| Sl No | Description | Qty | Unit | Ravi Electricals L1 | ANNAI ELECTRICALS L2 | T PAULKANNU & CO L3 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End. | 104 | Pts | 3,180 ₹3.3 L | 3,243 ₹3.4 L | 3,306 ₹3.4 L |
| 2.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End). | 40 | Pts | 2,584 ₹1.0 L | 2,635 ₹1.1 L | 2,686 ₹1.1 L |
| 3.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End. | 17 | Pts | 2,186 ₹37,162 | 2,229 ₹37,893 | 2,272 ₹38,624 |
| 4.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End). | 30 | Pts | 2,955 ₹88,650 | 3,014 ₹90,420 | 3,072 ₹92,160 |
| 5.00 | Supply and run of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing PVC rigid pipe with necessary connection complete. | 400 | Mts. | 35 ₹14,000 | 36 ₹14,400 | 37 ₹14,800 |
| 6.00 | Supply and fixing of 4 Feet LED 20 W Fitting with LED 20W tube(HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. | 25 | Nos | 1,089 ₹27,225 | 1,110 ₹27,750 | 1,132 ₹28,300 |
| 7.00 | Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. | 44 | Nos | 1,540 ₹67,760 | 1,571 ₹69,124 | 1,601 ₹70,444 |
| 8.00 | Supply and fixing of 4'20 W LED twin box type fitting complete with 2Nos. 20W LED tubes, with conduit pipe suspension from ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting (Higher End). | 15 | Nos | 1,764 ₹26,460 | 1,799 ₹26,985 | 1,834 ₹27,510 |
| 9.00 | Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. | 8 | Nos | 1,716 ₹13,728 | 1,750 ₹14,000 | 1,784 ₹14,272 |
| 10.00 | Supply and fixing of fancy glass shade and 7W / 9W LED bulb. | 10 | Nos | 350 ₹3,500 | 357 ₹3,570 | 364 ₹3,640 |
Tender Value
₹56 L
EMD Value
₹38,000
Closing Date
30 Sept 2025, 3:00 pmClosed
Superintending Engineer
Office of Superintending Engineer PWD Buildings construction and maintenance circle Madurai
Providing internal and external electrification Minimast and 58 5 KVA Diesel Generator arrangements to Thiru P K Mookiah Thevar Memorial building at Usilampatti in Madurai District
2025_PWD_603067_1
28SE/Bldgs C and M Circle Madurai 2025-26 dated 09.09.2025
Open Tender
Electrical Works
180 days
Usilampatti, Madurai District
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹38,000
15 May 2026
15 Sept 2025
30 Sept 2025
15 Sept 2025
30 Sept 2025
15 Sept 2025
Amount
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End).
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End).
Supply and run of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing PVC rigid pipe with necessary connection complete.
Supply and fixing of 4 Feet LED 20 W Fitting with LED 20W tube(HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting.
Supply and fixing of 4'20 W LED twin box type fitting complete with 2Nos. 20W LED tubes, with conduit pipe suspension from ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting (Higher End).
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of fancy glass shade and 7W / 9W LED bulb.
Supply and fixing of 35 Watts LED Pressure Die-Cast aluminum housing well glass luminaire with 1.5 sq.mm PVC insulated SC unsheathed FRLS copper wire with suitable clamps and necessary connection complete.
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1No.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting.
Supply and fixing of 1200 mm (48") sweep AC Ceiling Fan High Speed complete with 2 module 100W fan step regulator (Higher End) with 1 metre down rod on the existing clamp.
Supply and fixing of 1200 mm (48") sweep AC Ceiling Fan High Speed complete with 2 module 100W fan step regulator (Higher End) with 600mm down rod on the existing clamp.
Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of 6W LED Round type Recessed fitting with LED on false Ceiling from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting.
Supply and fixing of 450mm wall mounting air circulator fan with turbo force with necessary connection complete.
Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 1No. 6/16A two module socket, 1No. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End.
Supply and fixing of 3Nos. 6A two module socket, 1No. 6/16A two module socket, 3Nos. 6A one module switch, 1No. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End.
Supply and fixing of 20A flush type wall socket 32A DP MCB complete set for AC Plug inflush with wall with earth connection.
Supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed FRLS copper leads from SMC box to fitting and with painting of suitable colour.
Supply and fixing of Decorative post top light of IP 65 rating made up of aluminium die cast housing wider light distribution with opal diffuser, uniform and low glare lighting suitable for retrofit LED lamp B22 base, with 1No. 15W LED lamp should be mounted on suitable dia GI pipe (class ‘B’) of 1 Mt. Length which should be grouted on top of the gate pillars and Wiring with 3 x 1.5 Sq.mm PVC insulated SC unsheathed FRLS Cu. Conductor of 1100V grade in suitable GI pipe concealed in the Gate Pillar with one end connected to the 6A SP MCB Control, which should be housed in a fire and shock proof SMC Junction box of size 240 X 130 X 110mm fixed on wall with suitable clamp and 2/4 way connector on suitable hylem sheet with necessary connection complete.
Supply and fixing of 65 mm (21/2") GI pipe (Class 'B')of 6 mt. Length with suitable double arm extended at a angle of 45 degree from the 6Mtr. pole upto 1mtr. of 32mm dia GI Pipe (Class 'B') duly welded with removable top bracket with 300mm x 300mm x 6 mm MS base plate duly welded at the bottom with concreting with construction of Masonary pedestal with SMC box to house 2Nos 6A SP MCB protection control at a height of 2mtrs. above ground level, with door and with lock and key arrangements and with supply and fixing of 2Nos. of 48W LED street light fitting (Higher End) in a Pressure die cast aluminium housing with IP66 protection, with unique peanut lens with choice of optics to ensure uniform distribution, higher spacing between poles and maintenance free system, insect proof heat resistant toughened glass cover with single piece die-cast aluminium housing suitable for 32mm dia, side entry bracket complete pre-wired (which has to be approved by PWD officials) with necessary 3X1Sq.mm PVC unsheathed FRLS Cu. flexible wires (Phase, Neutral and Earthing) with connection complete with painting of suitable colour. Testing and commissioning as directed by the departmental officers.
Coil earth to street light poles with No.8 SWG GI wire of 11.5metres of length in which10metres of total length compressed in to a coil of one meter length (75mm to 100mmdia) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth.
Supply and fixing of 1 No. of 150W LED Flood Light Fitting with integrated driver (Higher End) and surge protection (10KV) with necessary mounting brackets with PVC unsheathed FRLS copper wire and necessary connection complete.
Supply and fixing of 25 litres capacity Automatic Electrical Water Heater with ISI mark (Higher End) with copper container, Glass Wool / Puf Insulation with MS powder coated shell suitable for 230V / 1000W 50 c/s AC supplyon suitable MS clamps with 3 core flex wire but without plumbing work.
Supply and fixing of 8 Way Single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1No. 32A DP MCB switch as incoming and 6Nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 12 Way Single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1No. 32A DP MCB switch as incoming and 10Nos. 6A to 32A SP MCB as outgoing inflush with wall with earth connection only. Higher End.
Supply and fixing of 125A Three phase 500V 4 Pole changeover switch with suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of 32A FP MCB in sheet steel enclosure inflush with wall with earth connection. (The FP MCB & enclosure should be of Higher End).
Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with Earth connection only.
Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB incomer) with double door (metal door) of IP 43 protection with 1 No 125A 4P MCCB as incoming and 5 Nos 63A 3P MCB, 9 Nos 6A to 32A SP MCB as outgoing with suitable cable end box on suitable angle iron frame on wall with earth connection only. Higher End (Generator DB).
Supply and fixing of Vertical type 4 way Triple pole and neutral MCB Distribution board in sheet steel enclosure of double door type with metal door with IP42 protection in sheet steel enclosure with 1 No. of 63A FP MCB as incoming, 63A FP RCCB with 30mA sensitivity (except AC type) and 2Nos. of 32A TP MCB and 6Nos. of 6A to 32A SP MCB as outgoing inflush with wall wall with earth connection only. The MCB DB and MCB's should be of Higher End. (for kitchen and toilet block portion).
Supply and fixing of 6 way 63A 7 segment TPN MCB sheet steel distribution board (Higher end) with metal door cover of IP 42 protection flush type fitted with busbars and neutral links with seperate segment for 4 way provision for accomodating one No 4 pole incoming MCB & another seperate 4 way provision for accomodating one No 4 pole RCCB and seperate 3 segments for provision of sub incomers and seperate 3 segments for single phase MCB outgoings (totally 6 ways in one segment) (3 x 6 ways in outgoing segment- totally 18 Nos) with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only i) 63A FP MCB - 1No as incoming II) 63A DP RCCB with 30mA sensitivity (except AC type) - 3Nos as sub incomers III) 6A to 32A SP MCB as outgoing - 18Nos as outgoings (Lighting).
Supply and fixing of 4 way 63A 7 segment TPN MCB sheet steel distribution board (Higher end) with metal door cover of IP 42 protection flush type fitted with busbars and neutral links with seperate segment for 4 way provision for accomodating one No 4 pole incoming MCB & another seperate 4 way provision for accomodating one No 4 pole RCCB and seperate 3 segments for provision of sub incomers and seperate 3 segments for single phase MCB outgoings (totally 4 ways in one segment) (3 x 4 ways in outgoing segment- totally 12 Nos) with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only i) 63A FP MCB - 1No as incoming II) 63A DP RCCB with 30mA sensitivity (except AC type) - 3Nos as sub incomers III) 6A to 32A SP MCB as outgoing - 12Nos as outgoings.
Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed FRLS copper Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 2.5 Sq.mm (36/0.3) PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 2 of 4 Sq. mm (56/0.3) PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 Sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed FRLS copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 Sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 16 Sq. mm (101/0.45) PVC insulated SC unsheathed FRLS copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 Sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and fixing of Synthetic Moulded Compound Box with 32A Terminal Block with suitable clamps and necessary connection complete.
Supply and fixing of dust and vermin proof cubical type LTCT metering box of size 3ft x 1 ft x 4ft made of 16SWG CRCA sheet steel with door, lock and key arrangement with angle iron support comprising of three compartments for 3 phase energy meter with base plate & view glass arrangements, bus bar arrangements with 1" x 1/4" insulated tinned Copper bus bar for 3phases & neutral with provision for CTs and sealing arrangements as per TNPDCL norms and 3nos 200A (500V) fuse units and MS cable entry box. The earth bus with two runs of 1" x 1/4" tinned copper flat must be run all round the panel to provide double earth connection.The buses should be mounted on the SMC bus insulators with proper spacing and should be provided with heat shrinkable sleeves using RYB & Black colours.The bus bar chamber should be segregated from the adjacent chambers by providing 12mm thick hylem sheet. The panel should be powder coated, the cable size, location etc., should be marked with white paint affixed with Danger sign with 19/16 PVC insulated Cu wire interconnection from meter to fuse unit and necessary connection complete confirming CEIG specifications.
1. 200 A FP switch disconnector fuse units interior only with HRC fuses double break - 1No 2. 125 A TPN switch disconnector fuse units interior only with HRC fuses double break - 1No 3. 100 A TPN switch disconnector fuse units interior only with HRC fuses double break - 3Nos 4. 63A TPN switch disconnector fuse units interior only with HRC fuses double break - 6Nos. In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylem sheet sepearator and properly earthed by tinned solid copper flat as per CEIG specifications. All the doors should be provided with suitable locking arrangement with rubber beedings. The earth bus with two runs of 1" x 1/4" tinned copper flat must be run all round the panel to provide double earth connection. Interconnection of no.8 swg copper conductor from each switch to earth bus shall be connected. The panel should be powder coated, the cable size, capcity of switch, loaction etc., should be superscribed with white paint on each incoming and outgoing switch with metallic danger board shall be affixed complete with mounting on suitable base channel and suitable angle iron frame work support complete (The TPN switches make should be appproved by departmental officers before used on work.)
Supply and fixing of 3 Phase 200A aerial fuse unit for 3 Nos 200A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.
Supply and fixing of 200 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double brEak on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of brass cable gland for 4 x 16 sq.mm PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland for 3 1/2 x 35 sq.mm PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland for 3 1/2 x 70 sq.mm PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland for 3 1/2 x 185 sqmm PVC armoured LTUG cable with earth connection.
Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Laying of 3 1/2 X 35 Sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Laying of 3 1/2 X 70 Sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Laying of 31/2 X 185 Sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clamping of 31/2 X 185 Sq.mm PVC LTUG armoured cable in 65mm Dia Class B GI pipe on post or on wall with suitable MS clamps.
Supply and clamping of 4 x 16 sq.mm Cu. PVC LTUG armoured cable on post or on wall with MS Clamps.
Supply and clamping of 31/2 X 35 Sq.mm PVC LTUG armoured cable on post or on wall with MS Clamps.
Supply and clamping of 31/2 X 70 Sq.mm PVC LTUG armoured cable on post or on wall with MS Clamps.
Supply and providing cable end termination of 3 1/2 x 35 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and providing cable end termination of 3 1/2 x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and providing cable end termination of 31/2 X 185 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Design, Supply, Testing and commissioning of 12 Meter Mini Mast lighting Unit complete with hot dip galvanized and suitable for 45 Mtr / Sec wind Velocity and above. The Mni mast structure should have head frame, single ring and provided with galvanized lantern carriage suitable for 6 Nos. of 150W LED Luminaries with manual ladder arrangement & suitable size weather proof feeder pillar Box with Automatic timer system including wiring etc., complete as specified in the relevant standard. Supply and fixing of specially Heavy type water proof, Dust proof integral luminaries fitting provided with 150W rectangular LED flood light with innovative thermal management and available in multiple optics and equiped with IP 66 protection with control switch gears, Alglas coated reflectors, with cable connection etc., complete as per standard specification.
Supply and fixing of hot dip galvanized lightning arrester and necessary accessories etc., complete as per standard specification. Supply, erection and commissioning of 0.90m x 0.45m x 1.20m floor mounting (feeder pillar Box and sufficient numbers of Ventilation opening should be provided & supporting M.S. angle frame with 32A main switch, 1 No.32A fuse unit 3 Nos. 32A power contactor with Automatic timer arrangement and the feeder pillar Box should be powder coated including all other allied materials etc., Supply and fixing of Aviation Lamp fitting with Base and coupling arrangements etc., complete as per standard Specification.
Supply, Erection, Testing and Commissing of 2.0TR (6000K.cal/hr) ABS plastic split type AC units Conforming to IS.1391(part-2) with amendments up to date fitted with Rotary compressor operating on non-CFC refrigerant suitable for operation on 230V, 50Hz single phase AC supply with star rating of 5 as per BEE specification and capable of performing the funtions of 1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering The installation work for the above split type AC units inculds the following 1. Mounting/fitting indoor and outdoor units at their respective locations. 2. Laying copper refrigerant pipe line of required length and connecting both units after drilling hole/holes in the wall if required. Thickness of the copper tubing shall not be less than 0.8 3. Insulating the suction pipe with expanded polythylene foam 8 mm tubing. 4. Laying 25 mm dia flexible PVC drain pipe to throw out the condensate water being formed with in indoor unit.
5. Leakage testing the entire system gas in the unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sq. mm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit Make and model shall be approved by the departmental officers before used on work.
Supply and installation of 5KVA electronic automatic voltage stabilizer (V-guard make/ Eq) with input volt range 170V-270V and outputvolt range 200V to 240V with high and low voltage cut off 3min time delay relay with demonstration.
Supply and fixing of MS stand for fixing outdoor unit.
Supply and Laying of 5/8" and 3/8" copper pipe (Extra beyond 3 meters supplied with AC unit).
Supply and fixing of 1" PVC water drain pipe line on wall with suitable clamp and insullation as required.
Supply, Testing Commissioning and Handing over of 58.5kVA Diesel Generator set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications with Standard Control Panel of 0.8 P.F. Three phase 415V/ 440 Volts, 50Hz, 1500 RPM CPCB Approved capacity developing 74 HP with acoustic enclosure water cooled clock wise rotating feed pump with 46.8KW/ 58.5KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and standard control panel as detailed below including transporting & unloading charges.
A. Engine Water cooled diesel engine suitable for Generator application conforming CPCBIV+ norms and IS standards with a shaft out put of 74 HP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, air cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc. (B) 12 Volt Electronic starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length (C) Engine Instrument Panel / Mounted: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load.
D)ALTERNATOR: 58.5kVA/46.8kW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to CPCB IV+ Norms. E) STANDARD CONTROL PANEL : The standard control panel (cubical) should be vermin proof and dust proof best quality sheet steel of 16 SWG CRCA MS sheet and floor mounted with suitable hinged glass doors and enamel painted. The panel should be microprocessor based complete with suitable Square/ Rectangular copper bus bars with internal connections and with necessary cables and other accessories and with tapings for the incoming supply from the alternator and for the outgoing supply to the load and incorporating Suitable MCCB and HRC fuses, Set of control fuses, etc. with following facilities.
1. UNDER / OVER LIMIT i. High coolant Temperature ii. Low lube oil pressure iii. Over speed iv. Start fail v. Emergency stop vi. Over load 2. FAULT INDICATIONS: i. LLOP - Low Lub. oil pressure ii. HWT - High water temperature iii. OL - Over load iv. E.STOP - Emergency stop v. DG - Gen set ON vi. LOAD - ON 3.Metering & Protective relaying: i) Multi function Digital panel meter with the functions of Ammeter , Voltmeter, Frequency Meter, Power factor meter, KW meter, KWHr Meter .- 1No 2) Current transformers of suitable ratio. – Set of 3Nos. 3) Earth fault relay – 1No
G. Exhaust Gas Recirculation system arrangements as per CPCB IV+ norms as amended H. BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment. I) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof Acoustic canopy conforming CPCBIV+ norms floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions and compliance to IS standards. Erection of acoustic enclosure suitable for 58.5KVA Diesel generator complete with all accessories as above and suitable supports etc. as approved by competent authority to suit updated CPCB norms.
J) Erection of generator set with proper alignment over the existing foundation. K)Supply of manuals for operation & maintenance of DG set with warranty card etc. L) CEIG approval: Preparation of site plan physical layout, electrical line schematic Diagram 10 sets, getting drawing approval from CEIG preparation of complection report rectification report etc., arranging CEIG inspection and obtaining CEIG safety certificate, payment of CEIG inspection fees if necessary and preparation of one set of approval Drawing and copy of safety certificate in a neat frame work. M)TESTING AND COMMISSIONING After the installation of DG set on its foundation, the DG set should be tested and commissioned with first charging of lubrication oil to its level, first charging of battery and run the set for eight hours on full load test complete. The Genset engine and alternator make should be approved by department officials before used on work.
Earthing as per the ISI specification with an earth electrode of 2.1 metre class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
Supply and fixing of 8W bollard light of IP 65 rating with pressure die cast aluminium material with suitable concrete masonry and necessary connection complete.
Supply and fixing of 3kVA single phase in & single phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1 hour backup along with Powder coated MS Rack and interlink cables with following specifications: 1. Output Voltage Range : 208V/220V/230V/240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : < 10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode
6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action 7. Waveform : Pure sinewave 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery. Make and model of UPS and battery should be approved by the departmental officer before used on work.
ANNAI ELECTRICALS (BID ID -1475295)
T PAULKANNU & CO (BID ID -1475899)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_720892.xls
BOQ • 0.33 MB
formmookaiahthevarmanimadapamelectrical.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid