Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹27.7 L+₹1.7 L (6.70%)Rejected-Finance | L2 | Rejected-Finance being L2 | |
| 3 | L3₹28.3 L+₹2.4 L (9.07%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L3 | Rejected-Finance being L3 | |
| 4 | L4₹31.6 L+₹5.7 L (21.9%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L4 | Rejected-Finance being L4 |
Tender Value
Refer Docs
EMD Value
₹70,200
Closing Date
19 Sept 2020, 6:00 pmClosed
GARRISON ENGINEER (AF)
Garrison Engineer (AF) Air Force Station Tambaram, Chennai - 600 046
ADDITION ALTERATION TO AFNET SITE 1 POWER ROOM AT BUILDING NO P177 PROVISION OF FENCING AROUND MET SPECIAL REPAIS TO AIR FIELD LIGHTING SYSTEM AND CERTAIN MINOR AND REVENUE WORK AT AF STATION TAMBARAM
2020_MES_370167_1
GE(AF)/TBM/8364/E8
Open Tender
Civil Works
Item Rate
150 days
Air Force Station Tambaram
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (AF)
₹70,200
Yes
14 Oct 2020
18 Aug 2020
21 Sept 2020
18 Aug 2020
19 Sept 2020
5 Sept 2020
19 Aug 2020 - 25 Aug 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out in hard/dense soil complete all as specified and directed
M&L for plain cement concrete, 1:4:8 type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
M&L for brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping and the like etc including necessary formwork
M&L for reinforced cement concrete 1:1.5:3 using 20mm graded stone aggregate as in foundations, including rafts,footings, foundation beams, plinth beams , bases for columns etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter fair finished complete all as specifed and as directed
M&L for reinforced cement concrete 1:2:4 , type B1,using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and as directed
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.fair finished
M&L for reinforced cement concrete 1:1.5:3 type A1 using 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and as directed
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor , roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide ,fair finished complete all as specified and as directed
S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
S&F TMT steel bars 5mm dia and over upto and including 10mm dia , cut to length, bent to shape required, including cranking, bending , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups,spacers and binders
M&L for moorum / red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed
M&L for hardcore with broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed
M&L for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate , 75mm thick as in sub base including necessary formwork complete all as specified and as directed
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregates as in floor , 50mm thick including necessary formwork finished even and smooth complete all as specified and as directed
Returning, filling in hard dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
S&F Firebrick work in linings to fire places, flues, etc. (other than in chimney shafts), set, jointed and pointed in fireclay as in lining of floors, walls and the like etc., complete all as specified and as diretced
Taking down cement plaster on brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
M&L for complete removal of existing treatment of any description from wall and applying 3mm thick wall care putty all as specified and as per Manufacture's instruction
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brickwork/stone masonry or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brickwork/stone masonry or concrete surfaces finished even and smooth complete all as specified and directed
M&L for rendering 5mm thick in cement mortar 1:3 on ceiling finished fair and even complete all as specified
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distember over a coat of primer complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distember over a coat of primer over and including 3mm thick wall care putty on walls complete all as specified and directed
M&L for preparation of new surfaces of ceiling and applying two coat of oil bound distember over a coat of primer including 3mm thick wall care putty on ceiling complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed
M&L for complete removal of existing treatment of external walls and applying one coat of primer and two coats of cement based paint complete all as specified and directed
S&F Powder coated (50micron) aluminium anodised sliding doors fabricated with standard JINDAL or equivalent section of size 63.5mm x 38mm x 1.6mm for frame and section size 47.62 x 44.45 x 1.18mm for vertical style section of size 46.72mm x 44.45mm x 1.18mm for top and central rail section of size 99.25mm x 44.25mm x 1.16mm for bottom rail, section size 19mm x 17.3mm x 0.80mm for glazing clip for shutter including faabrication to required size and partly panelled with and including 12mm thick both side prelaminated particle board and partly glazed with and including 4mm thick plain glass including fitting etc including pivot, handle, mortise lock heavy duty complete all as specified and as directed.Make: Jindal/ Hindalco Note:- Aluminium section of size specified above if not available in the market next immediate higher size of same make shall be provided without any extra cost to the Govt.
S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851mm to 1000 mm in width and of weight between 61 to 80 kg of aluminium (extruded section) body and fixed complete all as specified and as directed
S&F Aluminium anodised window sliding shutter shutters without sash bars using aluminium section of size 45.2mm x 35mm x 1.30mm (for frame, Jindal section No. 20664) and 37.5mm x 15mm x 1.60mm (for shutter, Jindal section No. 20597) of make JINDAL or other equivalent including rubber packing anodised aluminium snap beading etc, and 4mm thick plain glass including necessary locking arrangement and all fittings such as hinges, handles, stays etc, complete all as specified and as directed. Note:- Aluminium section of size specified above if not available in the market next immediate higher size of same make shall be provided without any extra cost to the Govt.
S&F Aluminium anodised grills (Pattern DG-104) bull nosing and polishing of edges 10mm thick with weight not less than 2.5 Kg/sqm for windows, ventilators etc., including 'F' section of size 23.4mm x 15.3mm x 1.4mm thick, joining cleats etc., complete all as specified and as directed
S&F mild steel framed work such as door,gates,grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed
M&L for rendering 10mm thick in cement mortar 1:4 with water proofing compound @ 3% by weight of cement over RCC slab, parapet and the like etc. finished fair and even complete all as specified (Note: WPC shall be measured and paid sepertely under relevant item)
M&L for applying water proofing treatment on horizontal or vertical surfaces by applying oil bound bitumen primer @ 0.20 Kg/sqm and providing 4mm thick APP modified water proofing membarane weighing not less than 4 Kg/sqm reinforced with non-woven polyester matt weighing not less than 160 gm/sqm including minimum 10cm side lap and 15 cm end lap torch sealed and bonded and applying a coat of blown grade hot bitumen 90/15 over and below the membarane @ 1.20 Kg/sqm in drying over the membarane finished with solar reflective bituminous aluminium paint/ primer @ 0.10 Kg/sqm over RCC roof slab/ parapet after cleaning the surfaces by removing dust, dirt etc., as per manufacturers instructions and all as specified and as directed.
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed
M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate , 75mm thick as in plinth protection and the like etc., finished even and smooth without using extra cement complete all as specified and as directed
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed
M&L for reinforced cement concrete 1:1.5:3 type A1 using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed
Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed
M&L for plain cement concrete 1:2:4 type B1, (using 20mm graded stone aggregate) as in ramps, plinth courses and the like etc as directed thickness complete all as specified and as directed
M&L for plain cement concrete 1:2:4 type B2 using 40mm graded stone aggregate as in floor , 100mm thick ,finished fair and even complete all as specified and as directed
M&L for plain cement concrete 1:4:8 type D 2 using 40mm graded stone aggregate , 75mm thick as in sub base and the like complete all as specified and as directed
M&L for screed bed or bedding layer of cement mortar 20 mm thick in cement mortar 1:6 for laying floor finishes etc complete all as specified
S&F Chequered cement concrete tiles of size 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment in floors complete all as specified
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed
S&F Machine pressed rubber moulded precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed
Dismantling posts or struts embedded in concrete, brick work, masonry etc (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to distance of not exceeding 50 meter and making good surfaces.
M&L for Plain cement concrete 1:3:6, type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
M&L for precast cement concrete solid block masonry with cement concrete 1:3:6 type C1 using 20mm graded stone aggregate , exceeding 10 cm in width and setting in mortar 1:6 complete all as specified and as directed
S&F Mild steel hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
S&F mild steel expanded metal not exceeding 4 Kg/sqm, cut to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members comlete all as specified and as directed
Supply only Chain link MS galvanisd fencing, of size and type as specified and as dircted by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed
Removing excavated material to a distance exceeding 250m and not exceeding 500m and depositing where directed at a level not exceeding 1.5 meter complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
S&F Acid resistant vitreous ceramic tiles 15mm thick , unglazed including set, jointed and pointed in chemical resistant mortar, resin type, in floors and laid all as per Manufacture's instruction complete all as specified and as directed
M&L for rendering 10mm thick in cement mortar 1:4 as in backing coat of skirting/dado etc complete all as specified and as direccted
S&F Acid resistant vitreous ceramic tiles 15mm thick , unglazed including set, jointed and pointed in chemical resistant mortar, resin type, as in vertical surfaces such as skirting/ dado etc and fixed all as per Manufacture's instruction complete all as specified and as directed
Taking down shutter of any description not exceeding 2 sqm each and refixing in same opening after make necessary cutting for easing etc. complete all as specified and as directed
M&L for screed bed or bedding layer of cement mortar 15 mm thick in cement mortar 1:6 for laying floor finishes etc complete all as specified
S&F Machine cut kota stone slab flooring 20mm to 25mm thick as in floor laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
S&F Machine cut kota stone slab flooring 20mm to 25mm thick as in vertical surfaces such as riser in steps,skirting,dado etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
S&F Joint free Non - skid coloured ceramic tiles 7mm to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors set and jointed in neat cement slurry and pointed in coloured cement to match with tile complete all as specified and as directed
S&F Joint free Non - skid coloured ceramic tiles 7mm to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in vertical surfaces such as skirting,dado etc set and jointed in neat cement slurry and pointed in coloured cement to match with tile complete all as specified and as directed
M&L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls,built in cement mortar 1:4, complete all as specified and as directed
M&L for preparation of old plastered surface of wall and applying one coat of white wash complete all as specified and as directed
S&F Powder coated (50micron) aluminium anodised doors fabricated with standard JINDAL or equivalent section of size 63.5mm x 38mm x 1.6mm for frame and section size 47.62 x 44.45 x 1.18mm for vertical style section of size 46.72mm x 44.45mm x 1.4mm for top and central rail section of size 99.25mm x 44.25mm x 1.16mm for bottom rail, section size 19mm x 17.3mm x 0.80mm for glazing clip for shutter including faabrication to required size and partly panelled with and including 12mm thick both side prelaminated particle board and partly glazed with and including 5mm thick dark tinted glass including fitting etc including pivot, handle, mortise lock heavy duty complete all as specified and as directed.Make: Jindal/ Hindalco Note:- Aluminium section of size specified above if not available in the market next immediate higher size of same make shall be provided without any extra cost to the Govt.
M&L for preparation of old plastered surface of wall and applying one coat of oil bound distember complete all as specified and as directed
S&F Mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete all as specified and as directed
S&F Mild steel work as in wind ties for roof including securing bolts etc and similar work conforming to Fe-290 Gde E-165
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridges fixed with self tapping screws as specified complete all as specified and as directed
Surface dressing not exceeding 15cm deep in hard /dense soil complete all as specified and as directed
M&L for Firebrick work in linings to fire places, flues, etc., set, jointed and pointed in fireclay all as specified and as directed
M&L for mild steel TMT bars 8mm dia cut to length bent to shape required including cranking bending hooking ends and binding with MS wire (annealed) not less than 0.9mm dia.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor , roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work not exceeding 10cm wide complete all as specified and as directed
M&L for 0.63mm thick mild steel plain black sheet in wall cladding, steel gates, doors etc,cut to size,holes punched , including screws,rivets etc and fixed to wood or steel framing with 40mm laping or welding as required all as specified and as complete all as specified and as directed
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed for the following :-
One light/fan point controlled by one switch.
One 3/5 pin 5 Amps socket outlet on independent board
All as per item No 34 above but for one 3/5 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size FRLS copper cable.
S&F switch piano flush type 5 Amps, Single Pole one way
S&F PVC ceiling rose two to three terminal plate and jumbo type 240 volts
S&F socket outlet 2/3 pin 5 amps 240 volts flush type.
S&F switch socket combination 2 in 1 multipurpose 5/15 amps 240 volts universal type.
S&F LED fitting 4 feet long with light source 18 Watt general purpose and wall mounted led Batten with polycarbonate LED channel & integrated electrinic driver. (Make - Bajaj Cat Part No-BCLSB 18 WH or other equivallent make as approved by GE)
S&F LED Street light 48 Watt made up pressure die cast housing with toughened glass and individual high power LEDs with secondary optics IP66 protection impact resistance of IK07&10KV external SPD complete all as specified. (Make: Havells Cat Pat No-LHETAXU7PA6W048 or other equivallent make as approved by GE)
M&L for sub main wiring 2x6.0 Sqmm single core FRLS PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through with 20mm PVC conduit and conduit accessories fixed surface/concealed with suitable clamps/saddles including one run of 6.0 sqmm FRLS PVC insulated copper cable for continuous earth conductor connected to common earth dolly. Note :- Two runs of 6 sqmm single core multistranded copper conductor and one run for earth continuity conductor and one lenght PVC rigid conduit and its accessories shall be measured as one unit length.
S&F Sheet metal enclosure with distribution board Double Door 230 volts SPN 8 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections all as directed
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed
S&F MCB 6 to 32 Amps, 10 KA , SP 240V, B Curve including connection complete.
S&F isolator SPN 40 amps, 10 KA , 240V, B Curve including connection complete.
S&F isolator TP 100 Amps, 16 KA , 240V ,C Curve including connection complete.
S&F vertical type sheet metal enclosure suitable mounting MCCB as incomer and out going as MCBs TPN 4 ways double door type including 160/163 Amps MCCB, TPN,16 KA, 415V incomer with suitable bus bar including connection complete all as specified and directed .
M&L for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1 cover, 50mm thick ,with 8mm TMT bars 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion
M&L for earthing complete with Copper plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip 20 mm x 3mm size by means of bolts, nuts and washers of copper all as shown in electrical plate No 5 connected to earth test point iincluding necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1 cover, 50mm thick ,with 8mm TMT bars 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion
M&L for maintenance free Chemical earthing consisting of duel pits of minimum 3 metre distance and each pit interconnected with trench of size 1feex1feet (WXD) filled with earth enhancing maintenance free chemical compound of minimum 15Kgs, each pit size 150mm dia x 3m depth consits of copper coated steel rod of size 17.2mm dia of 3m long 250 Microns molecularly bonded, joined with connecting clamps with maintenace free earth eanhancing compounds Curec+ 6 Kgs & Curecon 10 Kgs, compounds strictly be a eco friendly and must comply to IEEE 80:2000 clause 14.5(d), IEEE 80:2000 clause 14.5 (b) and this compound should be electrically and thermally conductive, must be tested for long term in CPRI for at least 2 years to display its stability & compound must be ISO certified, connected with 25x3mm strip and all connected accessories including up to 7.5 mtrs with 25mmx3mm 300mm long copper bus bar fixed as test point on wall with insulator support and pit painted with tested resistance value & the date of test should be mentioned on the name plate. Earth pit should be closed with high density poly ethylene chamber of dimension 308mmX308mmx214mm with locking cover & seal and testing on completion complete all as specified and directed. Make : MEPL/Smart Solutions or other equivallent as approved by GE Note:- Earth value should be less than 1.0 Ohm
S&F copper strip of size 20mm x 3.15mm with insulation saddles and fixing screws etc above roof / wall / pole etc complete all as specified.
Supply,laying, connecting and testing 1100 volts grade, 70 sqmm, 3.5 core, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape complete all as specified.
S&F ceiling fan 1200 mm sweep 230v AC 50 HZ with down rod including connection with suitable size of PVC twisted copper conductor from ceiling rose to fan complete all as specified and directed. (Make : Orient or other equivallent of BAJAJ/HAVELLS/USHA)
Supply and install 1.5 TR capacity split unit indoor/outdoor complete operating on 230 volts, single phase, AC supply with cordless remote control unit and filter configuration with silver iron antibacterial/anti acarile/active carbon/vitamin C/dust filter including copper piping,electrical cabling,drain pipe of suitable size with connected material like fixing bracket complete all as specified and directed. Make:- LG,SAMSUNG,GODREJ,FEEDERS LLOYD
Supply, install, connecting, testing and commissioning of voltage stabiliser for automatic operation of capacity 5KVA naturally air cooled indoor type, single phase, designed for input variation between 170 V to 250 V with output voltage stabilized at 230-250V AC complete all spedifide and directed.
M&L for shifting of Split type air conditioner of capacity up to 1.0 to 2.0 TR carefully by disconnecting all type of connections, clampling, re installation of the same including topping up of refrigerent gas as per the existing level, testing after completion all as specified and directed.
Maintaining complete Air field lighting system consisiting of air field lights,control cables,isolation Transformers,IT chambers,landing Tee,wind sockers etc including other connected works to keep the Air field lighting system in good working condition by providing required numbers of unskilled labour to user's on daily basis all as specified and directed. NOTE: (a) Period /time of working and number of labour required shall be informed by User's at BCR section of Runway well in advance based on ground requirement ,accordingly contractor shall provide the required man power in time. (b) Labours shall be reported to BCR section in time (c) Attendance register duly signed by all concerned including user's shall be produced during payment (d) The rated quoted shall not be less than Minimum wages as notifies by Government of India/ State Government, Local body whichever is higher including all stationery provision such as EPF, ESIC, Bonus, rates etc as applicable.
M/s. V. BAKTHAVATSALAM & CO
RAVI ENTERPRISE
kcs builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .