| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L1 | Accepted-AOC Being lowest Tenderer | |
| 2 | L2₹29.5 L+₹1.6 L (5.64%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹37.4 L+₹9.5 L (34.1%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8471A REPAIR REPLACEMENT OF FIRE ALARM SYSTEM OF INS ANGRE, INS AGNIBAHU NOORBHOY INWTC GODFREY CLINIC INS KUNJALI ETC UNDER GE NW KUNJALI COLABA MUMBAI
2022_MES_553933_1
8471/A/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹82,000
Yes
3 Feb 2023
23 Sept 2022
15 Oct 2022
26 Sept 2022
13 Oct 2022
29 Sept 2022
23 Sept 2022 - 26 Sept 2022
Amount
Comprehensive monthly maintenance of auto fire alarm systems installed at Outer Area Naval Dockyard including attending of day to day comaplaints. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through skilled technician having 3-5 years experiance and one helper. Daily attendence register and routine maintanence record as per the format approved by Engineer-in-charge shall be prepared/ maintained. Complaints shall be attended on daily basis as recieved and recorded in complaint register. (v) Emergency visit will be carried out when called in addition to the routine monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Material required for replacement will be measured and paid separately under respective items of this schedule as SUPPLY ONLY.
Supplying only of addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC(Above Celling & below celling .) as per tender specificaiton all as specified and directed. Make : Honeywell/Bosch/Morley/Siemens
Supply only conventional type smoke detector with mounting based LED for AFC(Above Celling & below celling .) , complete all as specified.. Make : Edward/GST/Honey well / Morley / Siemens
Supply and fix in replacement addressable Manual call point resettable type complete all as specified. Make : Edward/GST/Honey well/ Morley/Siemens.
Supply and fix in replacement conventional Manual call point resettable type complete all as specified. Make : Edward/GST/Honey well/ Morley/Siemens.
Supply and fix in repairs of hooter with control module.
Supply only addressable/conventional type heat detector with base, rate of temperature rise as per IS-2175 complete all as specified.. Make : Edward/GST/Honey well / Morley / Siemens
Supply only addressable/ conventional Beam master detector with transmitter and receiver complete all as specified. Make : Edward/GST/Honey well / Morley / Siemens
Supply only addressable Fire alarm control panel complying with BSEN54/UL single loop panel of capacity from 126 detectors & 126 modules complete all as specified. Make : Edward/GST/ Honey well/Siemens/AGNI
Supply only addressable Fire alarm control panel complying with BSEN54/UL double loop panel of capacity from 126 detectors & 126 modules complete all as specified. Make : Edward/GST/ Honey well/Siemens/AGNI
Supply only addressable Fire alarm control panel complying with BSEN54/UL four loop panel of capacity from 126 detectors & 126 modules complete all as specified. Make : Edward/GST/ Honey well/Siemens/AGNI
Supply & fix in repairs XX Zone control module (HZM) item suitable for flame detectors Make : Edward/GST/Honey well / Morley / Siemens
Supply and fix in replacement of response indicator (RI) Make: Edward/GST/Honey well / Morley / Siemens
Supply, laying and connecting in replacement of PVC insulated PVC sheathed copper conductor cable size 1.5 sqmm 2 core FRLS 1100 volts drawn in existing MS/PVC conduit fixed on wall/celling of the Bldg complete. Make - Kalinga/ Havells
Supply and fixing MS Conduit of size 20 mm dia including, fixing accessories like saddles, couplers bends tees etc complete all as specified and directed.
Supply only addressable Fire alarm Repeater panel complete all as specified. Make : Edward / GST / Honey well / Siemens
M&L for taking out unserviceable repeater fault control panel of existing fire detector from the existing site and repairing the repeater panel including replacement of unserviceable parts complete and refixing the same in its original position including testing commissioning complete all as specified and directed.
Supply and fix in replacement of PCB loop cord suitable for self addressable fire finder system. Make Edward / GST / Honey well / Siemens.
Supply and fix in replacement of UPS 1.0 KVA suitable for working on 230 Volts, 50 Hz AC supply complete. Make - Microtec/ SuKam
Supply only 12 V 7 AH Battery complete all as specified. Make : Exide /Amaron/Panasonic.
Disconnecting and taking out old unserviceable Mother Board of fire finder system and supply and fixing new mother board for two Nos loops cards suitable for self addressable fire finder. Make: Siemens / Honey well
Material and labour for preperation of steel/iron surface of old painted surface of any Pipeline otherwise described, painting one coat with red oxide zinc chrome paint and 2 coat with anticorrosive paint for protection against sea water (existing pattern) complete all as specified and directed).
Supply, lay/fix, connect and testing MS ERW pipe, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to wall/ceiling or laid in trenches/floors complete all as specified and directed by the Engineer-in-Charge. of following sizes :- Make - TATA, Swastik, Jindal, Prakash, Surya
150 mm bore
100 mm bore
80 mm bore
Factory fabricated MS fire cabinet box as per Existing design made out flat CRCA of appropriate size and thickness 2 mm all as directed including and applying two coats of synthetic enamel paint over a coat of red oxide primer on panel fitted inside bldg on each floor by approved colour & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed.
Supply & fix in repair rubber hose pipe 30 mtr,20mm dia plain 2 ply rayon braided high pressure. Make:-Minimax/Exflame /Cease Fire of ISI Marked.
Supply & fix in repair canvas fire hose 63mm bore 15 m long confirming to IS Having male/female brass coupling both end with winding protection covers (PVC) complete all as specified. Make:-Minimax/Safex/Cease Fire of ISI Marked.
Supply & fix in repair Stainless steel Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified Make:-Exflame Newase /Safex /Cease Fire
Supply & fix in repair hose Reel drum suitable for 30 mtrs X 20 mm dia rubber hose pipe. Make Vijay Engineering/Omex/Cease Fire
Supply & fix in repairs Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle.Make:-Vijay Engineering/Omex/Cease Fire
Supply & fix in repair gun metal Two way fire brigade inlet conection with adaptor OF size 80 mm dia X 63 mm dia.Make:-Vijay Engineering/Omex/Cease Fire
Supply & Fix Fire Hydrant landing valve Type B (double head outlet) of 63 mm dia of size conforming to IS 5290
Supply & Fix Fire Hydrant landing valve Type A (single head outlet) of 63 mm dia of size conforming to IS 5290
Supply & Fix Fire Hydrant stand post 80mm dia GI glanged type 1.5Mtr height with provn of single outlet conforming to IS 908 complte all as directed.
Dismantling and taking out unserviceable Butterfly Valve and material and labor for Butterfly Valve double flanged 80 mm dia. complete including inserting and jointing materials bolts,nut and gasket.
Dismantling and taking out unserviceable sluice valves and material and labor for CI sluice valves double flanged 150mm dia. P.N. 1.6 with chrome steel spindle confirming to IS, complete including inserting and jointing materials bolts,nut and gasket.
Dismantling and taking out unserviceable non-returnable valves and material and labor for CI non-returnable valves double flanged 150mm dia. P.N. 1.6 with chrome steel spindle confirming to IS, complete including inserting and jointing materials bolts,nut and gasket.
ASHOK ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .