AGE (I) Ayodhya
AsstGarrison Engineer (I), Military Engineer Services,Ayodhya Cantt PIN-224001
REP REP MAINT OF UNSV LT FEEDER PILLAR BOX, OCTAGONAL STREET LIGHTS POLES INCL REP OF UNSV ELECTRIC SERVICE CABLES, CONNECTION PLATES, COVER PLATES OF JUNCTION BOX INCL REP OF UNSV XLPE CABLE AND ALLIED WORKS FOR MAP ACCN AREA AT AYODHYA CANTT UN
2026_MES_778955_1
8400/203/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Ayodhya
All as per NIT and Tender Documents.
8 documents required · 8 mandatory
₹500
AGE (I) Ayodhya Cantt
₹80,000
Yes
16 Jul 2026
16 Jul 2026
14 Aug 2026
16 Jul 2026
6 Aug 2026
31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,installing,commissioning and testing in replacement of LT Panel/ LT feeder pillar outdoor type front and rear openable of dimension ( height and length )as per specified by manufacturer and the width/depth for sides of the panel shall not be less than 600 mm ,CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement with angle iron frame of size 50mm x 50mm x 6mm, pedestial type and provided with four Nos of angle iron supports ( size of legs 750mm) duly embedded in foundation by PCC 1:2:4 type B-1 using 20 mm graded stone aggregate and as directed at site fabricated out of 3.15 mm thick CRCA steel sheet with the degree of protection IP-65 and including duly painted powder coated ( 7 Tank Process) and keeping adequate working space inside of the box and double door handle including front mounted cabinet,with locking arrangement wih keys & countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed neoprene rubber gasket around doors as directed before manufacturing the panel including Bus bar compartment duly covered and of following capacity and type with stainless steel nut bolts washers and spares holes with nut bolts on each bus bar and duly covered with shrinkable PVC sleeves as per colour coding ie Red, Yellow, Blue and Black & mounted on DMC / epoxy insulator and making connection of cables with appropriate size of lugs and cable glands and also two No danger Notice plate fixed on panel , two Nos air vent with PVC air pocket filter fixed on sides & The panel shall be prewired with suitable size PVC insulated copper conductor cable not less than 2.5 sqmm, multistranded complete all as specified and directed. | - | - | - | - |
| 2 | The above Panel in item No 1.00 housed with the following switchgears & accessories:-
INCOMING:-
a) Busbar TPN, tinned copper Bus bar electrolytic grade copper rating 1200 Amps , 4 strip covered with colour coded and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators , - 01 Set ( R Y B & N) with nuts bolts & washer for connection
(b) ACB (Air Circuit Breaker), 4 pole, 800 Amp, 415V 50Hz with Microprocessor based MDO, C - power Draw -out ACB, including under voltage/overvoltage & short circuit protection with breaking capacity 50 kA and ICs=100% Icu – 01 No
(c) LED type Phase indicator lamp(RYB) = 03 Nos
d) Ammeter Digital type CT operated, with selector switch and suitable size of CTs -01 Set
e) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 Set
OUTGOING :-
Outgoing Bus bars
a) MCCB 4 pole 400 Amp 50 KA ,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal and magnetic setting with (Ics= 100% Icu) – 01 Nos
(b) MCCB 4 pole 250 Amp 36 KA, 415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 03 Nos
(c) MCCB 4 pole 200 Amp 36 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 03 No
(d) MCCB 4 pole 100 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 03 No | - | Each Job | - | - |
| 3 | Ditto all as above in item No 1.00 above but panel housed and comprised with the following accessories:-
INCOMING:-
a) Busbar TPN, tinned copper Bus bar electrolytic grade copper rating 1200 Amps , 4 strip covered with colour coded and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators , - 01 Set ( R Y B & N) with nuts bolts & washer for connection
(b) ACB (Air Circuit Breaker), 4 pole, 800 Amp, 415V 50Hz with Microprocessor based MDO, C - power Draw -out ACB, including under voltage/overvoltage & short circuit protection with breaking capacity 50 kA and ICs=100% Icu – 01 No
(c) LED type Phase indicator lamp(RYB) = 03 Nos
d) Ammeter Digital type CT operated, with selector switch and suitable size of CTs -01 Set
e) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 Set
OUTGOING :-
Outgoing Busbar connected with
a) MCCB 4 pole 400 Amp 50 KA ,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal and magnetic setting with (Ics= 100% Icu) – 01 Nos
(b) MCCB 4 pole 250 Amp 36 KA, 415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 Nos
(c) MCCB 4 pole 200 Amp 36 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 No
(d) MCCB 4 pole 160 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 No
(e) MCCB 4 pole 100 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 No | - | Each Job | -1.25 | - |
| 4 | Ditto all as above in item No 1.00 above but panel housed and comprised with the following accessories:-
INCOMING:-
a) Busbar TPN, tinned copper Bus bar electrolytic grade copper rating 900 Amps , 4 strip covered with colour coded and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators , - 01 Set ( R Y B & N) with nuts bolts & washer for connection
(b) ACB (Air Circuit Breaker), 4 pole, 630 Amp, 415V 50Hz with Microprocessor based MDO, C - power Draw -out ACB, including under voltage/overvoltage & short circuit protection with breaking capacity 50 kA and ICs=100% Icu – 01 No
(c) LED type Phase indicator lamp(RYB) = 03 Nos
d) Ammeter Digital type CT operated, with selector switch and suitable size of CTs -01 Set
e) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 Set
OUTGOING :-
Outgoing Busbar connected with
a) MCCB 4 pole 400 Amp 50 KA ,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal and magnetic setting with (Ics= 100% Icu) – 01 Nos
(b) MCCB 4 pole 250 Amp 36 KA, 415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 01 Nos
(c) MCCB 4 pole 200 Amp 36 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 No
(d) MCCB 4 pole 160 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 01 No
(e) MCCB 4 pole 100 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 No | - | Each Job | -2.5 | - |
| 5 | Ditto all as above in item No 1.00 above but panel housed and comprised with the following accessories:-
INCOMING:-
a) Busbar TPN, Aluminium, 630 Amps - 01 Set ( R Y B & N) with nuts bolts & washer for connection
(b) MCCB 4 pole 400 Amp 50 KA ,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal & magnetic setting with (Ics= 100% Icu) – 01 No
(c) LED type Phase indicator lamp(RYB) = 03 Nos
d) Ammeter Digital type CT operated, with selector switch and suitable size of CTs -01 Set
e) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 Set
OUTGOING :-
Outgoing Busbar connected with
a) MCCB 4 pole 250 Amp 36 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 Nos
(b) MCCB 4 pole 200 Amp 36 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 Nos
(c) MCCB 4 pole 100 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 01 No | - | Each Job | -3.75 | - |
| 6 | Ditto all as above in item No 1.00 above but panel housed and comprised with the following accessories:-
INCOMING:-
a) Busbar TPN, Aluminium, 400 Amps - 01 Set ( R Y B & N) with nuts bolts & washer for connection
(b) MCCB 4 pole 200 Amp 36 KA ,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal & magnetic setting with (Ics= 100% Icu) – 01 No
(c) LED type Phase indicator lamp(RYB) = 03 Nos
d) Ammeter Digital type CT operated, with selector switch and suitable size of CTs -01 Set
e) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 Set
OUTGOING :-
Outgoing Busbar connected with
a) MCCB 4 pole 100 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 Nos
(b) MCCB 4 pole 63 Amp 16 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 03 Nos | - | Each Job | -5 | - |
| 7 | Ditto all as above in item No 1.00 above but panel housed and comprised with the following accessories:-
INCOMING:-
a) Busbar TPN, Aluminium, 300 Amps - 01 Set ( R Y B & N) with nuts bolts & washer for connection
(b) MCCB 4 pole 160 Amp 25 KA ,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal & magnetic setting with (Ics= 100% Icu) – 01 No
(c) LED type Phase indicator lamp(RYB) = 03 Nos
d) Ammeter Digital type CT operated, with selector switch and suitable size of CTs -01 Set
e) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 Set
OUTGOING :-
Outgoing Busbar connected with
a) MCCB 4 pole 100 Amp 25 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 01 Nos
(b) MCCB 4 pole 63 Amp 16 KA,415 V, 50 Hz alongwith Spreader terminals with adjustable thermal setting with (Ics= 100% Icu) – 02 Nos | - | Each Job | -6.25 | - |
| 8 | M & L in replacement of MS busbar chamber outdoor type fabricated out of 2.00 mm thick CRCA steel sheet of nominal dimension 900 mm x 600 mm x 450 mm duly provided with aluminimum busbar colour coded insulted sleeves (RYBN ) of size 50 mm x 6mm fixed on porcelain insulators ,TPN type 415 Volts , 50 Hz , outdoor weather/vermin proof with both way opening (front & Rear) duly provided with neoprene rubber gasket along the doors openingswith pedestal type duly painted powder coated on CRCA steel sheet encloser complete with grouting of bus bar chamber in ground by using angle iron frame of size 40mm x 40mm x 5mm, (height of legs 600 mm) grouted with PCC (1:2:4) type C-1 with 20mm graded stone aggregate and the bus bar with 04 sets of holes with SS nut bolts & washers all as specified and directed incl making connection /thimbles etc complete. | - | Each | -7.5 | - |
| 9 | Supply and erect in replacement of 6 mtr long Hot dip galvanised octagonal pole with 130mm bottom A/F and 70mm top A/F made up of 3 mm thick HT steel plate having base plate of 220x220x12mm thick alongwith single arm bracket of 1000 mm length made up of 48.3x3.25mm thick plate, 4 Nos M20 x 700 mm GI 'J' type foundation with door opening 0.90 X 350 mm, with bolts,nuts, with template, bakelite sheet box with 01 no 6 A SP MCB and stand type terminal block suitable for 4 core 16 sqmm cable complete. | - | Each | -8.75 | - |
| 10 | M&L for RCC foundation of grade M20 (1 cement : 1.5 sand : 3 stone/brick aggregate) of size 550mm x 550mm x 1400mm out of which 1200mm shall be below F.G.L.(Finished Ground Level) using 4 no. 12mm dia steel reinforcement of grade Fe-415 with 50 mm clear cover to reinforcement and rings using 8mm dia steel reinforcement @ 190 C/C using shuttering, along with supply & installation of 2 nos. of 63mm dia PVC pipe for cable entry and cable exit. 4 no. 'J' type foundation bolts shall be anchored in the foundation (PCD of 205 mm) in such a way that 125mm length of bolt is projected above foundation. It includes water curing as required and soil excavation & backfilling. It also includes supply of all material and labour including erection of foundation at Site complete all as specified and as directed. | - | Each Job | -10 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
BOQ_872469.xls
BOQ • 0.35 MB
TENDERDOCS.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].