| 1 | L1₹3.8 CrAccepted-AOC 184 NEAR GOODWAY TAILORS PRITHVIPURA RASAL ROAD BRIDGE JODHPUR RAJASTHAN 342006 | JODHPUR | RAJASTHAN | 342006 | ₹3.8 Cr | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹3.8 Cr+₹2.5 L (0.66%)Rejected-Finance T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹3.8 Cr+₹2.5 L (0.66%) | L2 | Rejected-Finance L2 BIDDER |
| 3 | L3₹3.9 Cr+₹7.9 L (2.08%)Rejected-Finance | ₹3.9 Cr+₹7.9 L (2.08%) | L3 | Rejected-Finance L3 BIDDER |
| 4 | L4₹4.7 Cr+₹95.9 L (25.3%)Rejected-Finance GODREJ GENESIS BUILDING UNIT NO 609 PLOT NO XI 6TH FLOOR BLOCK EP GP SECTOR V SALT LAKE KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹4.7 Cr+₹95.9 L (25.3%) | L4 | Rejected-Finance L4 BIDDER |
Tender Value
₹3.9 Cr
EMD Value
₹7.8 L
Closing Date
9 Nov 2022, 12:00 pmClosed
CGM PPand D
1st floor Bijulee Bhawan, Guwahati-1
Turnkey Construction of 02 Nos of 132kV Railway Traction Bay, one each at 132kV Behiating GSS and 132kV Nazira GSS, AEGCL respectively including Supply of Bay Equipment and line bay materials and associated works etc.
2022_AEGCL_27310_1
AEGCL_BEHIATING_NAZIRA
Open Tender
Electrical Works
Turn-key
210 days
Behiating and Nazira
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
₹7.8 L
13 Jan 2023
11 Oct 2022
10 Nov 2022
12 Oct 2022
9 Nov 2022
19 Oct 2022
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
132 kV Gang operated outdoor SF6 Breakers
SIEMENS made Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS (SIEMENS) at Behiating GSS
Current Transformers (1-phase) with terminal connectors etc. as per specification
132 kV, 400-200/1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase) (Tandem Type)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Isolator Without Earth Switch TANDEM Type
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1' ( 1 Nos.) [ 2317.41 Kg/ per Column ]
Column Type 'C2' ( 4 Nos.) [ 1913.04 Kg/ per Column ]
Beams
Beam Type 'B1' ( 1 No.) [ 751.77 Kg/ per Beam ]
Beam Type 'B2' ( 2 No.) [ 751.77 Kg/ per Beam ]
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String suitable for single bus zebra conductor
10 Disc Tension Insulator String suitable for twin bus zebra conductor
9 Disc Suspension Insulator String suitable for single bus zebra conductor
9 Disc Suspension Insulator String suitable for twin bus zebra conductor
Supply of Earthing System Materials
Main Earh mat (65 x12 mmGI Flat)
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of AC supply Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
Spacer for ACSR Twin Zebra Conductor (for main bus)
T Clamp With Connectors and all hardware fittings sutiable for ACSR Zebra Conductor
T clamp suitable for twin ACSR Zebra conductor and connecting to single ACSR Zebra alongwith all hardware fittings
PG clamp With Connectors and all hardware fittings sutiable for ACSR Zebra Conductor
Supply of ABT meter with cubicle as per specification
Mandatory Spares
For 132 kV SF6 Circuit Breakers
Interrupter
Tripping Coil
Closing Coil
For Control & Relay panels
Over current relay/Earth fault relay
Distance protection Relay
Master Trip Relay
132kV Lightning Arrester
132kV , 400-200/1-1-1 Line CT
132kV, isolator moving and fixed contact
Terminal connectors for 132kV CT
Terminal connectors for 132kV isolator
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String suitable for single bus zebra conductor
10 Disc Tension Insulator String suitable for twin bus zebra conductor
9 Disc Suspension Insulator String suitable for single bus zebra conductor
9 Disc Suspension Insulator String suitable for twin bus zebra conductor
Description of Work / Item(s)
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
132 kV Gang operated outdoor SF6 Breakers
SIEMENS made Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS at Behiating GSS
Current Transformers (1-phase) with terminal connectors etc. as per specification
132 kV, 400-200/1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase) (Tandem Type)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Isolator Without Earth Switch TANDEM Type
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1' ( 1 Nos.) [ 2317.41 Kg/ per Column ]
Column Type 'C2' ( 4 Nos.) [ 1913.04 Kg/ per Column ]
Beams
Beam Type 'B1' ( 1 No.) [ 751.77 Kg/ per Beam ]
Beam Type 'B2' ( 2 No.) [ 751.77 Kg/ per Beam ]
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String suitable for single bus zebra conductor
10 Disc Tension Insulator String suitable for twin bus zebra conductor
9 Disc Suspension Insulator String suitable for single bus zebra conductor
9 Disc Suspension Insulator String suitable for twin bus zebra conductor
Supply of Earthing System Materials
Main Earh mat (65 x12 mmGI Flat)
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of AC supply Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
Spacer for ACSR Twin Zebra Conductor (for main bus)
T Clamp With Connectors and all hardware fittings sutiable for ACSR Zebra Conductor
T clamp suitable for twin ACSR Zebra conductor and connecting to single ACSR Zebra alongwith all hardware fittings
PG clamp With Connectors and all hardware fittings sutiable for ACSR Zebra Conductor
Supply of ABT meter with cubicle as per specification
Mandatory Spares
For 132 kV SF6 Circuit Breakers
Interrupter
Tripping Coil
Closing Coil
For Control & Relay panels
Over current relay/Earth fault relay
Distance protection Relay
Master Trip Relay
132kV Lightning Arrester
132kV , 400-200/1-1-1 Line CT
132kV, isolator moving and fixed contact
Terminal connectors for 132kV CT
Terminal connectors for 132kV isolator
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String suitable for single bus zebra conductor
10 Disc Tension Insulator String suitable for twin bus zebra conductor
9 Disc Suspension Insulator String suitable for single bus zebra conductor
9 Disc Suspension Insulator String suitable for twin bus zebra conductor
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of LT power and control cables as required
132 kV Gang operated SF6 Breakers
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables as required
For 132 kV Feeder compatible with existing SAS (SIEMENS) at Behiating GSS
Erection, testing & commissioning of Current transformers including laying & terminating of control cables as required
132 kV, 400-200/1-1-1 Line CT
Erection, testing & commissioning of Isolators including laying & terminating of LT power and control cables as required
132 kV With Single Earth Switch
132 kV Without Earth Switch
132 kV Without Earth Switch Tandem Type
Erection, testing & commissioning of Lightning Arrester including including laying & terminating of control cables as required
132 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator including including laying & terminating of control cables as required
132 kV Post Insulator
Erection, testing & commissioning of CVT including including laying & terminating of control cables as required
132kV CVT
Erection of Mounting structures for different terminal equipments as required for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Isolator Without Earth Switch Tandem Type
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Erection of Switchyard Lattice Steel Columns
Column Type 'C1' ( 1 Nos.) [ 2317.41 Kg/ per Column ]
Column Type 'C2' ( 4 Nos.) [ 1913.04 Kg/ per Column ]
Erection of Switchyard Lattice Steel Beams
Beam Type 'B1' ( 1 Nos) [ 751.77 Kg/ per Beam ]
Beam Type 'B2' ( 2 Nos) [ 751.77 Kg/ per Beam ]
Integration of Control Relay Panel into the existing Substation Automation System (SAS) of SIEMENS made at 132kV Behiating GSS.
Hoisting of Insulator strings, Stringing of Conductors, GI shield wire etc including supply of disc insulator strings, clamps, GI stranded shield wire, connectors etc. As required for whole scope of works
Providing 80 mm thick 1:4:8 PCC base of switchyard as per specifiction & drawings including supply of all materials.
Providing 100 mm thick graveling of switchyard as per specifiction & drawings including supply of all materials.
Installation of earthing system with GI flats, electrodes etc. For present scope of area
Construction of Cable Trenches including supply of all materials and labour as per specification and drawing
C Type Trench
B Type Trench
Illumination
Design and installation of outdoor illumination system for the 132kV bay area (consisting of minimum 6 Nos. of LED lamps with fittings etc.) as per specification including supply of all materials.
Erection of Bay Marshalling Kiosk as per drawings and specifications including construction of foundation inclusive of supply of all foundation Materials and Labour as directed.
Erection, testing and Commissssioning of ABT Meter as per specification
Description of Work / Item(s)
Amount
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Circuit Breaker (1 Set)
Excavation (16.21 Cum per breaker)
Filling (10.73 Cum per breaker)
Brick Soiling (8 Sq.m per breaker)
Formwork (15.36 Sq.m per breaker)
PCC (0.46 Cum per breaker)
RCC (4.22 Cum per breaker)
Reinforcement (209.75 Kg per breaker)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Current Transformer ( 3 Nos.)
Excavation (4.29 Cum per CT)
Filling (3.48 Cum per CT)
Brick Soiling (1.82 Sq.m per CT)
Formwork (6.56 Sq.m per CT)
PCC (0.10 Cum per CT)
RCC (0.52 Cum per CT)
Reinforcement (86.18 Kg per CT)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV CVT (3 Nos.)
Excavation (4.29 Cum per CVT)
Filling (3.48 Cum per CVT)
Brick Soiling (1.82 Sq.m per CVT)
Formwork (6.56 Sq.m per CVT)
PCC (0.10 Cum per CVT)
RCC (0.52 Cum per CVT)
Reinforcement (86.18 Kg per CVT)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Isolators With/ Without Earth Switch/Tandem ( 3 Sets)
Excavation (25.13 Cum per Isolator)
Filling (20.40 Cum per Isolator)
Brick Soiling (11.81 Sq.m per Isolator)
Formwork (16.11 Sq.m per Isolator)
PCC (0.72 Cum per Isolator)
RCC (2.83 Cum per Isolator)
Reinforcement (246.07 Kg per Isolator)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Lightning Arresters( 3 Nos)
Excavation (3.52 Cum per LA)
Filling (2.75 Cum per LA)
Brick Soiling (1.56 Sq.m per LA)
Formwork (3.88 Sq.m per LA)
PCC (0.08 Cum per LA)
RCC (0.54 Cum per LA)
Reinforcement (46.65 Kg per LA)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Post Insulator ( 11 Nos)
Excavation (3.52 Cum per PI)
Filling (2.75 Cum per PI)
Brick Soiling (1.56 Sq.m per PI)
Formwork (3.88 Sq.m per PI)
PCC (0.08 Cum per PI)
RCC (0.54 Cum per PI)
Reinforcement (46.65 Kg per PI)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Column Type (C1), 1 Nos.)
Excavation (110.55 Cum per Column)
Filling (97.229 Cum per Column)
Brick Soiling (25.5 Sq.m per Column)
Formwork (23.96 Sq.m per Column)
PCC ( 1.79Cum per Column)
RCC (8.59.Cum per Column)
Reinforcement (855.89 Kg per Column)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Column Type (C2), 4 Nos.)
Excavation (110.55 Cum per Column)
Filling (97.229 Cum per Column)
Brick Soiling (25.5 Sq.m per Column)
Formwork (23.96 Sq.m per Column)
PCC ( 1.79Cum per Column)
RCC (8.59.Cum per Column)
Reinforcement (855.89 Kg per Column)
Description of Work / Item(s)
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
132 kV Gang operated outdoor SF6 Breakers
SIEMENS made Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS (SIEMENS) at Gargaon GSS, Nazira
Current Transformers (1-phase) with terminal connectors etc. as per specification
132 kV, 400-200/1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1' ( 2 Nos.) [ 2317.41 Kg/ per Column ]
Beams
Beam Type 'B1' ( 3 Nos.) [ 751.77 Kg/ per Beam ]
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String
9 Disc Suspension Insulator String
Supply of Earthing System Materials
Main Earh mat (65 x12 mmGI Flat)
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of AC supply Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
PG clamp With Connectors and all hardware fittings sutiable for ACSR Panther Conductor
T Clamp With Connectors and all hardware fittings sutiable for ACSR Conductors
Tee connector rigid through type along with all hardware fitting for 132 kV LA and suitable for ACSR Panther Conductor
Tee connector rigid through type along with all hardware fitting for 132 kV CVT and suitable for ACSR Panther Conductor
Supply of ABT meter with cubicle as per specification
Mandatory Spares
For 132 kV SF6 Circuit Breakers
Interrupter
Tripping Coil
Closing Coil
For Control & Relay panels
Over current relay/Earth fault relay
Distance protection Relay
Master Trip Relay
132kV Lightning Arrester
132kV , 400-200/1-1-1 Line CT
132kV, isolator moving and fixed contact
Terminal connectors for 132kV CT
Terminal connectors for 132kV isolator
T Clamp sutiable for single ACSR Panther Conductor
T Clamp sutiable for twin ACSR Panther to Single ACSR Panther Conductor
Supply for "Augmentation of 132kV Main Bus from Single Panther Conductor at 132kV Gargaon GSS"
Supply of ACSR Panther Conductor
Supply of Disc Insulator Strings complete with all hardware fittings, clamps etc.
2x10 Disc(90KN each) Twin Tension Insulator String
2x19 Disc(90KN each) Suspension Insulator String
Supply of Clamps and Connectors
T Clamp sutiable for single ACSR Panther Conductor
T Clamp sutiable for twin Panther to Single ACSR Panther Conductor
Spacer for Panther Conductor
Supply of 132kV Post Insulator suitable for handling Twin ACSR Panther conductor with all clamps, connectors, mounting structures etc as per specification
132 kV Post Insulator
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for 132kV Post Insulator
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1' ( 1 Nos.) [ 2317.41 Kg/ per Column ]
Beams
Beam Type 'B1' ( 1 Nos.) [ 751.77 Kg/ per Beam ]
Description of Work / Item(s)
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
132 kV Gang operated outdoor SF6 Breakers
SIEMENS made Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS (SIEMENS) at Gargaon GSS, Nazira
Current Transformers (1-phase) with terminal connectors etc. as per specification
132 kV, 400-200/1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1' ( 2 Nos.) [ 2317.41 Kg/ per Column ]
Beams
Beam Type 'B1' ( 3 Nos.) [ 751.77 Kg/ per Beam ]
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String
9 Disc Suspension Insulator String
Supply of Earthing System Materials
Main Earh mat (65 x12 mmGI Flat)
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of AC supply Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
PG clamp With Connectors and all hardware fittings sutiable for ACSR Panther Conductor
T Clamp With Connectors and all hardware fittings sutiable for ACSR Conductors
Tee connector rigid through type along with all hardware fitting for 132 kV LA and suitable for ACSR Panther Conductor
Tee connector rigid through type along with all hardware fitting for 132 kV CVT and suitable for ACSR Panther Conductor
Supply of ABT meter with cubicle as per specification
Mandatory Spares
For 132 kV SF6 Circuit Breakers
Interrupter
Tripping Coil
Closing Coil
For Control & Relay panels
Over current relay/Earth fault relay
Distance protection Relay
Master Trip Relay
132kV Lightning Arrester
132kV , 400-200/1-1-1 Line CT
132kV, isolator moving and fixed contact
Terminal connectors for 132kV CT
Terminal connectors for 132kV isolator
T Clamp sutiable for single ACSR Panther Conductor
T Clamp sutiable for twin ACSR Panther to Single ACSR Panther Conductor
Supply for "Augmentation of 132kV Main Bus from Single Panther Conductor at 132kV Gargaon GSS"
Supply of ACSR Panther Conductor
Supply of Disc Insulator Strings complete with all hardware fittings, clamps etc.
2x10 Disc(90KN each) Twin Tension Insulator String
2x19 Disc(90KN each) Suspension Insulator String
Supply of Clamps and Connectors
T Clamp sutiable for single ACSR Panther Conductor
T Clamp sutiable for twin Panther to Single ACSR Panther Conductor
Spacer for Panther Conductor
Supply of 132kV Post Insulator suitable for handling Twin ACSR Panther conductor with all clamps, connectors, mounting structures etc as per specification
132 kV Post Insulator
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for 132kV Post Insulator
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1' ( 1 Nos.) [ 2317.41 Kg/ per Column ]
Beams
Beam Type 'B1' ( 1 Nos.) [ 751.77 Kg/ per Beam ]
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of LT power and control cables as required
132 kV Gang operated SF6 Breakers
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables as required
For 132 kV Feeder compatible with existing SAS (SIEMENS) at Gargaon GSS, Nazira
Erection, testing & commissioning of Current transformers including laying & terminating of control cables as required
132 kV, 400-200/1-1-1 Line CT
Erection, testing & commissioning of Isolators including laying & terminating of LT power and control cables as required
132 kV With Single Earth Switch
132 kV Without Earth Switch
Erection, testing & commissioning of Lightning Arrester including including laying & terminating of control cables as required
132 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator including including laying & terminating of control cables as required
132 kV Post Insulator
Erection, testing & commissioning of CVT including including laying & terminating of control cables as required
132kV CVT
Erection of Mounting structures for different terminal equipments as required for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Erection of Switchyard Lattice Steel Columns
Column Type 'C1' ( 2 Nos.) [ 2317.41 Kg/ per Column ]
Erection of Switchyard Lattice Steel Beams
Beam Type 'B1' ( 3 Nos) [ 751.77 Kg/ per Beam ]
Integration of Control Relay Panel into the existing Substation Automation System (SAS) of SIEMENS made at 132kV Gargaon GSS, Nazira.
Hoisting of Insulator strings, Stringing of Conductors, GI shield wire etc including supply of disc insulator strings, clamps, GI stranded shield wire, connectors etc. As required for whole scope of works
Providing 80 mm thick 1:4:8 PCC base of switchyard as per specifiction & drawings including supply of all materials.
Providing 100 mm thick graveling of switchyard as per specifiction & drawings including supply of all materials.
Installation of earthing system with GI flats, electrodes etc. For present scope of area
Construction of Cable Trenches including supply of all materials and labour as per specification and drawing
D Type Trench
B Type Trench
Illumination
Design and installation of outdoor illumination system for the 132kV bay area (consisting of minimum 6 Nos. of LED lamps with fittings etc.) as per specification including supply of all materials.
Erection of Bay Marshalling Kiosk as per drawings and specifications including construction of foundation inclusive of supply of all foundation Materials and Labour as directed.
Erection, testing and Commissssioning of ABT Meter as per specification
Dismantling, Erection, Testing & Commissioning works for "Augmentation of 132kV Main Bus from Single Panther Conductor at 132kV Gargaon GSS"
Erection, Testing & Commissioning of Post Insulator suitable for handling Twin ACSR Panther conductor including laying & terminating of LT power & control cables as required as per specification
132 kV Post Insulator
Erection of Switchyard Lattice Steel Structures
Erection of Switchyard Lattice Steel Columns
Column Type 'C1' ( 1 Nos.) [ 2317.41 Kg/ per Column ]
Erection of Switchyard Lattice Steel Beams
Beam Type 'B1' ( 1 Nos) [ 751.77 Kg/ per Beam ]
Opening and Lowering of 132kV Main Bus Conductor with Insulator string and opening of jumpering etc not mentioned anywhere for 3 phases also transportation to the store.
Stringing of 132kV Main Bus with Twin ACSR Panther conductor (for 3 phases) including hoisting of insulator strings and required jumpering for the whole scope of work.
Dismantling of existing structures and foundations
Description of Work / Item(s)
Amount
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Circuit Breaker (1 Set)
Excavation (16.21 Cum per breaker)
Filling (10.73 Cum per breaker)
Brick Soiling (8 Sq.m per breaker)
Formwork (15.36 Sq.m per breaker)
PCC (0.46 Cum per breaker)
RCC (4.22 Cum per breaker)
Reinforcement (209.75 Kg per breaker)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Current Transformer ( 3 Nos.)
Excavation (4.29 Cum per CT)
Filling (3.48 Cum per CT)
Brick Soiling (1.82 Sq.m per CT)
Formwork (6.56 Sq.m per CT)
PCC (0.10 Cum per CT)
RCC (0.52 Cum per CT)
Reinforcement (86.18 Kg per CT)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV CVT (3 Nos.)
Excavation (4.29 Cum per CVT)
Filling (3.48 Cum per CVT)
Brick Soiling (1.82 Sq.m per CVT)
Formwork (6.56 Sq.m per CVT)
PCC (0.10 Cum per CVT)
RCC (0.52 Cum per CVT)
Reinforcement (86.18 Kg per CVT)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Isolators With/ Without Earth Switch/Tandem ( 3 Sets)
Excavation (25.13 Cum per Isolator)
Filling (20.40 Cum per Isolator)
Brick Soiling (11.81 Sq.m per Isolator)
Formwork (16.11 Sq.m per Isolator)
PCC (0.72 Cum per Isolator)
RCC (2.83 Cum per Isolator)
Reinforcement (246.07 Kg per Isolator)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Lightning Arresters( 3 Nos)
Excavation (3.52 Cum per LA)
Filling (2.75 Cum per LA)
Brick Soiling (1.56 Sq.m per LA)
Formwork (3.88 Sq.m per LA)
PCC (0.08 Cum per LA)
RCC (0.54 Cum per LA)
Reinforcement (46.65 Kg per LA)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Post Insulator ( 6 Nos)
Excavation (3.52 Cum per PI)
Filling (2.75 Cum per PI)
Brick Soiling (1.56 Sq.m per PI)
Formwork (3.88 Sq.m per PI)
PCC (0.08 Cum per PI)
RCC (0.54 Cum per PI)
Reinforcement (46.65 Kg per PI)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Column Type (C1), 2 Nos.)
Excavation (110.55 Cum per Column)
Filling (97.229 Cum per Column)
Brick Soiling (25.5 Sq.m per Column)
Formwork (23.96 Sq.m per Column)
PCC ( 1.79Cum per Column)
RCC (8.59.Cum per Column)
Reinforcement (855.89 Kg per Column)
Civil works for "Augmentation of 132kV Main Bus from Single Panther Conductor at 132kV Gargaon GSS"
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Post Insulator suitable for handling Twin ACSR Panther conductor ( 2 Nos.)
Excavation (3.52 Cum per PI)
Filling (2.75 Cum per PI)
Brick Soiling (1.56 Sq.m per PI)
Formwork (3.88 Sq.m per PI)
PCC (0.08 Cum per PI)
RCC (0.54 Cum per PI)
Reinforcement (46.65 Kg per PI)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Column Type (C1), 1 Nos.)
Excavation (110.55 Cum per Column)
Filling (97.229 Cum per Column)
Brick Soiling (25.5 Sq.m per Column)
Formwork (23.96 Sq.m per Column)
PCC ( 1.79Cum per Column)
RCC (8.59.Cum per Column)
Reinforcement (855.89 Kg per Column)
T N T Projects Ltd
HI-TECH CORPORATION
ABN Tower and Transmission Private Limited
HI-TECH CORPORATION
T N T Projects Ltd
ABN Tower and Transmission Private Limited
HI-TECH CORPORATION
T N T Projects Ltd
Jayanta Khaund
Jayanta Khaund
T N T Projects Ltd
ABN Tower and Transmission Private Limited
T N T Projects Ltd
HI-TECH CORPORATION
ABN Tower and Transmission Private Limited
T N T Projects Ltd
HI-TECH CORPORATION
ABN Tower and Transmission Private Limited
ABN Tower and Transmission Private Limited
T N T Projects Ltd
Jayanta Khaund
Jayanta Khaund
T N T Projects Ltd
ABN Tower and Transmission Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .