Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC LOWEST QUOTED | |
| 2 | L2₹14.6 L+₹72,615 (5.22%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 3 | L3₹16.0 L+₹2.1 L (14.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 4 | L4₹16.4 L+₹2.5 L (17.8%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 5 | L5₹16.8 L+₹2.8 L (20.4%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
5 Oct 2020, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR/REPLACEMENT OF WIRING,LIGHT FITTINGS,MCB,MCCB,DB AND CERTAIN MISC INTERNAL E/M WORKS AT AF STATION UDHAMPUR
2020_MES_375401_1
GE/AFU-40/2020-21
Open Tender
Miscellaneous Works
Item Rate
334 days
AIRFORCE STATION UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF UDHAMPUR
₹70,000
Yes
23 Oct 2020
7 Sept 2020
7 Oct 2020
7 Sept 2020
5 Oct 2020
21 Sept 2020
Amount
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet independent controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Description all as per serial item No.2 here-in-before but in existing concealed conduit.
Description all as per serial item No.3 here-in-before but in existing concealed conduit.
Description all as per serial item No.4 here-in-before but in existing concealed conduit.
Description all as per serial item No.5 here-in-before but in existing concealed conduit.
Switch modular type 6 AMP,one way , one module conforming to IS-3854 complete all as speciifed and as directed
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed.
Socket shuttered outlet 2/3 pin, 6 Amp modular type, 2 modules complete all as specified and as directed.
Socket shuttered outlet 2/3 pin, 6/16 Amp modular type, 2 modules complete all as specified and as directed.
Electric bell, AC 230 volt, single pole, Ding Dong type complete all as specified and as directed.
Modular bell push, single pole one way, 1 module, 6 Amp complete all as specified and as directed.
Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
Modular electronic fan regulator 2 modules rotary step type 230 volts complete all as specified and as directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 6.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 10.00 sqmm main cable and one RM of 10.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 16.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 16.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 16.00 sqmm main cable and one RM of 16.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 6.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 10.00 sqmm main cable and one RM of 10.00 sqmm cable earth wire together shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 16.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 16.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 16.00 sqmm main cable and one RM of 16.00 sqmm cable earth wire together shall be considered as 1 running metre for payment purpose.
Vertical three phase distribution board, TPN, 4 way 440 volts having IP-54 protection, double door with provision for fixing of MCCBs as incomer and MCBs as outgoing complete after taking down existing unservicable main switch, busbar, GI box including accessories therein ,complete all as specified and as directed.Make:CAT PART NO:507680 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein,complete all as specified and as directed. Make:CAT PART NO:507682 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein, complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
S&F in repairs sheet metal enclosure single pole and neutral with earth metal plug and socket complete with one single pole MCB 20 Amps, 230 volts complete all as specified and as directed.
MCCB three pole 415 Volts 50 Hz 100 Amps rating with rupturing capacity not less than 16 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein , complete all as specified and as directed. Make:CAT PART NO:420085 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCCB three pole 415 Volts 50 Hz 63 Amps rating with rupturing capacity not less than 16 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein , complete all as specified and as directed. Make:CAT PART NO:420083 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein , complete all as specified and as directed. Make:CAT PART NO:408618 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB TPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein , complete all as specified and as directed. Make:CAT PART NO:408683 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein, complete all as specified and as directed. Make:CAT PART NO:408620 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB single pole, 16 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein , complete all as specified and as directed. Make:CAT PART NO:408592 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB SP 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein , complete all as specified and as directed. Make:CAT PART NO:408598 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
S&F in repairs integrated LED bulk head luminaire fittings in engineering plastic housing with clear prismatic/opal diffuser/pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage 12 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified.MAKE :CAT Part No:DA11265 of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in repairs indoor decorative extruded aluminium anodised housing/CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink/aluminium housing for excellent heat dissipation; 4 feet (approx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified.. MAKE :CAT Part No:D532065 FOR Batten and rod-P08120 of Wipro or equavalent to Havells/Philips/Crompton Note :- The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in repairs indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified. MAKE :CAT Part No:D531065 of wipro or equavalent to Havells/Philips/Crompton Note :- The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in replacement LED retrofit lamp with maximum wattage 5 watt (lumen output not less than 500 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white, power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 volt to 285 volt AC at 50 Hz, glarefree, 0 UV radiation long life burning hours 50000 hours complete all as specified. (including taking down of existing serviceable/unserviceable lamps and disposing off as directed by Engineer-in-Charge). MAKE :CAT Part No:N50001 of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in replacement LED retrofit lamp with maximum wattage 7 watt (lumen output not less than 700 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation long life burning hours 50000 hours complete all as specified.(including taking down of existing serviceable /unserviceable lamps and disposing off as directed by Engineer-in-Charge). MAKE :CAT Part No:N70001 of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in repairs Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 40 watt to 45 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, surge protection device min 2 KV, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, THD less than 10%, life 50,000 burning hours minimum IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified.MAKE :CAT Part No:D-414065 of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in repairs Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx), maximum system wattage 36 watt (cool white), minimum system lumen output 3000 lumens, CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, surge protection device min 2 KV, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, THD less than 10%, life 50,000 burning hours minimum IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified.MAKE :CAT Part No:CRC010R038HP57GL of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note :- 1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost to the Govt.
Disconnecting & taking up or down existing unserviceable flameproof Point wiring/Rotary Switch/switches/sockets of any description, any size & in any position from existing conduits and making good the disturbed surfaces to match the existing surfaces all as specified and directed.
Flame Proof Point wiring with FRLSH multi stranded flexible copper conductor PVC Insulated fire resistent cable 1.5 Sqmm size, un sheathed cable in including 25 mm size concealed ERW rigid steel conduit ISI marked flame proof wiring with all flame proof steel conduit fitting and accessories ie junction box inner and outer corners inner and outer bends, tees etc complete with flame proof terminals box for mounting switches, sockets, fan regulators, etc. with continuous 1.5 Sqmm PVC insulated fire resistant copper earth cable FRLSH connected to common earth for One light point controlled by one way 5 Amps flame proof switch,complete all as specified and directed .
Flame Proof Point wiring with FRLSH multi stranded flexible copper conductor PVC Insulated fire resistent cable 2.5 Sqmm size, un sheathed cable in including 25 mm size concealed ERW rigid steel conduit ISI marked flame proof wiring with all flame proof steel conduit fitting and accessories ie junction box inner and outer corners inner and outer bends, tees etc complete with flame proof terminals box for mounting switches, sockets, fan regulators, etc. with continuous 4 Sqmm PVC insulated fire resistant copper earth cable FRLSH connected to common earth for 16 A flame proof socket,complete all as specified and directed .
Flame proof rotary switch single pole on and off with cable termination box of 10 Amps rating 230 Volts Class E EX II C suitable for class I Zone I, all as specified. Make :- Sudhir/Shyam/Bajaj/Philips
Flameproof non-intergral wellglass luminaire epoxy finish LM6 aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard and eye bolt 250 Watt incuding all accessories pre wired with polycarbonate cover polyester resin encloser and central locking system, complete all as specified including taking down old. Make :- CAT No SSPL/WG/1234 of Shayam or equivalent in sudhir/Bajaj/Philips Note :- Control gear shall be measured and paid for separately
Flameproof control gear box epoxy finish LM6 aluminium alloy housing including all accessories prewired with polycarbonate cover polyster resin encloser and central locking system, all as specified including taking down old. Make :- CAT No SSPL/MCGB/180 of shyam or equivalent in Sudhir/Philips/Bajaj
Taking down old DB and supply and fixing Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 8 way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (i) MCB SPN 32 Amps with rupturing capacity 16 KA - 06 Nos (ii) MCB SP 06 Amps with rupturing capacity 10KA - 04 Nos Make :- Sudhir or equivalent in shyam/Bajaj/Philips
Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P+earth all as specified. Make :- CAT No SSPL/2C/1010 of shyam or equivalent in Sudhir/Philips/Bajaj
S&F in repair Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 Volts, 2P+earth all as specified. Make :- Sudhir/Shyam/Philips/Bajaj
Taking down unserviceable hanger lights from the hight of approx 10 to 15 mts from ground lavel including electric connections and supply and fixing hangers lights 200 W RADIL LED LH09 Rugged LED mid bay and high bay for varied industrial applications,including necessary electric connection,complete all as specified and directed by Engr-in-charge. CAT No LH09-262-060-50-V6 OF WIPRO or equavalent to Havells /Philips/Crompton
KARAN TRADERS
HIMALAYA ENTERPRISES
RANBIR ENTERPRISES
DAVINDER SINGH
MAHAJAN TRADING CO
M/S Vishwa Mittar Pachyala
R K BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .