply,laying, jointing & testing of PVC PP-R pipe having outer dia 90mm of pressure rating PN 16 /SDR 7.4 in three layer with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply,laying, jointing & testing of PVC PP-R pipe having outer dia 75mm of pressure rating PN 16 /SDR 7.4 in three layer with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply,laying, jointing & testing of PVC PP-R pipe having outer dia 50mm of pressure rating PN 16 /SDR 7.4 in three layer with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply,laying, jointing & testing of PVC PP-R pipe having outer dia 25mm of pressure rating PN 16 /SDR 7.4 in three layer with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply,laying, jointing & testing of PVC PP-R pipe having outer dia 20mm of pressure rating PN 16 /SDR 7.4 in three layer with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
Taking up or down CI/DI/MS water mains pipe 300 mm bore (including all fittings), with flanged/welded butt joint/ spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed by Engr-in-Charge.
Refixing MS/DI/CI pipe obtained from item No. 77.00 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 300 mm bore complete inlcuding main / branch connections all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing MS ERW pipe class 'B' of bore 300 mm having wall thickness 6 mm with permissible tolerance + 10% conforming to IS-3589, ISI marked alongwith circular welding joints laid in trenches/ along road/ on surface/ slopes/pillars/ culverts/ causeways etc, complete all as specified directed by Engr-in-Charge.
Supply of Copper Sulphate for swimming pool water cleaning and colouring complete all as specified and directed by Engr-in-Charge.
LED underwater lights (in replacement) of cap not less than 34 watt and 12 V DC supply, IP-68 protection of external body size 225 mm dia with independent control gear complete all as specified and directed by Engr-in-Charge.
Supply and laying of flexible pipe of 15/20 mm dia used for wiring purpose complete all as specified and directed by Engr-in-Charge.
UPVC Butterfly valve in replacement) of size 140 mm dia PN 16 complete all as specified and directed by Engr-in-Charge.
Repair to leakage of 110 to 160 mm PVC pipe including all necessary fitting such as Tee, Socket, jointing material, etc complete all as specified and directed by Engr-in-Charge.
PVC pipe of size 110 mm dia class 3 (as per existing) including all necessary fitting such as bends, Socket, jointing material, etc complete all as specified and directed by Engr-in-Charge.
PVC pipe of size 140 mm dia class 3 (as per existing) including all necessary fitting such as bends, Socket, jointing material, etc complete all as specified and directed by Engr-in-Charge.
PVC pipe of size 160 mm dia class 3 (as per existing) including all necessary fitting such as bends, Socket, jointing material, etc complete all as specified and directed by Engr-in-Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .