Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹27.0 L+₹4.2 L (18.2%)Rejected-Finance | L2 | Rejected-Finance BEING L2 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
8 Mar 2021, 6:00 pmClosed
GE AF THANE
The Garrison Engineer (AF) Thane Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR, MAINTAINANCE OF CEILING FAN, EXHAUST FAN, WALL MOUNTED FANSS, PEDESTAL FANS, METER, INTERNAL WIRING, FITTINGS AND FIXTURE ,SERVICE CONNECTION,DISTRIBUTION BOARD,BUILDING SUB MAINS AND ALLIED WORKS AT AFS SITE P UNDER GE AF THANE
2021_MES_417743_1
8992/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹49,000
Yes
30 Jun 2021
1 Feb 2021
10 Mar 2021
1 Feb 2021
8 Mar 2021
24 Feb 2021
1 Feb 2021 - 24 Feb 2021
Amount
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in quoted rate.
Taking down unserviceable main switches and MCB distribution boards single phase ,complete all as specified and as directed by Engr-in-charge
M& L for Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction box 1.2mm thick MS pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 3.15 mm thick bakelite laminated (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC strandedcopper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly ,complete all as specified and as directed by Engr-in-charge .for the following:-
One light point/call bell point/fan point to be controlled by one number one way PT switch
Switch socket combination 5 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 1.5 Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board
All as per item No 3.02 above but on same board
Switch socket combination (multi purposes) 6 Pin 15 Amps point to be controlled by one switch & wiring with 2.5 Sqmm PVC- unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board.
M & L for point wiring with FRLS PVC insulated 1100 Volts grade IS-694 single core multistranded Copper conductor cable 1.5 Sqmm drawn in and including PVC casing capping with accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity copper conductor cable of size 1.5 Sqmm green colour Connected to common earth dolly including pressed mild steel terminal boxes 16 gauge thick of adequate size concealed in wall Covered with 3.15 mm thick bakelite laminated (Hylem/Anchor) for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine steel screws and washers all as specified for the following :-
One Light point/fan point/Bell point controlled by one switch .
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto-All as per item No 4.00 above but for 2.5 Sqmm wire for 15 Amp socket outlet on independent board
One light point controlled by two 2-way switches
S&F switch Piano type single pole one way 5 Amp,230 VAC ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F switch Piano type single pole two way 5 Amp,230 VAC ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
Supply and fixing bell push flush type 5 Amp ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F socket two in one ,3 Pin 5 Amps 230 VAC ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F switch Piano type single pole one way 15 Amp on laminated sheet top cover ,complete all as specified and as directed by Engr-in-charge (Sheet top cover incl in point wiring) .Make: Anchor/Havells/Legrand
S&F socket Pinao type 6 Pin 16 amp,230 VAC ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F bell ding dong AC 230V single pole ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F Ceiling rose, two to three terminals with bakalite 20mm back plate,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F fan regulator electronic socket type 5 speed for ceiling fan 1200/1400 mm sweep ,complete all as specified and as directed by Engr-in-charge . Make: Anchor/Havells/Legrand
Supply & fixing PVC Lamp holder suitable for and including batten fittings ,CFL/Electric lamp with backalite 20mm back plate ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F LED tube rod,environmental friendly energy efficient ready to use 18/20W LED 6000k(4') ,complete all as specified and as directed by Engr-in-charge .Make: Havells/Bajaj/Crompton
S&F Batten for LED tube light fixture with extruded aluminium heat sink,environmental friendly energy efficient ready to use with 18/20W LED 6000K(4') including electric connection with PVC copper flexible three core cable 24/.0076 from ceiling rose to light fitting ,complete all as specified and as directed by Engr-in-charge .Make: Havells/Bajaj/Crompton
S & F ,in repair, modular switch 1 way 6A, 1 module ,complete all as specified and as directed by Engr-in-charge .Make: Legrand, Schneider, SiemensMake: Anchor/Havells/Legrand
S & F ,in repair, Switch piano, flush type, single pole, one way, 5 Amp,240V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, modular switch 1 way 16A, 1 module ,complete all as specified and as directed by Engr-in-charge . Make: Anchor/Havells/Legrand
S & F ,in repair, ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site,complete all as specified and as directed by Engr-in-charge. Make: Anchor/Havells/Legrand
S & F ,in repair, Modular socket 6A/16A-2/3 pin combined 2 modulas flush type 220 V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, capping casing 20mm width ,complete all as specified and as directed by Engr-in-charge
S & F ,in repair, Modular fan regulator Electronics step type 80 watts 2 moduls and connecting ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, fan regulator Electronics step type 80 watts and connecting,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Bell push button flush type 5 Amp,240v ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, and fix bell AC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, and fix bell multi musicAC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Modular switch socket combination 16A,6 pin.3 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, switch socket combination 2 in 1,3 pin,5 and 15 Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, switch socket combination 2 in 1,3 pin,5 Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, switch flame proof rotary type with termination box in LM-6,16A,single pole 250Volt ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, LED lamp 7 watt,220 volt ,complete all as specified and as directed by Engr-in-charge .Make:-Philips,Bajaj,CG
S & F ,in repair, Modular white cover plate with frame suitable for 1 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 2 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 3 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 6 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 8 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 1/2 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 3 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 6 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 8 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
Taking down the ceilling fan with and including cleaning the dust,drit ,greasing,serviceing ,repairing and refixing the original position all as directed. Note:- Necessary spare for repairing will be measured and paid in respective items.
Taking down unserviceable wall mounted fan,exhaust fan of any capacity or size,including cleaning the dust,drit ,greasing,serviceing ,repairing and refixing the original position all as directed. Note:- Necessary spare for repairing will be measured and paid in respective items.
Re winding ceilling fan with super enamelled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep1200 mm ,220 volt ,50 HZ,single phase, complete all as specified and as directed by Engr-in-charge
Re winding exhaust fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep300 mm ,220 volt ,50 HZ,single phase,all as directed
Re winding wall mounted fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep 400/450 mm ,220 volt ,50 HZ,single phase, all as directed
Supply & fixing ceilling fan of size 1200 mm sweep 5 star rating complete all as specified and as directed by Engr-in-charge.Make-Usha/Bajaj/Khaitan
Supply & fixing fresh air fan PVC body of size 300 mm sweep ,complete all as specified and as directed by Engr-in-charge.Make-Bajaj/crompton
Supply only Gun metal bush suitable for particular make of fan of 1200mm sweep ,complete all as specified and as directed by Engr-in-charge
Supply only Gun metal bush suitable for particular make of exhaust fan of 400/450 mm sweep ,complete all as specified and as directed by Engr-in-charge
Supply only ball bearing suitable for particular make of fan of 1200 mm sweep ,complete all as specified and as directed by Engr-in-chargeMake for Bearing Make:- NBC/Tata/SKF
Supply only ball bearing suitable for particular make of exhaust fan of sweep 300mm/450 mm ,complete all as specified and as directed by Engr-in-charge.Make :-SKF/NBC/SKF
Supply only condenser 2.5 Mfd/3.5 Mfd capacity ,complete all as specified and as directed by Engr-in-charge. Make Make :Havells,HPL, Asian.
Supply only Capacitor 4Mfd suitable for exhaust fan of sweep 300mm/450mm ,complete all as specified and as directed by Engr-in-charge.Make :Havells,HPL, Asian.
Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc ,complete all as specified and as directed by Engr-in-charge.
M & L for submain wiring with two runs of single core PVC insulated unsheathed FRLS copper conductor as mentioned below of similar type cable multistranded copper conductor 1100 volts grade IS:694 marked drawn in and including 25mm dia PVC non metallic PVC conduit , medium grade, ISI marked complete with all acessories and fittings laid/fixed concealed in wall/ceiling or surface conduit on wall/ceiling, and connecting to common earth dolly ,complete all as specified and as directed by Engineer-in-Charge. (Note : Cutting chases for counduit and sinking for boxes and making good to walls ,floors etc for sub main wiring will be measured & paid separately in respective items).
Cable of size 6sq mm cable and one Run of 6 sq mm earth continuity conductor
Cable of size 2X4 sq mm and 1X4 sq mm earth continuity conductor
Cable of size 2X10 sq mm and 1X10 sq mm earth continuity conductor
Taking down the unserviceable garden light fitting and supply and fixing garden light post top lanten black painted MS pipe housing with cast aluminium dome shaped threaded top with cylinderical reeded polycarbonate diffuser and accessories with 30 watt LED light ,complete all as specified and as directed by Engineer-in-Charge. Make : Havells /Bajaj/ Philips
M & L for HDPE chamber for earth pit including necessory PCC 1:3:6 type B-2 for fixing the PVC inspection chember of size 200 mm depth, 300mm length and 300mm width ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair,copper strip of 20x3.15 mm as roof conductor and down conductor till test point all as directed by.Note-Copper strip to be jointed through brazzing only ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair, Porcelain insulators of Copper/Aluminium strip on wall / on Roof building with necessary screws washers and nut bolts etc complete all as specified and as directed by Engr-in-charge. Note - Rates are inclusive of copper screws with washers for fixing copper strip on Porcelain insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirement ,complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable and dislocated air termination rod of any type from floor of any size ,complete all as specified and as directed by Engineer-in-Charge.
S&F in repair, of single pointed soild aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor all as specified and directed
Material and labour for earth pit chamber of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chember of size 200 mm depth, 300mm length and 300mm width ,complete all as specified and as directed by Engineer-in-Charge.
M&L for periodical testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal by means of wheat stone bridge method after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete for monthly/Quarterly/Half yearly L2/L3 eqpts/E&M installations/Lightning arresters test ,complete all as specified and as directed by Engineer-in-Charge.
S&F in repair, MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts ,complete all as specified and as directed by Engineer-in-Charge. Make: Havells/Legrand/Benlo
S&F MCB ,SPN 240 volt 32/40 Amp ,complete all as specified and as directed by Engineer-in-Charge. .Make: Havells/Legrand/Benlo
S&F MCB single Pole 240 Volts 6 to 40 Amp ,complete all as specified and as directed by Engineer-in-Charge. .Make: Havells/Legrand/Benlo
M & L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing
Taking down old Unserviceable LT cable of any size ,complete all as specified and as directed by Engr-in-charge.
Supplying and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors/under rods/hard standing/along with poles LT cable XLPE insulated screenecd, PVC bedded, galvanised steel strip or wire armourd electric power cable (heavy duty) 1100 volt, earthed system, grade with aluminium conductor having cross sectional area of the following, complete all as specified and as directed by Engr-in-charge.(Excavation and earth work, sand cushioning & GI pipe shall be measured and paid separately under relevent item of Sch A). Make: Havells/Polycab/Paragon
Of size 35 Sqmm 3.5 core
Of size 25 Sqmm 4 core
Of size 16 Sqmm 4 core
Of size 10 Sqmm 4 core
Of size 6 Sqmm 4 core
M&L for sand cushioning for underground cable using fine sand 8cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and as directed by Engr-in-charge.(Note: Punned thickness shall be considered for payment purpose)
Excavation in trenches, not exc 1.5 mtr wide & not exc 1.5 mtr in depth for pipe line, cable trenches not exc1.5 mtr in depth & getting out in soft/loose soil complete all as specified and as directed by Engr-in-charge
Returning, filling in including spreading leveling, watering and well ramming in layers each not exc 25 cm in soft/loose soil ,complete all as specified and as directed by Engr-in-charge
Removing surplus spoil to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point ,complete all as specified and as directed by Engr-in-charge
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable ,complete all as specified and as directed by Engr-in-charge
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of poles/struts etc,complete all as specified and as directed by Engr-in-charge.
Boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of of 150 mm dia suitable for 0.4 Mpa Working pressure complete all as specified and as directed by Engr-in-charge
Supply and laying GI tubing light grade of 40mm bore for cable protection, complete all as specified and as directed by Engr-in-charge.
S & F of MCB suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA ,63 Amps, complete all as specified and as directed by Engr-in-charge.Make: Havells/HPL/Indoasian
S & F of MCB suitable for 230 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA ,100 Amps complete all as specified and as directed by Engr-in-charge.Make: Havells/HPL/Indoasian
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting TPN 4 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc, complete all as specified and as directed by Engr-in-charge.Make: Havells/HPL/Indoasian
M & L for Sub main wiring with 2 single core 4 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn in existing PVC conduit/casing capping etc with and including independent PVC insulated one run 4 Sqmm single core copper earth wire, complete all as specified and as directed by Engr-in-charge .(Note:- Three lengths of 4 sqmm cable and will be measured as one length). Make: Havells/HPL/Polycab
M & L for Sub main wiring with 2 single core 6 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn in existing PVC conduit/casing capping etc with and including independent PVC insulated one run 6 Sqmm single core copper earth wire, complete all as specified and as directed by Engr-in-charge.(Note:- Three lengths of 6 sqmm cable and will be measured as one length).Make: Havells/HPL/Polycab
Atharva Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .