EE, SWD-I, PHED
33 and 33/1, Chetla Central Road, (2nd Floor), Kolkata 700027
Engagement of resources person for supervising the protocol standard operating procedures technical documentation of laboratory water testing activities
2022_PHED_388993_1
17/2022-2023/EE/SWD-I/WBPHED
Open Tender
CIVIL WORKS
Item Rate
180 days
South 24 Parganas
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,000
5 Nov 2022
8 Jul 2022
18 Jul 2022
8 Jul 2022
16 Jul 2022
8 Jul 2022
Amount
Deputation of resources person for supervision of ISO/IEC 17025:2017 for continuing NABL accreditation (Chemical Testing of potable water) of Dakhin Raipur Water Testing Laboratory under PHE Dte, as per below details: a) Time to time Guidelines for Laboratory Setup (Instrument list,Class/Accuracy & Suppliers Name) and as per requirement of ISO/IEC 17025:2017 b) To conduct in-house Refresher course on ISO/IEC 17025:2017 as per mandatory requirement of NABL. c) To supervise and assist for preparation & record of General Documentation as per mandatory requirement of ISO/IEC 17025:2017 viz. - Reviewing and Up-dating of Quality Manual - Reviewing and Up-dating of Test Procedure d) To supervise and assist for preparation & record of Technical Documentation as per mandatory requirement of ISO/IEC 17025:2017 viz. - Uncertainty re-calculation - Record follow up and update
e) To supervise and assist for Quality Managers Records as per mandatory requirement of ISO/IEC 17025:2017 viz. - Management Review Meeting (MRM) - Internal Audit - Review & Follow-up Intermediate check - Review & Follow-up Inter-laboratory comprising f) To supervise and assist for Document control as per mandatory requirement of ISO/IEC 17025:2017 viz. g) To supervise and assist for the preparation for surveillance internal audit & Non-conformance closing after internal audit as per mandatory requirement of ISO/IEC 17025:2017 viz. h) Any other non-conformance closing related to ISO/IEC 17025:2017 for continuing NABL accreditation (Chemical Testing of potable water)
Calibration of measuring Instruments Traceable to NABL & as per requirements of NABL guideline for the Equipments viz. Spectrophotometer, pH Meter, Turbidity Meter, Oven, Weight Box, Burette, Pipette of different volume, Volumetric Flask of different volurne, Measuring Cylinder of different volume, Thermometer & any other measuring instruments required for calibration as per NABL traceability & conformity
Supply and delivery of various materials
Slit Assay for ICP-OES 7400 of Thermo
Gasket Set spares for ICP-OES Model: 7400 Thermo
Gas Liquid Seperator Top Cap for VGA, for ICP-OES Model: 7400 Thermo
Membrane Dia, 47, PTFE fr GLS, Mk: Thermo
Turbidity Standard 1000 NTU
Turbidity Standard for TB300IR
Fluoride Standard soln. 1.19814.0500
1000ppm, NIST traceable Arsenic Standard solution for AAS, 125 ml
1000ppm, NIST traceable Iron Standard solution for AAS, 125 ml
1000ppm, NIST traceable Manganese Standard solution for AAS, 125 ml
1000ppm, NIST traceable Copper Standard solution for AAS, 125 ml
1000ppm, NIST traceable Zinc Standard solution for AAS, 125 ml
pH buffer -: clear, colourless pH buffer solution tested at 25 deg C and certified by ISO 17025 accreditated test methd, NIST traceable, pH 7.00 +/-0.01 at 25 deg C
pH buffer -: clear, colourless pH buffer solution tested at 25 deg C and certified by ISO 17025 accreditated test methd, NIST traceable, pH 10.00 +/-0.01 at 25 deg C
Conductivity Standrad-25Deg C, Certified by ISO17025 accreditated Test method, NIST traceable, 1413 us/cm at 25 deg C, 500 ml
Mercury Sulfate 1.93220.0251, 250 gm
4-Aminoantipyrine, 25 gm
2-Propanol, 25 lit
Glycerol, 500 ml
2-Propanol, 2.5 lit, HPLC
Ammonia Buffer Solution, 500 ml
Supply and delivery of following spare parts for Atomic Absorption Spectrophotometer (AAS)
a) MFC of VP 100
b) Peristaltic pump
c) Moisture Trap and Oxy trap
d) Picktel tubing
Note : All NIST traceable Standard solution make - Merck/Thermo-Fisher/Inorganic ventures
DULAL MAJUMDAR
SUNANDA ENVIROMENTAL INTERNATIONAL PVT. LTD.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .