Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC GARH ROAD MEERUT UTTAR PRADESH 250002 INDIA | MEERUT | UTTAR PRADESH | 250002 | ₹9.8 L Quoted ₹10.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹11.7 L+₹1.7 L (17.2%)Rejected-AOC 25 13 1 AMBEGAON PATHAR PUNE 411046 | PUNE | MAHARASHTRA | 411046 | ₹11.7 L+₹1.7 L (17.2%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹12.8 L+₹2.9 L (28.8%)Rejected-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | ₹12.8 L+₹2.9 L (28.8%) | L3 | Rejected-AOC Not Lowest |
Tender Value
₹10.6 L
EMD Value
₹21,100
Closing Date
25 Apr 2020, 6:00 pmClosed
GE Guwahati
GE GUWAHATI PO SATGAON DISTT KAMRUP - 781027
REPAIR/MAIN AND CERTAIN ALLIED WORKS TO CENTRAL AC PLANT AT BASISTHA UNDR GE GUWAHATI
2020_MES_316189_3
GE/GUW/T/56/2019-20/8909
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Guwahati
As per tender documents
7 documents required · 7 mandatory
₹500
GE Guwahati
₹21,100
Yes
17 Jun 2020
7 Apr 2020
27 Apr 2020
7 Apr 2020
25 Apr 2020
13 Apr 2020
7 Apr 2020 - 11 Apr 2020
Amount
Materials and Labour for opening of suction line of DX cooler (Evaporator) shell tube of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR, screw Type Chiller, repair for leakage of cooling coil with MS threaded bullets or as recommended by manufacturer, Complete all as specified and directed.
Materials and Labour for de-scaling of condensor of screw type chiller unit of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR, by using chemical solution as recommended by manufacturer with rods and wire brushes, complete all as specified and directed .
Materials and Labour for leakage testing of refrigerant gas pipe lines (Suction & delivery) of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR Screw type Chiller with nitrogen pressure, including making good, rectification of leakage, flushing and vacumising as required complete as directed.
Materials and Labour for charging of refrigerant gas R-22 including opening and re-assembling of connected acessories of central AC plant of capacity 75 TR , complete all as specified and directed .
Materials and Labour for Compressor oil, type 5 GS (White), duly filled for top up to central AC plant of capacity 75 TR, complete all as specified and as per manufacturer's recommendation and as directed .
Suppy and Fixing in repair, Solenoid coil of exsiting make for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Suppy and Fixing in repair, Sensor Set of exsiting make for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Suppy and Fixing in repair, Pressure transducer of exsiting make for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR , complete all as specified and directed
Suppy and Fixing in repair, Catchall core of exsiting make for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Suppy and Fixing in repair, Controller and display set for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR Screw type Chiller unit of existing make complete all as specified and directed .
Suppy and Fixing in repair, installation of new software in controller and display unit for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Materials and Labour for servicing of main air handling unit (AHU) for Central AC plants (AC Plant Make - Blue star) of capacity 75 TR by opening of AHU, cleaning of cooling tubes, cleaning of drain pipe ,greasing to bearings of blower shaft-02 Nos, cleaning/replacement of filters for supply air grills and return air grills, ensuring the tightness, pullies in blower and motor, cleanig of blower wheel fins and re-fixing in position all as specified and directed. Note - New Air filter shall be measured and paid separately under relevant items as "supply only".
Supply only Air filter for AHU (24"x24") as per existing make for incorporation in work complete all as specified and directed.
Supply only Air filter for AHU (24"x12") as per existing make for incorporation in work complete all as specified and directed.
Suppy and Fixing in repair Humidity thermostate of existing make for AHU unit of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Suppy and Fixing in repair Humidity Controller of existing make for AHU unit of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Suppy and Fixing in repair Actuator valve of existing make for AHU unit of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Suppy and Fixing in repair Canvas for AHU of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete all as specified and directed
Materials and Labour for Servicing and de-scaling of FRP cooling tower induced draft counter flow of dimension 2855x3100x3850mm of Central AC plants (AC Plant Make - Blue star) of capacity 75 TR complete with chemical solution as recommended by manufacturer with rods and wire brushes complete all as specified and directed.
Disconnecting electrically and opening of cooling tower fan motor (induction type) of cap 7.5 HP, 415 volts, 50 Hz, refixing in existing location after servicing, greasing and varnishing of and making electrical connections complete all as directed.
Disconnecting and dismantling of condensor cooling water pump set with motor of capacity 7.5 HP, 415 Volts, 50 Hz of Central AC plants of 75 TR capacity (Centrifugal type of Make- Kirloskar ) transporting to authorized civil workshop for repair, taking out defective spare/parts and replacement of the same with new one reassembling and transporting back to site duly repaired including servicing, greasing etc as required and fixed in position including testing complete all as directed. Note - New spare/parts shall be measured and paid separately under relevant items as "supply only".
Supply only Ball bearing as per existing number for incorporation in work complete all as directed.
Supply only Gun metal pump impeller as per existing make and model for incorporation in work complete all as directed.
Supply only Gland paking as per existing for incorporation in work complete all as directed.
Disconnecting electrically, mechanically and dismantling of chiller water pump set (Centrifugal type of make KIRLOSKAR) of capacity 12.5 HP, 415 Volts, 50 Hz of Central AC plant, servicing, greasing, varnishing of the same, refixing in existing position including making necessary electrical connection complete all as specified and directed. Note - New spare/parts shall be measured and paid separately under relevant items as "supply only".
Supply only Ball bearing as per existing number for incorporation in work complete all as directed.
Supply only Gun metal pump impeller as per existing make and model for incorporation in work complete all as directed.
Supply only Gland paking as per existing for incorporation in work complete all as directed.
Materials and Labour disconnecting electrically and mechanically and dismantling of AHU blower fan motor of capacity 12.5 HP, 415 Volts, 50 Hz (Make Cromption greaves) of Central AC plants, servicing, greasing, varnishing of the same, refixing in existing position including making necessary electrical connection complete all as specified and directed.
Materials and Labour for disconnecting electrically and mechanically and dismantling of AHU blower fan motor of capacity 10 HP, 415 Volts, 50 Hz (Make Cromption greaves) of Central AC plants, servicing, greasing, varnishing of the same and refixing in existing position including making necessary electrical connection complete all as specified and directed.
Materials and Labour for disconnecting electrically and mechanically and dismantling of AHU blower fan motor of capacity 5 HP, 415 Volts, 50 Hz (Make Cromption greaves) of Central AC plants, servicing, greasing, varnishing of the same and refixing in existing position including making necessary electrical connection complete all as specified and directed.
Materials and Labour for disconnecting electrically and mechanically and dismantling of AHU blower fan motor of capacity 3 HP, 415 Volts, 50 Hz (Make Cromption greaves) of Central AC plants, servicing, greasing, varnishing of the same and refixing in existing position including making necessary electrical connection complete all as specified and directed.
Taking out old burnt out winding of motor and rewinding of electric motor (For Chiller water pump of make- Kirloskar) of capacity 12.5 HP, 415 V, 50 Hz with new super enamelled copper wire of suitable size as per existing gauge including insulating material, heating, varnishing, etc as required, re-assembling and fitted in position and testing complete all as directed.
Taking out old burnt out winding of motor and rewinding of electric motor (For condensor cooling water pump of make- Kirloskar) of capacity 7.5 HP, 415 Volt, 50 Hz with new super enamelled copper wire of suitable size as per existing gauge including insulating material, heating, varnishing, etc as required, re-assembling, fitted in position and testing complete all as directed .
Taking out old burnt out winding of motor and rewinding of electric motor (For AHU blower fan motor of make- Cromption greaves) of capacity 12.5 HP, 415 Volts, 50 Hz with new super enamelled copper wire of sitable size as per existing gauge including insulating material, heating, varnishing, etc as required, re-assembling, fitted in position and testing complete all as directed .
Taking out old burnt out winding of motor and rewinding of electric motor (For AHU blower fan motor of make- Cromption greaves) of capacity 5 HP, 415 Volts, 50 Hz with new super enamelled copper wire of sitable size as per existing gauge including insulating material, heating, varnishing, etc as required, re-assembling, fitted in position and testing complete all as directed .
Taking out old burnt out winding of motor and rewinding of electric motor (For AHU blower fan motor of make- Cromption greaves) of capacity 3 HP, 415 Volts, 50 Hz with new super enamelled copper wire of sitable size as per existing gauge including insulating material, heating, varnishing, etc as required, re-assembling, fitted in position and testing complete all as directed .
Suppy and Fixing in repair Cast iron butterfly valve of size 25mm dia, conforming to IS 13095 including providing insulating materials on affected /disturbed portion of water pipe line complete all as specified and directed .
Suppy and Fixing in repair 'V' belt for blower motor of AHU of Central AC plants (AC Plant Make - Blue star) as per existing type and make complete all as specified and directed .
Suppy and Fixing water control valve type 100 NBCIH, 100mm bore butterfly type for pipe line of Central AC plants (AC Plant Make - Blue star) as per existing type and make complete all as specified and directed .
Suppy and Fixing in repair Air release valve 25 mm bore, double chamber conforming to IS 14845 complete all as specified and directed .
Suppy and Fixing in repair, thermostatic expansion valve for Central AC plants (AC Plant Make - Blue star), 75 TR capacity as per existing make complete all as specified and directed .
Suppy and Fixing in repair, Insulation of existing GI duct in different places by using insulation as specified by manufacture for Central AC plants (AC Plant Make - Blue star) 75 TR capacity complete all as specified and directed
Suppy and Fixing in repair, MS cable tray of 300mm width complete all as specified and directed .
Suppy and Fixing in repair, HEPA Filter for Central AC plants (AC Plant Make - Blue star) 75 TR of existing size and capacity complete all as specified and directed.
Suppy and Fixing, in repair, 22G PGI sheet Ducting for HEPA filter chamber for Central AC plants 75 TR capacity complete all as specified and directed
Suppy and Fixing in repair, Canvass for Plenum connection for Central AC plants (AC Plant Make - Blue star) 75 TR capacity complete all as specified and directed
Suppy and Fixing in repair, 25 mm Foil Faced Glass Wool Insulation for plenum for Central AC plants (AC Plant Make - Blue star) 75 TR capacity complete all as specified and directed
Materials and Labour for preparation of old painted external steel surface of MS water pipe of 250 mm dia in Central AC plant, cleaned off all rust by brushing with wire brushes and applying two coats of synthetic enamel paint (Spray painting) over a coat of red oxide primer complele all as specified and directed .
Materials and Labour for preparation of old painted external steel surface of MS water pipe of 100 mm dia in Central AC plant, cleaned off all rust by brushing with wire brushes and applying two coats of synthetic enamel paint (Spray painting) over a coat of red oxide primer complele all as specified and directed .
Materials and Labour for preparation of old painted external steel surface of MS water pipe of 80 mm dia in Central AC plant, cleaned off all rust by brushing with wire brushes and applying two coats of synthetic enamel paint (Spray painting) over a coat of red oxide primer complele all as specified and directed .
Materials and Labour for preparation of old painted surface of external part of FRP cooling tower of Central AC plant, cleaned off all rust by brushing with wire brushes and applying two coats of synthetic enamel paint (Spray painting) over a coat of primer as recomended by manufacturer complele all as specified and directed .
Disconnecting electrically and dismantling of unserviceable two body mortuary cooling chamber of 3 TR capacity, single phase, machine (Model No RT 46 of Make : Blue star), servicing of evaporator coil & Condensing coil of mortuary cooling chamber, cleaning of cooling coil with blower fan, washing with chemicals, cleaning of fins, copper tubes, pipes blower motor and other connected accessories and taking out and replacement of unserviceable/defective spares/parts with new ones and re-assembling, refixing two body mortuary cooling chamber in position duly repaired, jointing of refrigerant pipe lines filling of refrigerant gas and testing complete all as directed. Note - New spare/parts shall be measured and paid separately under relevant items as "supply only".
Supply only starting capacitor suitable for single phase, 40MFD, 220 volts, 50 Hz for mortuary cooling chamber all as described here in before as per existing complete all as specified and directed.
Supply only Running capacitor suitable for single phase, 40MFD, 220 volts, 50 Hz for mortuary cooling chamber for mortuary cooling chamber all as described here in before as per existing complete all as specified and directed.
Supply only Starting relay suitable for single phase, 220 volts, 50 Hz for mortuary cooling chamber as described here in before as per existing complete all as specified and directed.
Supply only over load protector suitable for single phase, 220 volts, 50 Hz, for mortuary cooling chamber all as described here in before as per existing complete all as specified and directed.
Supply only Blower fan motor of mortuary cooling chamber, single phase, AC 220 Volts, 50 Hz for mortuary cooling chamber all as described here in before as per existing complete all as specified and directed.
Dismantling of sealed compressor unit (.Make : Kirloskar) after removing refrigerant pipe connection, electric wire connection etc from two body mortuary cooling chamber and Supply and Fixing 3 TR sealed unit compressor for machine Model RT-46, 230 Volts AC, single phase, 50 Hz, 8.5 Amps including vaccum and charging of refrigerant gas R-22, leakage test, and testing of the same complete all as specified and directed.
Materials and Labour for leakage testing with nitrogen gas pressure 24 to 48 hours, checking of copper pipe lines, cooling coil, suction/discharge gas pipe lines and repair of the same with gas welding, replacement of defective nuts/washers with new ones for mortuary cooling chamber as required at site complete all as specified and directed .
Materials and Labour for servicing, greasing and varnishing of blower fan motor of mortuary cooling chamber, AC 220 Volts, 50 Hz. complete all as directed.
Dismantling of sealed compressor unit (Make: Kirloskar) carefully after removing refrigerant pipe connection, electric wire connection etc from outdoor unit of Walk in cooler and Supply and Fixing sealed unit compressor , capacity 3 TR, 3 phase , 415 Volts , including vaccum and charging of refrigerent gas, leakage test and testing of the same complete all as specified and directed .
Materials and Labour for leakage test with nitrogen gas pressure 24 to 48 hours, checking of copper pipe lines, cooling coil, suction/discharge gas pipe lines for leakage of walk- in- cooler and repair of the same with gas welding, replacement of defective nuts/washers with new ones complete all as specified and directed.
Supply and Fixing high speed blower fan motor of walk -in -cooler (Make of walk -in -cooler - Kirloskar) for outdoor unit, AC 415 Volts, 50 Hz as per existing model and RPM, fixing in position including electrical connections complete all as specified and directed.
Materials and Labour for cleaning, servicing of complete outdoor unit evaporator coil of walk -in -cooler (Make of walk -in -cooler - Kirloskar), 3 TR Capacity, cleaning of cooling coil with blower fan, washing with chemicals, cleaning of fins, copper tubes, pipes, blower motors and other connected accessories complete all as specified and directed.
Materials and Labour for cleaning, servicing of complete indoor unit, cleaning of cooling coil with blower fan, cleaning of Walk- in -cooler (Make of walk -in -cooler - Kirloskar), washing with chemicals, cleaning of fins, copper tubes, pipes, blower motors and other connected accessores complete all as specified and directed.
Supply and Fixing high speed blower fan motor of walk in cooler for indoor unit, AC 220 Volts, 50 Hz as per existing model and RPM, fixing in position including electrical connections complete all as specified and directed.
Materials and Labour for cleaning, servicing of complete outdoor unit evaporator coil of walk in cooler 10000 Btu/hrs Capacity, (Make of walk -in -cooler - Kirloskar), cleaning of cooling coil with blower fan, washing with chemicals, cleaning of fins, copper tubes, pipes, blower motors and other connected accessories complete all as specified and directed.
Materials and Labour for cleaning, servicing of complete indoor unit, cleaning of cooling coil with blower fan, cleaning of Walk- in- cooler of capacity 10000 Btu/hrs, washing with chemicals, cleaning of fins, copper tubes, pipes, blower motors and other connected accessores complete all as specified and directed.
Materials and Labour for Leakage testing, nytrogen flushing, vacumising and gas charging of 10000 Btu/hrs Walk-in-cooler of Make Blue Star make complete all as required and directed.
Suppy and Fixing in repair, controller and display set for Walk -in - cooler of capacity 10000 Btu/hrs of existing make & model complete all as specified and directed.
Suppy and Fixing in repair, Power contractor, 100 Amps, 3 Pole, AC, 220 Volts complete all as specified and directed.
Suppy and Fixing in repair, Power contractor, 50 Amps, 3 Pole, AC, 220 Volts complete all as specified and directed.
Suppy and Fixing in repair, Power contractor, 40 Amps, 3 Pole, AC, 220 Volts complete all as specified and directed.
Suppy and Fixing in repair, Power contractor, 32Amps, 3 Pole, AC, 220 Volts complete all as specified and directed.
Suppy and Fixing in repair, Power contractor 25 Amps, 3 Pole AC, 220 Volts complete all as specified and directed.
Suppy and Fixing in repair, Additional instantaneous auxillary contact blocks for power contractor, 3 Pole AC, 220 Volts, complete all as specified and directed.
Suppy and Fixing in repair, Over load rleay, 12 to 18 Amps complete all as specified and directed.
Suppy and Fixing in repair, Over load rleay, 5.5 to 8 Amps complete all as specified and directed.
Suppy and Fixing in repair, MCCB, 100 Amps, 4 pole, breaking capacity 36 KA complete all as specified and directed.
Suppy and Fixing in repair, MCCB, 250 Amps, 4 pole, breaking capacity 36 KA complete all as specified and directed.
Suppy and Fixing in repair, MCCB, 160 Amps, 4 pole, breaking capacity 25 KA complete all as specified and directed.
Suppy and Fixing in repair, MCB, SP, 6 Amps rating, " B" curve complete all as specified and directed.
Suppy and Fixing in repair, MCB, SPN , 32 Amps rating, " B" curve complete all as specified and directed.
SAI CONSTRUCTION
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .