Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.8 L+₹2.0 L (12.0%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹21.9 L+₹5.2 L (31.0%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
27 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 c/o 56 APO
REPAIR / MAINT OF HT EXTERNAL ELECTRIC, REPLACEMENT OF HT CONDUCTOR, UG CABLES, POLES ETC AT SHARIFABAD AND PATTAN GRN UNDER AGE (I) CIF (K).
2021_MES_484583_1
134 WE-34/2021-22
Open Tender
Civil Works
Item Rate
210 days
Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹41,000
Yes
11 Dec 2021
28 Oct 2021
29 Nov 2021
28 Oct 2021
27 Nov 2021
12 Nov 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc. and getting out in hard / dense soil, complete all as specified and directed.
All as per ser item No 1.00 above but depth exc 1.5 mtr & n exc 3.0 mtr.
Returning, filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exc 25cm thick in any strata, complete all as specified and directed.
Removing excavated soil to a distance not exc 50m, depositing where directed at a level not exc 1.5M above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, complete all as specified and directed. Note : Punned thickness of sand will be measured & paid.
M&L for sub class 'B' brick covering protection to the eletric cable, laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x 180mm x 40mm for protection of HT cabe, laid flat length wise perpendicular to the axis of cable, complete all as specified and directed.
M&L for replacement 80mm bore GI tubing, light grade, fixed to poes/ walls with suitable clamps or laid in trenches/culverts/road crossing,complete all as specified and directed.
All as per ser item No 8.00 above but 100mm bore
All as per ser item No 8.00 above but 150mm bore
M&L for graded coarse aggregate (broken stone or boulders) of size 40-80mm laid in sub-station yard, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in pole coping, bed plates of any description including necessary form work, complete all as specified and directed.
Dismantling of existing old unserviceable ACSR conductor of any size and any descritpions & S&F new ACSR conductors including stringing through existing poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc, complete all as specified and directed. Note : Quoted rates for new aluminium tape / copper binding wire shall be included in the rate.
S&F mild steel cross arms channel, bracing, supports, clamps etc fabricated structured steel, sections including nuts, bolts, washers etc and cutting to required length beat to any shape, drilling holes, fixed on poles or jointed by means of electric welding complete including painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surface & including taking down / dismantling old items, complete all as specified and directed.
Dismantling insulators of any type & size, complete all as specified and directed.
S&F in replacement Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working pressure of size 145mm height, 255mm dia , including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement Pin type porcelain vitreous,brown of white insulator suitable for 11 KV HT of working pressure of size 150mm height, 150mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement Shackle type porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade, complete all as specified and directed.
S&F in replacement shackle type porcelain vitreous brown or white 1100 Volt of size, 150mm dia and 150mm height including GI strap of size of 38 x 5mm insulator bolt of 14mm dia, nuts and washers for working pressure 1100 Vots, complete all as specified and directed.
S&F in replacement Loop type porcelain, vitreous, white brown or green insulator small size,with overall dimensions 65x90mm clearance of hole 16mm, complete all as specified and directed.
S&F in replacement Loop type porcelain, vitreous, white brown or green insulator small size,with overall dimensions 90x140 mm clearance of hole 25.5mm, complete all as specified and directed.
S&F in replacement drop out (DO) fuse unit expulsion type, outdoor, three pole, 200 Amp suitable for HT 11KV, comprising of 6 Nos post insulators, GI steel base mounting frame, GI nut bolts etc with 30A, HT barrel type fuse, complete all as specified and directed.
S&F in replacement transmission class type droup out fuses 11000 volts rating 25-50 Amps, outdoor type, complete all as specified and directed.
Taking down triple pole mechanism complete with DO fuse unit from the site & Supply and Install DO fuse unit triple pole, mechanically operated, mounted on insulator and steel frame with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and air break (switch) insulator suitable for HT 11 KV outdoor type 50 Amps (DO Fuse), complete all as specified and directed. Make : Atlas/ GEC/ Pactil
S&F in replacement lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 65 Kilo Amps, suitable for 11 KV, complete all as specified and directed.
S&F in replacement cable jointing kit for 11KV grade cable for Outdoor termination shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed. Make : 3M/ Birla/ Denson.
All as per item Ser No 26.00 but size of cable 3 core, 120 to 185 sqmm.
S&F in replacement cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed. Make : 3M/ Birla/ Denson.
All as per item Ser No 28.00 but size of cable 3 core, 120 to 185 sqmm.
S&F in replacement cable jointing kit for 11KV grade cable for Straight through joint heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed. Make : 3M/ Birla/ Denson.
All as per item Ser No 30.00 but size of cable 3 core, 120 to 185 sqmm.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm, laid in trenches/ floor/ duct/ fixed on poles/ through GI tubing in different locations/ areas including taking up or down existing, complete all as specified and directed.
All as per item Ser No 32.00 but size of cable 3 core, 120 sqmm.
S&F in replacement mild steel (Fe-410-W(Gde-E-250) quality A) plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, cut to required shape and size for cable duct or any other description, complete all as specified and directed.
Restringing only existing HT 11 KV/ LT OH line/ Jumpers including dismantling of existing old binding wire for tightning, complete all as specified and directed. Note: (a) Restringing of each wire shall be measured and paid accordingly. (b) Binding wire shall be measured and paid separately.
Removing all vegitations, grass, scrubs, creepers and bushes growing in Sub Station yard, around the poles/ stays etc. alongwith fencing by manually/ mechanically and keep the sub station yard neat and clean, complete all as specified and as directed to the satisfaction of Engr-in-Charge. Note :- Unit rate quoted shall be deemed to included to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
Cutting and trimming of tree branches of girth 25mm to 75mm to 3 mtr all around of any size which is obstructing illumination of street light and touching LT/ HT Over head line by using required tools and plants including removing trimmed tree branches, complete all as specified and as directed to the satisfaction of Engr-in-Charge. Note : Each cleaning will be measured and paid separetely
S&F in replacement insulating rubber mat, ISI marked of size 1m x 2m x 19mm thick suitable for 11 KV at MRS & SS 1 OF R & O.
S&F in replacement temperature gauge suitable size for power transformer/ AVR of any capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement PVC sleeves suitable for LT/ HT ACSR conductor/ jumper in any type in RYB Colours superior quality inserted over the existing ACSR, complete all as specified and directed.
M&L for preparation of old surface, cleaning the surface of the steel pole (HT) 11 Mtr long pole structures above the ground level including coping area and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts, , complete all as specified and directed.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT 11KV distribution transformer 100 to 600 KVA including taking up old unservicable transformer oil, complete all as specified and directed.
M&L for conducting oil filtration by stream line/ Vacuum type filter machine to remove the moisture/ carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer including routine testing after filtration for any capacity of transformers/AVR/CT/PT units, complete all as specified and directed. Note : (a) The contractor shall change the filter assy before starting the filtration of transformer / AVR of capacity 600 KVA and more capacities in presence of Engr-in-charge. (b) Necessary documents should be submitted by the contractor to Engr-in-charge
S&F in replacement brass terminal rod with nuts, bolts, washers & bushings suitable for HT side of the transformer of any make and capacity from 100 KVA to 300 KVA, complete all as specified and directed.
All as per srl item No 44.00 above but LT side.
S&F in replacement of brass terminal rod with nuts, bolts & washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 400 KVA, complete all as specified and directed.
All as per srl item No 46.00 above but LT side.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA transformer, complete all as specified and directed.
M&L for prepration the surface dust and oil free and cleaning the bushes the outer surface of the transformer and painting with one coat of weather proof paint, name plate etc, paint free after painting including writing the MES/SM No with white enamelled paint for capacity of transformer 100 KVA to 400 KVA (Indoor/outdoor type), complete all as specified and directed.
M&L for earthing complete with GI earth plate 60x60cmx6mm thick electrode, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnelwiremesh, charcoal dust, 40mm bore light grade protection pipe and salt etc and connected to earthing test point and testing after completion, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4mm earth lead by means of bolts, nuts, check nuts and washers of galvanized steel including GI pipe light grade of size of 20mm bore for protection and GI pipe medium grade 20mm bore for watering funnel with wire mesh, CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 & earth work all as shown in electrical plate No. 3 of SSR Part-I & connected to earthing test point and testing after completion, complete all as specified and directed.
S&F in replacement 11 KV outdoor type gang operated air break switch suitable for horizontal or vertical mounting triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps, complete all as specified and directed.
S&F in replacement lightning arresters expulsion type, complete with all fittings transmission class, discharge capacity 65 Kilo Amps, suitable for 11 KV, complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation and bed plates of electric poles, struts etc including neccessary form work and finished the exposed surface even and smooth without using extra cement and incuding applying two coats of white wash, complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregates) as in foundation etc including neccessary form work, complete all as specified and directed.
S&F anticlimbing device spikes type, fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed.
S&F expulsion fuses Single pole suitable for 11KV, capacity 25 Amps, complete all as specified and directed.
S&F HT danger notice board of size 25 X 20 cm, made out of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps of suitable size, bolts and nuts, complete all as specified and directed.
Dismantling old and unserviceable prestressed concrete/ Steel poles of any type including breaking cement concrete complete & supply and erection of new steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-55 (11mtr long) in truly vertical position 1.5m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts, complete all as specified and directed by engr-in-charge. Note : Earth work and PCC shall be measured and paid seperately )
M&L for stay assembly 20mm dia rod, complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps excavation and concrete measured separately) including dismantling of old one, complete all as specified and directed
Disnmantling of existing old unserviceable earth wire and gradle guard of any size form any position & S&F new GI wire 4mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, complete all as specified and directed
S&F in replacement galvanised stay wire of size 7/4mm, complete all as specified and directed.
M/s Lal Enterprises
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .