Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.2 L+₹2.1 L (6.80%)Rejected-Finance | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹32.3 L+₹2.2 L (7.20%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹35.5 L+₹5.4 L (17.8%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹36.4 L+₹6.2 L (20.5%)Rejected-Finance | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 May 2023, 6:00 pmClosed
Sh Saurabh Gupta, EE
GE(W) Colaba, Mumbai
REPAIR/REPLACEMENT OF PVC OVERHEAD TANKS, GI TUBING ALONGWITH FITTINGS AND FIXTURES CLEANING OF OVERHEAD TANKS ETC AND RELATED B/R WORKS UNDER AGE B/R CENTRAL UNDER GE (W) COLABA, MUMBAI
2023_MES_592111_1
8728/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(W) Colaba, Mumbai
₹90,000
Yes
12 Jul 2023
28 Apr 2023
18 May 2023
28 Apr 2023
16 May 2023
10 May 2023
Amount
Taking up or down 15 mm bore steel tubing and connection including cleaning for refixing or removal to store all as specified and directed
Taking up or down 20 mm bore steel tubing and connection including cleaning for refixing or removal to storeall as specified and directed
Taking up or down 25 or 32 mm bore steel tubing and connection including cleaning for refixing or removal to store foall as specified and directed
Taking up or down 40 or 50 mm bore steel tubing and connection including cleaning for refixing or removal to store all as specified and directed
S&F UPVC pipes out side dia 15 mm of pressure rating 10 Kgf/Sqcm, fixed to walls, ceilings or in floors including all fittings and fixtures all as specified and directed
S&F UPVC pipes out side dia 20 mm of pressure rating 10 Kgf/Sqcm, fixed to walls, ceilings or in floors including all fittings and fixtures all as specified and directed
S&F UPVC pipes out side dia 25 mm of pressure rating 10 Kgf/Sqcm, fixed to walls, ceilings or in floors including all fittings and fixtures all as specified and directed
S&F 15 mm bore GI pipes medium grade galvanized with all fittings and fixtures fixed to walls and ceilings or laid in floor all as specified and directed
S&F 20 mm bore GI pipes medium grade galvanized with all fittings and fixtures fixed to walls and ceilings or laid in floor all as specified and directed
S&F 25 mm bore GI pipes medium grade galvanized with all fittings and fixtures fixed to walls and ceilings or laid in floor all as specified and directed
S&F 40 mm bore GI pipes medium grade galvanized with all fittings and fixtures fixed to walls and ceilings or laid in floor all as specified and directed
S&F 50 mm bore GI pipes medium grade galvanized with all fittings and fixtures fixed to walls and ceilings or laid in floor all as specified and directed
Refixing old 15 mm bore steel tubing and connection in new or old position (walls ceiling, floors etc) all as specified and directed
Refixing old 20 mm bore steel tubing and connection in new or old position (walls ceiling, floors etc) all as specified and directed
Refixing old 25 mm bore steel tubing and connection in new or old position (walls ceiling, floors etc) all as specified and directed
S&F in repairs 15 mm bore in existing or new GI pipe ÏSI Marked Embosed "fittings like union joint, socket reducer all as specified and directed.
S&F in repairs 20 mm bore in existing or new GI pipe ÏSI Marked Embosed "fittings like union joint, socket reducer all as specified and directed.
S&F in repairs 25 mm bore in existing or new GI pipe ÏSI Marked Embosed "fittings like union joint, socket reducer all as specified and directed.
S&F in repairs 40 mm bore in existing or new GI pipe ÏSI Marked Embosed "fittings like union joint, socket reducer all as specified and directed.
S&F in repairs 50 mm bore in existing or new GI pipe ÏSI Marked Embosed fittings like union joint, socket reducer all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 50 mm bore pipe all as Specified and directed. Make : SIR/ Zolet/ globe , sample as approved by GE
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 40 mm bore pipe all as Specified and directed. Make : SIR/ Zolet/ globe , sample as approved by GE
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 25 mm bore pipe all as Specified and directed. Make : SIR/ Zolet/ globe , sample as approved by GE
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore pipe all as Specified and directed. Make : SIR/ Zolet/ globe , sample as approved by GE
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 15 mm bore pipe all as Specified and directed. Make : SIR/ Zolet/ globe , sample as approved by GE
S&F in repair Chromium plated brass angle valve for 15mm bore pipe, fixed in repairs all as Specified and directed. Make : Cera/ Prayag/ Jaguar , sample as approved by GE
S&F in repair, two way angle valve cock chromium plated brass fancy type bore 15mm all as Specified and directed. Make : Cera/ Prayag/ Jaguar sample as approved by GE
S&F in repairs PVC connection 15mm dia and 45cm long with 2 Nos PTMT nuts all as specified and directed. Make : Cera/ Prayag/ Jaguar sample as approved by GE
Demolition and breaking up drain pipes (SGSW, AC or RCC, CI ) of internal dia 75/110 mm, set in cement mortar all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 110mm bore all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 75 mm bore all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore all as specified and directed.
S&F PVC (SWR) bends any radius, 75 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single Y) equal or unequal radius, 110 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single Y) equal or unequal radius, 75 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single T) equal or unequal radius, 110 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single T) equal or unequal radius, 75 mm bore all as specified and directed.
S&F PVC (SWR) reducers, 110 mm bore all as specified and directed.
S&F PVC (SWR) reducers, 75 mm bore all as specified and directed.
S&F PVC (SWR) vent cowl, 110 mm bore all as specified and directed.
S&F PVC (SWR) "P" trap, 110 mm bore all as specified and directed.
S&F PVC (SWR) "P" trap, 75 mm bore all as specified and directed.
S&F PVC (SWR) "Q" trap, 110 mm bore all as specified and directed.
S&F PVC (SWR) "Q" trap, 75 mm bore all as specified and directed.
Dismantling water storage tank exc 250 & n’ exc 500 litres capacity all as specified and directed.
Dismantling water storage tank exc 500 & n’ exc 1000 litres capacity all as specified and directed.
Dismantling water storage tank exc 1000 & n’ exc 2000 litres capacity all as specified
Dismantling water storage tank exc 2000 & n’ exc 4000 litres capacity all as specified and directed.
S&F 500 litres capacity rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple all as specified in SSR part I and directed.
S&F 1000 litres capacity rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple all as specified in SSR part I and directed.
S&F for 2000 litres capacity rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part I and directed.
S&F for 4000 litres capacity rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part I and directed.
S&F in repairs Ball Valves 15 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) all as specified and directed.
S&F in repairs Ball Valves 25 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) all as specified and directed.
S&F in repairs Ball Valves 40 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) all as specified and directed.
Demolition of re-inforced cement concrete (re-inforce cut as required to facilotate demolition) in any position ( Beam, landing Chajja and Roof slab etc ) ground floor/ other than ground floor, projection of balcony all as specified and directed.
S&F 300 litres capacity white loft polyethene water storage tanks hoisted and fixed in position including tank nipple etc and 15mm dia ball valves of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball all as Specified and directed. Make : Sintax/ tuff/ Plasto sample as approved by GE
S&F in repairs framed work rolled sections sections conforming to Gde Fe-290(Gde-165-E) as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc, fastening and making good dismentaled prtion in cement mortar (1:3) including oil bound distemper complete all as specified and directed.
M&L for cutting holes in brick wall built in cement mortar for inserting angle and making good dismentaled prtion in cement concrete 1:2:4 type B-1 all as specified and directed.
M&L for preparation of new untreated steel surface of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facing dressed stone work and precast concrete articles including removing debris out side MD land all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean raddius built in CM 1:6 all as specified and directed.
Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land all as specified and directed. Note : Height of Bldg Up to fourth floor.
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land complete all as specified and directed. Note : Height of Bldg above five Up to Eight floor.
M&L 15-20 mm thick ready mix plaster in multy layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished surfaces even and fair, including use of scaffolding, for height of bldgs upto Four stories all as specified and directed. Name of Manufacturer: M/s Dr Fixit /ACC/ M/s Ultratech Cement Ltd/ M/s Sound buildcare pvt. Ltd/ or other approved equivalent make..
M&L 15-20 mm thick ready mix plaster in multy layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished surfaces even and fair, including use of scaffolding, for Height of Bldg above five Up to Eight floor all as specified and directed. Name of Manufacturer: M/s Dr Fixit /ACC/ M/s Ultratech Cement Ltd/ M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
Supply only liquid water proofing compound
Firstly old loose spelled concrete should be chiseled from roof ceiling with the help of scrapers, chisel & hammer after that cleaning of rust from mild steel rod and applying cement sprey 3.00 Kg per sqm by paint brush over cleaned surfaces and Material and Labour for 20-30 mm thick ready mix plaster in Multi layer for ceiling on fair faces of brick wall or concrete surfaces, finished surfaces even and fair Including three coat white wash all as specified and directed.
M&L 12 mm thick Ready Mix Plaster in single layer of make / brand - ACC's Accoplast / CK Birla's Aerocon / Speed Dry Mix's Ecoplaster / Magic Plast / Build well, on other than fair faces of concrete surfaces in wall ( internal surface ) and finished surfaces even and smooth without using extra cement all as specified and directed. Name of Manufacturer: M/s Dr Fixit /ACC/ M/s Ultratech Cement Ltd/ M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant primer coat through authorised applicators of paint manufacturers only of approved shade all as specified and directed. Make: "Tractor Uno" of Asian Paints / "Jadoo"of Berger Paints / Nerolac Beauty of Nerolac paints as approved by GE all as specifeid .
M&L for preparing newly plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings from Ground floor upto 04 storeys height of bldgs all as specified and directed. Make: "Apex Ulitima" of Asian Paints "trucare" Primer / "Weather coat all Guard"of Berger Paints / Dulux weather shield Max of Dulux Paints/Excel top Guard of Nerolac paints as approved by GE complete all as specifeid .
M&L for preparing newly plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings from 5th floor upto 08th storeys height of bldgs all as specified and directed. Make: "Apex Ulitima" of Asian Paints "trucare" Primer / "Weather coat all Guard"of Berger Paints / Dulux weather shield Max of Dulux Paints/Excel top Guard of Nerolac paints as approved by GE complete all as specifeid .
Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish complete all as specified and directed.
M&L for first and premium quality of non skid, ceramic digital “coloured” matt finish joint less tiles of size 300 x 300 x 6-7mm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 all as specifed and directed. Make : Johnson tiles / Kajaria / Orient Bell, Sample as approved By GE.
M&L for first and premium quality of Glazed ceramic coloured digital tiles 600 mm x 300 mm or 405 mm x 250 mm x 6 mm to 7 mm thick, in skirting, dados, risers to steps, etc set and jointed in neat cement slurry, and pointed in coloured cement to match the shades of the tiles laid over and including 10mm thick rendering or backing coat in cement mortar 1:4 all as specified and directed. Make : Johnson tiles / Kajaria / Orient Bell, Sample as approved By GE.
M&L for glazed ceramic exterior wall tiles 6 to 8 mm thick etc set & jointed in cement and pointed in coloured cement to match the shade of tile laid over and including 10mm thick rendering or backing coat in cement mortar 1:4 all as specified & directed. Make – Johnson (Endura) or equivalent in Kajaria/ Euro tiles, sample as approved by GE
M&L for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using Epoxy Mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, PU solvent membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying PU solvent of approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications. Supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, PU solvent membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 5 mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying PU solvent of approved equivalent in two coats at 1.5 kg per Sqm to achieve total dry film thickness of 850 to 1000 microns etc, complete as per Manufacturer specifications over and including padding of ready mixed micro cement concrete Type B1, 1:2:4 , 35 mm average thick concrete on RCC roof surfaces and all other similar works complete all as specified and directed Make: Dr fixit flexi PU / Asian
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges all as specified and directed
M&L multi-rib TM profile high tensile 550 MPA yield strength colour coated galvalume corrugated steel sheet having maximum pitch of 250mm, c/c and minimum 30mm crest depth in length as per site requirement. The feed material is to be manufactured out of 0.50mm (TCT). Total coated thickness with 18-20 microns top coat over 5 microns primer and 8-10mm alkyd backer, zinc aluminium alloy of AZ-150. The sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium (55%)and silicon (1.5%) with toal mass coating of 150 gms/sqm on both sides. Covered width will be 1020mm and sheet length as per site requirement. The profile is having return leg for proper side lap. The sheet shall be fixed using self drilling/self capping screws with EDPM seal or fixed with 'L' or 'J' type or cranked hook bolts in roof,complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying two coats of smart care damp proof Elastomeric and resilient acrylic polymers and reinforcing synthetic fibers water proofing coating Make : Asian Paints smart care damp proof or equivalent ) through authorized applicator only including use of scaffoldings all as specified and directed. Make and colour as approved by GE complete all as specified and directed. Note : Up to fourth floor.
All as per item No. 80 above but 5th to 8th floor all as specified and directed. Note : from fifth floor and above
K.C.P ENTERPRISES
Unitech Enterprises
SHREE JAGDISH FURNITURE CO.
N.S.ENTERPRISES
SAHU AND SAHU CO.
SHRI SAI ENTERPRISES
Bidder Name
Unitech Enterprises
HINDUSTAN BUILDERS
K.C.P ENTERPRISES
SAHU AND SAHU CO.
SHRI SAI ENTERPRISES
SHREE JAGDISH FURNITURE CO.
N.S.ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .