| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.6 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹27.3 L+₹24,452.30 (0.90%)Rejected-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 2 | Rejected-AOC OTHER THAN L1 | |
| 3 | 3₹28.1 L+₹1.0 L (3.84%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 3 | Rejected-AOC OTHER THAN L1 | |
| 4 | 4₹28.5 L+₹1.4 L (5.13%)Rejected-AOC | 4 | Rejected-AOC OTHER THAN L1 | |
| 5 | 5₹29.3 L+₹2.2 L (8.15%)Rejected-AOC VPO BAILLY TEH DALHOUSIE DISTT CHAMBA HP 176303 | DALHOUSIE | CHAMBA | HIMACHAL PRADESH | 176303 | 5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
12 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL
HEADQUARTERS COMMANDER WORKS ENGINEERS YOL
PROVN OF UNDERGROUND CABLING WITH PANELS AT BAKLOH CANTT
2023_MES_627203_1
CWE/Y-74/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
BAKLOH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) DALHOUSIE
₹74,000
Yes
22 Feb 2024
10 Nov 2023
19 Dec 2023
10 Nov 2023
12 Dec 2023
28 Nov 2023
Amount
Dismantling ACSR or AAC conductor complete of any type and size and removing unservicable conductor from site, complete all as specified.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard and dense soil, complete all as specified and directed.
All as per Srl Item No 2 above but depth exceeding 1.5m but not exc 3.00 metres and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in coping for pole complete all as specified and directed.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 120 sqmm 3.5 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 95 sqmm 3.5 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 70 sqmm 3.5 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 50 sqmm 3.5 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts , grade cross sectional area 25 sqmm 3.5 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables with aluminium conductor, 1100 volts grade cross sectional area 16 sqmm 4 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sqmm 4 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts , grade cross sectional area 10 sqmm 2 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
XLPE LT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts , grade cross sectional area 6 sqmm 2 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
Dismantling and taking out stay assembly complete of any size complete all as specified.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified.
Dismantling insulators any type, any size. complete all as specified.
Taking out old/bent/straight/ tilted LT pole any capacity, any size, any type poles after breaking the PCC complete all as directed.(The rate quoted shall include the cost of excavation,dismantling of conductor, cross-arms and insulators)
Fixing only Steel tubular swagged poles complete with GI base plate, finial taper plug, bolts, nuts and screws specified type 410 SP-31(9 mtrs long) duly painted with aluminium paint two coat over a coat of red oxide, and pasting three layer reflector tape on pole including necessary earth work ,PCC for foundation and PCC for coping as specified and directed by Engr-In-Charge. Note: Steel pole retrieved from above sr item no 20 shall be used )
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including complete all as specified and directed.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and pasting three layer reflector tape upto 1.5 metre height on pole external surface including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC , complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
LED Street light 35W Glass with Lens, 230 V, AC, outdoor type with high pressure die cast aluminum hosing with toughened glass having efficiency (110 Lm/W) and heat resistant complete with driver, lamp with impact and corrosion resistant includng thermal management in multiple optic complete with IP66 protection, complete all as specified. Make:- HPL Cat Part No. HPLLEDSL35CWGLA or its equivalent make in Appendix
GI mounting bracket (suitable for mounting street light) made out of GI light grad tubing of 40 mm dia light grade bend to shape and angle of 120 dgree and having total length not more than 120 cm including fixing clamps, nut and bolts, two coat of aluminium paint complete all as specified and required and as directed.
SMC cable junction box of size 200x140x95mm suitable for street light/PTL, square type , weather proof , IP-54 including fixing of 10Amp MCB SP and clamps , nuts , bolts , washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit with twin core 2.5 Sqmm PVC Cable laying through PVC conduit from junction box to street light fitting complete all as specified and directed. Make : Sintex Cat Part No. GSJB-2014 or its equivalent approved make. Note : Twin Core PVC Cable 2.5 Sqmm from Junction box to Street Light fitting shall be measured under respective item of BOQ.
Twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm with complete cable connection on street light fitting to looping box complete all as specified and directed.
Aluminium strip 25x3.15 mm thick fixed with procelain/PVC saddle and fixing serew etc with minimum twonumber saddles with screws on and including PVC gutties in each one mtr of length for roof conductor and down conductors above ground,fixed in replcement of complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal head screw, fixed in replcement of complete all as specified and directed.
Factory made DB SPN 4 way double door with 200 Amps rated bus bar concealed in wall IP 42/43 protection,240V for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
MCB TPN , 10KA, 415V, 63 amps in the MCB DB including necessary connection complete all as specified and directed.
Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS-H, cable of 2 run 4 Sq mm for phase and neutral and one run of 4 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS-H, cable drawn through PVC Casing Caping/non metallic rigid PVC conduit not less than 20mm dia ISI marked including all conduit and fixing accessories complete. Two runs of cable for phase/neutral, one run of cable for earth and one run PVC conduit will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25X4 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 125 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)
Outgoing:- (a) MCCB having current rating 100 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -06 Nos) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 1 at Chalama Family Qtr Area
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 100 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)
Outgoing:- (a) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -03 Nos) (b) MCCB having current rating 40 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -02 Nos) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 2 at Chalama Family Qtr Area
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 100 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -02 Nos)
Outgoing:- (a) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -04 Nos) (b) MCCB having current rating 40 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 3 at Chalama Family Qtr Area
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 200 Amps with rupturing cap 36 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)
Outgoing:- (a) MCCB having current rating 125 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -04 Nos) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 4 at Chalama Family Qtr Area
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 125 Amps with rupturing cap 36 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)
Outgoing:- (a) MCCB having current rating 100 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -04 Nos) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 5 at Chalama Family Qtr Area
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 200 Amps with rupturing cap 36 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)
Outgoing:- (a) MCCB having current rating 125 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -04 Nos) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 6 at Chalama Family Qtr Area
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 125 Amps with rupturing cap 36 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)
Outgoing:- (a) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -05 Nos) (b) MCCB having current rating 40 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -02 Nos) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 250 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : LT Panel No. 7 at Chalama Family Qtr Area
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 30 of tender doucments.
M/s Shakti Electric Works
M/S SHRI RAM BUILDERS
M/S JATINDERA ENTERPRISES
Havish Construction
RUHI ASSOCIATES
JAI DURGA CONSTRUCTION CO
M/S MALHI CONSTRUCTIONS
M/s. Rishav Sood
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .