Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.1 CrAccepted-AOC | ₹4.1 Cr | 1 | Accepted-AOC Being L1 bidder |
| 2 | 2₹5.9 Cr+₹1.8 Cr (43.5%)Rejected-Finance SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | ₹5.9 Cr+₹1.8 Cr (43.5%) | 2 | Rejected-Finance Not being L1 bidder |
| 3 | 3₹6.0 Cr+₹1.8 Cr (44.7%)Rejected-AOC CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹6.0 Cr+₹1.8 Cr (44.7%) | 3 | Rejected-AOC Not being L1 bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not admitted since not fulfil the NIT eligibility criteria |
Tender Value
₹4 Cr
EMD Value
₹4.8 L
Closing Date
19 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF GROUND EXPLOITATION SYSTEM OF AEW AND C AT AF STN BORJHAR
2022_MES_524020_1
88438/E8
Open Tender
Civil Works
Lump-sum
365 days
BORJHAR
As per tender documents
7 documents required · 7 mandatory
₹2,000
GE (AF) BORJHAR
₹4.8 L
Yes
28 Aug 2022
13 May 2022
21 Jul 2022
13 May 2022
19 Jul 2022
13 Jun 2022
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (CONCRETE MAST AND ELEVATED CABLE DUCT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (ROAD/PATH AND CULVERT) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (COMPOUND WALL/ FENCING AND GATE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- X EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XII (UPS AND CONDUIT PIPES) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIII (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIV (AIR CONDITIONING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES.
SITE CLEARANCE Bringing approved Earth from outside mod land and forming embankment including raising (or lowering ) earth,spreding in layers n exc 30 cm thick watering ,ramming/rolling and finishing to required size and shape etc n exc 1.50 m high from base complete all as specified and directed. Note:- (i) Payment shall be made for soild quantity arrived after consolidation. (ii) Before execution of this item use of earth shall be tested/ checked for suitability of use and rate of tesing shall be included in quoted rates.
ROAD/ PATH/ CULVERT M & L for preparation of new plastered surface of wall/ roof/ floor by rubbing down/ scraping and three coat of exterior grade emulsion paint (weather coat) in camoflauge pattern on wall, roof or floor in any surface over one coat of weather primer as specified and complete all as specified. Note:- Weather proof acrylic floor paint to be used for painting in floor/ hard standing.
Material and labour for Pavement Quality concrete (PQC) (Design mix) of minimum field flexural strength 45 Kg / Sqcm (Lower Control Limit) LCL after 28 days in pavement slab using minimum 400 Kg of cement per cum with crushed stone aggregate of greading as specified including necessary form work and using non circular synthetic fibre reinforcement @ 0.25% of weight of cement of PQC, laid in panels, spread and compacted using mechanical paver, mechanically vibrated and bull nosing / rounding off edges, curing, brooming, belting etc complete all as specified and as directed. (Thickness of concrete shall be 150mm ). Note :- (a) All type of joints shall be measured and paid separately under respective items of BOQ. (b) No deduction shall be made from concrete for space occupied by construction and dummy joint However, deduction shall be made for the space occupied by expansion joints. (c) The non circular fibre synthetic reinforcement mixed with concrete shall be measured and paid separately as ‘Supply only’ under respective item of BOQ. (d) Cost of any admixtures required to achieve the desired properties of concrete shall be deemed to be included in the unit rate quoted for PQC nothing extra shall be paid on this account. (e) No price adjustment shall be applicable if excess quantity of cement content used in the work as approved in the Design Mix exceed 400 Kg. Minimum cement content shall be used 400 Kg per Cum.
SEWAGE DISPOSAL M & L for on site LLDPE septic tank OF CAPACITY 5500 ltr to 6000 ltr with necessary strong basement with concrete as per manufacturer's instruction complete all as specified and as directed. Note:- (i) Cost of basement shall be deemed to be included in quoted rates. (ii) Cost of excavation and earth work shall be deemed to be included in quoted rates.
BLANK
M & L for soak well excavation in any tye of soil founadtion in PCC 1:3:6 wall of honey combed with topping of M-25 concrete, including interce pting chamber made up of Brick work in CM RCC cover slab in M-25/SFRC cover inter connecting pipe of RCC/DWC complete with rick bats of suitable size for 1.80 x 1.50 M deep efective depth completed all as specified.
M & L for soak well excavation in any tye of soil founadtion in PCC 1:3:6 wall of honey combed with topping of M-25 concrete, including interce pting chamber made up of Brick work in CM RCC cover slab in M-25/SFRC cover inter connecting pipe of RCC/DWC complete with rick bats of suitable size for 1.80 x 3.00 M deep efective depth completed all as specified.
COMPOUND WALL/ FENCING AND GATE S & F CONSEC-ZAL Super Rozar punched barb tape (SRPBT) Aluminium base helix coil with and including necessary GI fixing clips for securing complete all as specified and directed with follwing specifications: -(i) Dia of coil (when unstretched)- 610mm (ii) No of circles-51 turns per coil (iii) Weight of each coil with hessian pack-8.50 kg(+0.5) (iv) Coverage per coil-8RM (v) Central core wire- made from 2.50mm dia GI-H T S S wire as per IS-4454 galvanised as per IS-2629 (vi) Razor punched Strip Razor puched tape is CONSEC -ZAL Steel comprising of Aluminum base with Zinc coating @ 150gm/ Sqm conforming to ASTM A-792/A-792M with additional primer treatment of Epoxy/ Polyurethene & Final paint top coat of Caulified green shade (BSL 139) by Hot Dipping procress Note: Running length of the wall shall be measured for payment purpose)
EXTERNAL ELECTRIC SUPPLY M&L for PCC cable route marking of 150x50x600 mm for under ground cable complete all as per specified and directed.
Supplying, installation, commissioning and testing LT panel board 3 phase 4 wire system outdoor type factory made, supported with MS angle iron frame of size 50x50x6mm, dust and vermin proof cubical type interlocking arrangement (IP- 55 protection) fabricated with 3.15 mm CRCA sheet with Anti corrosion coating & finally polyester powder coated of finite green fully compartment with providing with suitable size of coated copper busbar strip complete all as specified for the following (Main Panel):- (a) Incoming (i) MCCB 63-160 AMPS 4 pole, 415 Vollts, 36 KA with microprocessor release with adjustable overload setting from 0.4 to 1.0 x In - (Model No DN2-250D) - 01 No. (b) Outgoing (i) MCCB 100-125 AMPS 4 pole, 415 Vollts, 25 KA with thermal magnetic release with adjustable overload setting from 0.8 to 1.0 x In - (Model No DN1-250C) - 01 No. (ii) MCCB 63-80 AMPS 4 pole, 415 Vollts, 25 KA with thermal magnetic release with adjustable overload setting from 0.8 to 1.0 x In - (Model No DN0-100C) - 01 No. (iii) MCB SPN 32 Amps - 02 (iv) Digital type Amp meter (3 PH) with CT 0-400 Amps - 01 Nos (v) Digital type voltmeter 3 ph 0-500 Volts -01 No. (vi) Indicating lamps (RYB) 01 set of 3. (vii) Insulated Copper bus bar rating 350 Amps 3 phase neutral-01 set (viii) Cabble Alley for incoming & outgoing cable. (ix) One spare space for fixing of MCCB
Supplying, installation, commissioning and testing LT panel board 3 phase 4 wire system outdoor type factory made, supported with MS angle iron frame of size 50x50x6mm, dust and vermin proof cubical type interlocking arrangement (IP- 55 protection) fabricated with 3.15 mm CRCA sheet with Anti corrosion coating & finally polyester powder coated of finite green fully compartment with providing with suitable size of coated copper busbar strip complete all as specified for the following (Main Panel):- (a) Incoming (i) MCCB 63-160 AMPS 4 pole, 415 Vollts, 36 KA with microprocessor release with adjustable overload setting from 0.4 to 1.0 x In - (Model No DN2-250D) - 01 No. (b) Outgoing (i) MCCB 63-80 AMPS 4 pole, 415 Vollts, 25 KA with thermal magnetic release with adjustable overload setting from 0.8 to 1.0 x In - (Model No DN0-100C) - 01 No. (ii) MCCB 32-40 AMPS 4 pole, 415 Vollts, 25 KA with thermal magnetic release with adjustable overload setting from 0.8 to 1.0 x In - (Model No DN0-100C) - 02 No. (iii) On load change over switch suitable for 415 Volts of capacity 100 Amps - 01 (iv) Digital type Amp meter (3 PH) with CT 0-400 Amps - 01 Nos (v) Digital type voltmeter 3ph 0-500 Volts -01 No. (vi) Indicating lamps (RYB) 01 set of 3. (vii) Insulated Copper bus bar rating 200 Amps 3 phase neutral-01 set (viii) Timer with contractor (ix) Cable Alley for incoming & outgoing cable. (x) One spare space for fixing of MCCB
Supplying, installation, commissioning and testing LT panel board 3 phase 4 wire system outdoor type factory made, supported with MS angle iron frame of size 50x50x6mm, dust and vermin proof cubical type interlocking arrangement (IP- 55 protection) fabricated with 3.15 mm CRCA sheet with Anti corrosion coating & finally polyester powder coated of finite green fully compartment with providing with suitable size of coated copper busbar strip complete all as specified for the following (Main Panel):- (a) Incoming (i) MCCB 63-160 AMPS 4 pole, 415 Vollts, 36 KA with microprocessor release with adjustable overload setting from 0.4 to 1.0 x In - (Model No DN2-250D) - 01 No. (b) Outgoing (i) MCCB 63-80 AMPS 4 pole, 415 Vollts, 25 KA with thermal magnetic release with adjustable overload setting from 0.8 to 1.0 x In - (Model No DN0-100C) - 02 No. (ii) MCCB 32-40 AMPS 4 pole, 415 Vollts, 25 KA with thermal magnetic release with adjustable overload setting from 0.8 to 1.0 x In - (Model No DN0-100C) - 01 No. (iii) Digital type Amp meter (3 PH) with CT 0-400 Amps - 01 Nos (iv) Digital type voltmeter 3 ph 0-500 Volts -01 No. (v) Indicating lamps (RYB) 01 set of 3. (vi) Insulated Copper bus bar rating 200 Amps 3 phase neutral-01 set (vii) Cabble Alley for incoming & outgoing cable. (viii) One spare space for fixing of MCCB
M & L for chemical earthing complete with copper earth plate 90x60x5 mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of copper strip 50x6 mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 all as directed.
S&F isolation transformer of capacity 100 KVA, three phase, 50 Hzs copper wound, oil cooled, class of insulation A, metallic body powder coated designed for input voltage range 415 + 5% and output voltage range 415 + 5%, ratio 1:1, vector group : Dyn 11, efficiency more than 95% complete all as specified and directed by Engr in Charge.
Supply and installed automatic power factor correction (APFC) Panel for 3 Phase, 415 Volt & 50 Hzs system of capacity 50 KVAR with MD-XL capacitor with 8 steps (3x10, 3x5, 2x2.5) complete all as specified and directed by Engr in Charge.
S&F GI pipe heavy grade pole of hight 2.5 mtr long and dia 80 mm bore suitable for mounting street including base plate and nuts bolts and foundation complete all as specified and directed by Engr in charge.
S&F Hot moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amps 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and directed by Engr in charge.
S&F street light bracket made out by 40 mm dia GI pipe light grade of length 1.5 mtr long complete fixed over pole/GI pipe complete all as specified and directed by Engr in charge.
S&F street light fitting LED 36 watt pressure die cast aluminium housing with heat resistance toughened glass and IP 66 protection luminaries complete all as specified and directed by Engr in charge.
S&F LED flood light fitting of 70 watt pressure die cast aluminium housing with heat resistance toughened glass and IP 66 protection luminaries complete all as specified and directed by Engr in charge.
S&F post top lantern decorative type of capacity 40 watt 360 degree indirect light with IP-65 protection 230 volts complete all as specified and directed by Engr in charge
S&F street light fitting LED 72 watt pressure die cast aluminium housing with heat resistance toughened glass and IP 66 protection luminaries complete all as specified and directed by Engr in charge
S&F 1100 volt grade heavy duty cable PVC insulated round sheathed multistranded copper conductor three core of size 2.5 sqmm for connection of street light fitting from junction box to street light fitting complete all as specified and directed.
S&F AC to DC voltage convertor (230 Volt AC to 28 Volt DC) with input voltage varies from 88-246 Volt with frequency 47-63 Hzs with efficiency 74% with overload protection 110 to 150% rated out put and output voltage adjustable range 22.8 to 26.4 Volt with rated power 108 W and current range 0-4.5A complete all as specified and directed by engr in charge.
M & L for chemical earthing complete with copper earth plate 60x60x3.15 mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of copper strip 20x3 mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 all as directed.
M&L for boring of hole under road, pavement hard standing by trenchless technology using ultra sounding techinque and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by engr in charge.
EXTERNAL WATER SUPPLY M&L for cutting the existing 100 mm dia CI pipe & inserting tee of 100x40 mm size including fittings complete all as specified and directed by Engr in charge.
M&L for Construction of valve pit chamber of size 900 X 900 X 900 mm ( inner dimension) with cover 3 mm thick MS sheet, hinged including angle iron frame handle and locking arrangement and excavation earth work, PCC of 1:3:6 type C1, plastering in cement mortor 1:4 painting to all steel surfaces with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engr in Charge.
M&L for Construction of valve pit chamber of size 600 X 600 X 600 mm ( inner dimension) with cover 3 mm thick MS sheet, hinged including angle iron frame handle and locking arrangement and excavation earth work, PCC of 1:3:6 type C1, plastering in cement mortor 1:4 painting to all steel surfaces with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engr in Charge.
UPS Supply and fix UPS for 30 Min back up three phase AC input 300 V to 450 Volt and output 415 Volt + 1% of capacity 10 KVA complete including battery bank and rack connector complete all as specified and directed.
M & L for earthing complete with copper earth plate electrode 60x60cmx3.15mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of copper earth strip 20x3 mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point terminal block all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 all as directed. (UPS- 2 & LP - 12)
LIGHTNING PROTECTION Supply and fixing of galvanised iron tubular pole SP-76 of size 14.5 mtr long for lightning arrestor including excavation work and foundation complete all as specified and directed by Engr in charge.
AIR CONDITIONING Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minium 5 star rating and minimum EER 3.2 of capacity of capacity 1.5 TR complete all as specified and directed by Engr in charge.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minium 5 star rating and minimum EER 3.2 of capacity of capacity 2.0 TR complete all as specified and directed by Engr in charge.
S&F voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type suitable for voltage range 170 V to 250 V with out 250 Volts with accuracy + 2.5 complete all as specified and directed by Engr in Charge.
S&F voltage stabilizer of capacity 4 KVA for automatic operation, single phase naturally air cooled indoor type suitable for voltage range 170 V to 250 V with out 250 Volts with accuracy + 2.5 complete all as specified and directed by Engr in Charge.
M/S PRASANTA MAHANTA
M/S ALLIED CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .