| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 31 1 6 SEBADAL ROAD UDAYPUR NIMTA KOLKATA 49 | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹5.2 L+₹20,206 (4.02%)Rejected-Finance 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | L2 | Rejected-Finance quoting higher rate | |
| 3 | L3₹5.3 L+₹22,576 (4.49%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance quoting higher rate | |
| 4 | Rejected-Technical 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | - | Rejected-Technical as per the technical evaluation sheet | |
| 5 | Rejected-Technical BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | - | Rejected-Technical as per the technical evaluation sheet |
| Sl No | Description | Qty | Unit | FAME ENGINEERING L1 | M/s Singh Electrical Works L3 | BENGAL TRADING CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of casette Air-conditioner machine having Rated/Standard cooling capacity(at 100% load) not less than 8790W, rated ISSER range- 3.46 to 4.5, Noise level not more than 45db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube etc. (Mitsibushi Electric PL-M30BAKDA,PU-M30VAK-DA,PLP-6BA/Mitsubishi Heavy Industries/O General as per approved by EIC). | 2 | No. | 1,14,000 ₹2,28,000 | 1,20,000 ₹2,40,000 | 1,12,000 ₹2,24,000 Lowest |
| 2.00 | Supply & delivery of Inverter type split Air-conditioner machine having Rated cooling capacity(at 100%load) not less than 7000W, rated ISSER range- 4.00 to 5.22, Noise level not more than 51db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (Make:- O-General ASGG 24CPTB-B(R-32)/Mitsubishi Heavy Industries SRK24YYM-W6/Mitsubishi Electric RJS22VF as per approved by EIC). | 2 | No. | 71,755 ₹1,43,510 | 70,000 ₹1,40,000 Lowest | 74,000 ₹1,48,000 |
| 3.00 | Supply & delivery of Inverter type split Air-conditioner machine having Rated cooling capacity(at 100%load) not less than 5200W, rated ISSER range- 3.83 to 5.00, Noise level not more than 50db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (O-General ASGG18CPTB-B(R32)/Daikin//Mitsubishi Heavy Industries SRK 18YXP-W6/Mitsubishi Electric RJS 18VF as per approved by EIC). | 1 | No. | 61,000 ₹61,000 Lowest | 61,500 ₹61,500 | 61,500 ₹61,500 |
| 4.00 | Installation, testing & commissioning of the above-said split ACs on wall including fixing with necessary tools, tackles & mending good the damages as per direction of E.I.C. | 5 | item | 2,000 ₹10,000 | 2,400 ₹12,000 | 1,900 ₹9,500 Lowest |
| 5.00SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required. | ||||||
| 5.01 | a) 5/8" (15.88 mm.) (for suction) & 1/4" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standardBS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC) | 30 | Mtrs | 900 ₹27,000 | 800 ₹24,000 Lowest | 1,000 ₹30,000 |
| 5.02 | (a) 5/8'(15.88 mm) (for suction) & 3/8" (9.52mm) (for discharge) (As per standard 85864 or ANSIB 16.22) mm incl. 19 mm thick insulation. | 30 | Mtrs | 1,100 ₹33,000 | 1,000 ₹30,000 Lowest | 1,100 ₹33,000 |
| 6.00 | Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Cable as approved by E.I.C) | 60 | Mtr | 90 ₹5,400 Lowest | 120 ₹7,200 | 100 ₹6,000 |
| 7.00 | Supply & Laying of 3 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Cable as approved by E.I.C) | 30 | Mtr | 92 ₹2,760 Lowest | 95 ₹2,850 | 95 ₹2,850 |
| 8.00 | Supply & Laying of 3 core 4sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/ Havells /RR Cable as approved by E.I.C) | 30 | Mtr | 125 ₹3,750 Lowest | 140 ₹4,200 | 135 ₹4,050 |
Tender Value
Refer Docs
EMD Value
₹10,073
Closing Date
16 Feb 2026, 1:00 pmClosed
The Executive Engineer PWD,ECD
O/O The Executive Engineer PWD Electrical Construction Division New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Renovation of EI Works and SITC of AC Machines in respect of reorientation of Room no.721 to 727 at the 7th Floor of New Office Complex Building, Alipore, Kolkata 700027 for accommodation of Architect and other staffs under Chief Engineer South Zon
2025_WBPWD_919016_3
WBPWD/EE-ECD/e-NIQ-34/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Alipore
please refer tender documents
5 documents required · 5 mandatory
₹10,073
O/O The Executive Engineer PWD ECD
26 May 2026
28 Jan 2026
18 Feb 2026
28 Jan 2026
16 Feb 2026
7 Feb 2026
28 Jan 2026 - 5 Feb 2026
5 Feb 2026
Supply & delivery of casette Air-conditioner machine having Rated/Standard cooling capacity(at 100% load) not less than 8790W, rated ISSER range- 3.46 to 4.5, Noise level not more than 45db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube etc. (Mitsibushi Electric PL-M30BAKDA,PU-M30VAK-DA,PLP-6BA/Mitsubishi Heavy Industries/O General as per approved by EIC).
Supply & delivery of Inverter type split Air-conditioner machine having Rated cooling capacity(at 100%load) not less than 7000W, rated ISSER range- 4.00 to 5.22, Noise level not more than 51db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (Make:- O-General ASGG 24CPTB-B(R-32)/Mitsubishi Heavy Industries SRK24YYM-W6/Mitsubishi Electric RJS22VF as per approved by EIC).
Supply & delivery of Inverter type split Air-conditioner machine having Rated cooling capacity(at 100%load) not less than 5200W, rated ISSER range- 3.83 to 5.00, Noise level not more than 50db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (O-General ASGG18CPTB-B(R32)/Daikin//Mitsubishi Heavy Industries SRK 18YXP-W6/Mitsubishi Electric RJS 18VF as per approved by EIC).
Installation, testing & commissioning of the above-said split ACs on wall including fixing with necessary tools, tackles & mending good the damages as per direction of E.I.C.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required.
a) 5/8" (15.88 mm.) (for suction) & 1/4" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standardBS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
(a) 5/8'(15.88 mm) (for suction) & 3/8" (9.52mm) (for discharge) (As per standard 85864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Cable as approved by E.I.C)
Supply & Laying of 3 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Cable as approved by E.I.C)
Supply & Laying of 3 core 4sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/ Havells /RR Cable as approved by E.I.C)
Supply and laying 25mm PVC pipe (heavy type) for water drainage.(25mmOD, 1mm thick) with proper support & bracket as per direction. (Make- Supreme/Oriplast).
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.23 MB
Tendernotice_2.pdf
PDF • 0.51 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2434106.xls
BOQ • 0.32 MB
eniq34.pdf
Tender Documents • 1.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .