Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | ₹9.0 L | L1 | Accepted-AOC ok |
| 2 | L2₹9.2 L+₹17,796 (1.98%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹9.2 L+₹17,796 (1.98%) | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
2 May 2022, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Repair/maintenance of substation, LT Control panel, LT MCCB, LT feeder pillar box, conventional earthling and connected works at AFS Bihta under GE (AF) Bihta
2022_MES_516506_1
8211/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹20,000
Yes
5 Jul 2022
4 Apr 2022
6 May 2022
4 Apr 2022
2 May 2022
18 Apr 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified.
M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified.
M&L for sand cushioning for cable with river washed sand and pinning to provide required cover as per SSR Part –I complete.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc compete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded aggregate mechanically crushed stone for mass filling in stay pits and pole foundation all as specified.
Dismantling of Old UNSV ACSR conductor of any size/type.
M & L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 volts
Re-stretching existing ACSR conductor on pole and binding conductor on insulator properly using new binding wire/jumper wire complete all as directed at site by Engr-in-Charge. Note:- Each line of conductor shall be measured & paid for separately. Reqd size of insulater shall be issued by Deptt.
Supply & fixing GI tubing light grade, on poles, under floors, road crossing etc all as reqd at site and as directed by Engr-in-Charge. (a) 50 mm bore
(b) 80 mm bore
Material & Labour for jointing testing Indoor/out door type cable termination (heat Shrinkable) jointing kit for 1100 Volts underground XLPE cable of size 25 to 50 Sqmm 3 ½ core including taking out old/unserviceable joints complete all as directed. Make : DENSON/3M/M-seal
Description all as per Srl item 15 here-in-before but for cable of size 70 to 150 Sqmm 3 ½ core Make : DENSON/3M/M-seal
Description all as per Srl item 15 here-in-before but for cable of size 185 to 300 Sqmm 3 ½ core Make : DENSON/3M/M-seal
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts connecting and testing for any size complete as directed (Excavation,earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately)
Supply,Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc including taking down old UNSV cable of any size complete all as directed . (excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately) of following sizes :- (a) Cross sectional area 16 Sqmm 4 core
(b) Cross sectional area 25 Sqmm 4 core
(c) Cross sectional area 70 Sqmm 3 ½ core
(d) Cross sectional area 120 Sqmm 3 ½ core
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel including excavation and earth work, GI pipe medium grade 15 mm bore for protection of GI wire from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded crushed stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm graded crushed stone aggregates, reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1 and testing on completionincludingd taking out the old unserviceable one complete all as specified and directed. Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.Note : Rate for taking down of old unsv earthing upto ground level may also be includ in quoting rate).
M & L GI strip 32mm x 6mm buried in ground including taking out old unserviceable one complete all as specified and directed.
M & L for laying 40mm bore tube ,light grade galvanised with all fittings laid in trenches or fixed to walls complete all as specified and directed.
Supply, and fixsheet metal enclosure for DB s when MCB s to be used TPN, Aluminium bus bar 200 Amps, 4 Way 415 volts double door suitable for 3 phase 4 wire 415 Volt, 50 Hz. The bus bar shall be provide with sufficient holes for distribution of LT supply including provision of aluminium tube terminal etc complete all as specified and as directed
M & L including taking out old UNSV MCCB 125 Amps 415 Volt breaking capacity 16 KA 4 pole all as specified and directed by engineer encharge.
M & L including taking out old UNSV MCCB 100 Amps 415 Volt breaking capacity 16 KA 4 pole all as specified and directed by engineer encharge.
M & L including taking out old UNSV MCB 63 Amps 415 Volt TPN 4 pole all as specified and directed by engineer encharge.
Material & labour for cleaning and removing of rust particle, preparation of surface of panels of any size indoor/outdoor type and painting with two coats of synthetic enamel paint over one coat of red oxide primer by using sprey gun including minor repair of LT door, hinges and locking arrangement by using welding machine/screws as required at site complete all as specified and as directed.
Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction including taking out old UNSV confirming to IS:8623/93 comprising of the following :-
a) Aluminium bus bar 400 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set
b) Incoming MCCB 250 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 No Make:Schneider (Compact CVS) /L&T (d-sine) /Siemens (3VL)
(c) Outgoing MCCB 100 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 4 Nos Make:Schneider (Compact CVS) /L&T (d-sine) /Siemens (3VL)
(f) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three. Make Schneider/L&T/C&S/Legrand
(g) CT Coils of suitable ratio-01 Set.
Note:- (i) The quoted rate shall includes minor items such as cable lugs, steel nuts & bolts, washers, top insulators, sleeves, spreaders, provision of extra holes in bus bar, provision of cable gland etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) The Panel shall be surrounded with 23cm brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed.
S & F Synthetic Insulating Mat of size 2m x 1m x 12mm
Material & labour for aluminium conductor steel reinforced (ACSR) including fixing stretching on poles and proper noseling with binding wire with insulator of any size as required at site complete all as specified and as directed
B.K. ROY & SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .