| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAdmitted-Finance JHARKHAND | DHANBAD | JHARKHAND | 818142 | ₹4.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.1 Cr+₹12.9 L (3.25%)Admitted-Finance | ₹4.1 Cr+₹12.9 L (3.25%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical KISKO LOHARDAGA | LOHARDAGA | LOHARDAGA | JHARKHAND | - | - | Rejected-Technical NON RESPOSNIVE |
| 4 | Rejected-Technical GIRIDIH | - | - | Rejected-Technical NON RESPONSIVE |
| Sl No | Description | Qty | Unit | SRI NIRMALA EARTH MINERALS PVT LTD L2 | M/S SATYA CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. | 200 | CUM | 139.39 ₹27,878 | 135.39 ₹27,078 Lowest |
| 2.00 | Extra for Earthwork in hard soil as per specification and direction of E/l. | 200 | CUM | 14.24 ₹2,848 | 13.83 ₹2,766 Lowest |
| 3.00 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from Excavation of foundation withing a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 200 | CUM | 50.75 ₹10,150 | 49.3 ₹9,860 Lowest |
| 4.00 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). | 33.55 | CUM | 415 ₹13,923.25 | 403.11 ₹13,524.34 Lowest |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level 1:3:6 (1 Cement : 3 Course sand( zone - III) : 6 graded stone aggregate 20 mm nominal size) | 11.18 | CUM | 3,979.46 ₹44,506.28 | 3,865.49 ₹43,231.64 Lowest |
| 6.00 | Making Plinth protection 50 mm thick of cement concrete1:3:6 (1 Cement : 3 Course sand( zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 234 | SQM | 329.51 ₹77,105.34 | 320.07 ₹74,896.38 Lowest |
| 7.00 | Reinforced cement concrete in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, peirs, abutments, posts & struts etc. above plinth level upto floor five level, excluding the cost of centering and shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 Course sand( zone - III) : 3 graded stone aggregate 20 mm nominal size) | 105.17 | CUM | 5,883.72 ₹6,18,790.83 | 5,715.21 ₹6,01,068.64 Lowest |
| 8.00 | Providing Reinforced cement concrete work in Beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 Course sand( zone - III) : 3 graded stone aggregate 20 mm nominal size) | 612.2 | CUM | 6,084.1 ₹37,24,698.19 | 5,909.85 ₹36,18,021.99 Lowest |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platforms | 3,428.15 | SQM | 403.22 ₹13,82,299.45 | 391.67 ₹13,42,704.29 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressuments and cantilevers | 2,020.9 | SQM | 337.24 ₹6,81,528.99 | 327.58 ₹6,62,007.08 Lowest |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
22 Nov 2022, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya Dhurwa, Ranchi-834004.
Proposed Construction of Balance work of Model School at Boarijor and Sundarpahari in Godda District
2022_JSBCC_62652_1
JSBCCL/123/2022-23
Open Tender
Civil Works - Buildings
Item Rate
270 days
Godda
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹4.1 L
Yes
14 Dec 2022
3 Nov 2022
24 Nov 2022
3 Nov 2022
22 Nov 2022
3 Nov 2022
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
Extra for Earthwork in hard soil as per specification and direction of E/l.
Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from Excavation of foundation withing a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level 1:3:6 (1 Cement : 3 Course sand( zone - III) : 6 graded stone aggregate 20 mm nominal size)
Making Plinth protection 50 mm thick of cement concrete1:3:6 (1 Cement : 3 Course sand( zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Reinforced cement concrete in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, peirs, abutments, posts & struts etc. above plinth level upto floor five level, excluding the cost of centering and shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 Course sand( zone - III) : 3 graded stone aggregate 20 mm nominal size)
Providing Reinforced cement concrete work in Beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 Course sand( zone - III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platforms
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressuments and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, peirs, abutments, posts & struts
Centering and shuttering including strutting, propping etc. and removal of form for Stairs (excluding landings)
Providing designation 75 A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing 125mm thick Reiforcement designation 75 A Brick work in C.M(1:4) in superstructure with approved quality of clean sand of F.M 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer incharge
Providing TOR steel reinforcement of 8mm (TMT Fe 500) dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd, and Vizal Steel)
Providing TOR steel reinforcement of 10 mm (TMT Fe 500) dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd, and Vizal Steel)
Providing TOR steel reinforcement of 12 mm to 32 mm (TMT Fe 500) , 10mm (TMT coil Fe 500), 12mm (TMT coil Fe 500), 16mm (TMT coil Fe 500), 20mm (TMT bar Fe 500), 25mm (TMT bar Fe 500) dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd, and Vizal Steel)
Supplying, fitting, and fixing M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing , properly fabricated with joints continuous fillet welded and finished, carriage of grill to work site, hoisting as per building speficiation and direction of E/I. (where material is not supplied by the deppt.)
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where material is not supplied by the deppt.)
Supplying, fitting, and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10x 2mm at 100mm centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of 'T' iron 40 x 40 x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a apriming coat of red lead paint, carriage, hoisting and taxes all complete as per building specification and direction of E/I
Suppling, fitting, and fixing, 20 gauge G.C.I. sheet gate (Door & Windows) fitted to M.S. angle frame of size 60 x 60 x 6mm, including cost of fabrication, providing necessary locking arrangement with haskal, and domny duty fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per approved drawing, building specifications, and direction of E/I
Providing and laying 25 mm thk. Kota stone slab flooring of approved size, texture and colour over 19 mm thick base of lime mortor (1:1:1) (Lime:putty:surkhy) laid over and joined with grey cement slurry mixed pigment to match with the shade of the slab including rubbing & polishing to granolithic finish with approved quality of carbonandum stone including cost of curing, taxes and rayolty etc. complete as per direction of Engineer-in-Charge. Size 600 x 600 mm
Providing and laying 25 mm thk. Kota stone tiles in riser of stes, skirting of pillars of approved size, texture and colour laid over 12 mm thick cement mortor (1:3) and joined with grey cement slurry mixed pigment to match with the shade of the slab including rubbing & polishing to granolithic finish with approved quality of carbonandum stone including cost of curing, taxes and rayolty etc. complete as per direction of Engineer-in-Charge.
Providing and laying 6 mm precast SEMI GLAZED CREAMIC TILES of approved quality in DADO over 12 mm cement mortar (1:3) and jointed with white cement slurrry flush pointed with white cement including rubbing, polishing and cost of curing taxes and royalty all complete as per building specification and direction of E/I. with commercial grade coloured 15 cm x 15 cm tiles.
Providing and laying vitrified paving/industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size 300 x 300 mm - In toilet floors
Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size 600 x 600 mm
Providing 12 mm Thk. cement plaster(1:4) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12 mm Thk. cement plaster(1:4) on outside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 6mm Thick cement plaster (1:4) in ceiling with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Providing two coats of Oil bound distemper of approved shade and make over a primer coat of washing over new surface (inner walls) including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required, scaffolding, washing of floors, and taxes, all complete as per building specifications and direction of E/I
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade - New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing Primer one coats of Red lead Paint of approved shade and make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales, smoke and grease and cleaning the surface throughly including cost of scaffolding etc. all complete as per building specification dirction of E/I.
Providing two coats of Ready Mixed PAINT of approved shade and make over new steel surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed 110 mm dia pipes.
Providing 25 mm thk. Waterproof cement plaster(1:3) on roof slabs with clean course sand of FM-1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 1.5 mm Thk. Neat cement punning including curing, carriage oe water with all leads and lifts as per building specification and direction of E/I
Providing 250 mm wide Brick Drain in cement mortor (1:6) with ave. 150 mm clear depth and 250 mm appron including cost of earthwork involved with 75 mm, cememt concrete ( 1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in CM (1:3) with punning over exposed surfaces all complete as per building specification dirction of E/I.
Extra for brick work for EACH consecutive floor above first floor including watering and scafolding, all complete as per direction of E/l.
Extra for flooring work for EACH consecutive floor above first floor including watering and scafolding, all complete as per direction of E/l.
Extra for Plaster work over exterior surface for EACH consecutive floor above first floor including cost of scafolding etc all complete as per direction of E/l.
Providing & fixing sheet covering over expansion joints with iron screws as per design - 150 mm wide Non-asbestos fibre cement board 6 mm thick as per IS:14862
Bricks (1K+ 7P = 8 KM.)
Local Sand (3 KM.)
Coarse Sand (10 KM.)
Stone Chips ( 18 KM.)
Stone Metal ( 18 KM.)
Providing and fixing water closet squatting pan (Indian type W.C pan) with 100 mm sand 100 mm sand cost iron P or S trap 10 litre low level white P.C.V flushing cistern with manually control device (handle lever) confirming to IS 7231, Parry ware/Hind ware including cutting and making good the walls and floors where ever required. White Vitreous china orissa pattern W.C pan of size 580x440 mm with integral type foot rests and 10.0 ltr. Low level P.V.C. cistern.
Supplying, fitting and fixing flat back or angular lipped front vitreous white glazed earthern ware urinal of Hindustan "Parry" or any other approved ISS make with 5 ltrs. capacity PVC automatic flushing cistern of hindware or any other ISS approved make with all fittings with C.I. or RS brackets standard size PVC flush pipe with fitting clamps 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 gms. 15mm PVC alkethene pipe 450mm long with brass coupling at both ends and doing plumber points including cutting wall and floor making good the same etc. all complete as per speciifcification and direction of E/I. - Flat back or standing corner (600X350mm)
supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I or M.S bracket 32 mm C.I brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750 mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings : Size 450x300x150 mm
Providing & fixing C.P. brass Bib cock of approved quality confirming to IS 8931, 15 mm dia nominal bore of approved brand for C.P. fittings.
Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I.
15 mm dia.
20 mm dia.
Supplying, fitting and fixing gun metal Non Return valve of approved quality all complete as per specifcation and direction of E/I.
32 mm dia. Wt. not less than 600 gm (Horizontal)
32 mm dia. Wt. not less than 600 gm (Vertical)
Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
32 mm dia. And wt. not less than 700 grams
Providing and fixing Chlorinated Polyvinyl Chloride (cPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
15 mm nominal bore
20 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (cPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. External exposed work
External work exposed on wall - 25 mm nominal bore
External work exposed on wall - 32 mm nominal bore
Making holes in walls for PVC Pipe and restoring the same atfer pipe Laying (b) 250mm thick wall
Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes - 110 mm dia
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Single Tee with door - 110 x 110 x 110 mm
Plain Tee - 110 x 110 x 110 mm
Plain Bend - 110 mm dia
Shoe - 110 mm dia
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. 600 X 450mm
Supplying, fitting and fixing C.P. brass towel rail 20mm X 600mm with bracket container
Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc.
Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Cutting drain width wise above GL for laying PVC pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
Providing and laying NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of (1:2) including testing of joints all complete - 150 mm dia
Supplying, fitting and fixing G.I. Fittings of approved make all complete as per specifcation and direction of E/I.
(A) Elbow
15 mm dia.
20 mm dia.
25 mm dia.
32 mm dia.
(B) Tee - plain
15 mm dia.
20 mm dia.
25 mm dia.
32 mm dia.
(C) Reducing Socket
20 mm dia.
25 mm dia.
(D) Nipple
15 mm dia.
20 mm dia.
(E) Plug
15 mm dia.
20 mm dia.
25 mm dia.
(F) Socket - Plain
15 mm dia.
20 mm dia.
25 mm dia.
(G) Union Socket
15 mm dia.
20 mm dia.
25 mm dia.
(H) Bend with Socket
15 mm dia.
20 mm dia.
25 mm dia.
Construction of 200 x 150 mm dia Deep Bore well complete with 2.0 H.P. submersible pump.
Point wiring in PVC conduit, with Modular type switch:- Wiring for light point/fan point/Exhaust fan point/call bell point with 1.5 Sq.mm F.R P.V.C insulated copper conductor cable in surface / recessed P.V.C conduit as required. with piano type, switch, phenolic laminated sheet with suitable size PVC/M.S. box etc.(Make:- Finolax/Anchor/Polycab)
Group - C
Twin control Point wiring in PVC conduit,with modular type switch:- wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2way piano type switch ,phenolic laminated sheet, suitable size PVC/G.I box etc. as required. (Make:- Finolax/Anchor/Polycab)
Power plug wiring in PVC conduit (2x4 sq. mm):- Wiring for light/power plug with 2 x 4 Sq.mm F.R P.V.C insulated copper conductor single core cable in surface/ recessed P.V.C conduit along with 1 No. 4 Sq.mm F.R PVC insulated copper wire for loop earthing etc as required. (Make:- Finolax/Anchor/Polycab)
Circuit/sub-main wiring in PVC conduit :-Wiring for sub-main wiring with following sizes of P.V.C insulated, copper conductor single core cable in surface/recessed P.V.C conduit as required. (Make:- Finolax/Anchor/Polycab)
a) 2 x 1.5 Sq.mm +1 x 1.5 Sq.earthing
b) 2 x 2.5 Sq.mm +1 x 2.5 Sq.earthing
c) 2 x 6.0 Sq.mm+1 x 6.0 Sq.mm earthing
S/F PVC Conduit: Supplying and fixing of following sizes of med Class PVC conduit of 2 mm thick along with the accessories in surface / recess & cutting the wall and making good the same in case of recessed conduit as required . (Make:- Polycab, Precision, AKG)
Supply and fixing of following size PVC/G.I. box on surface /recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
75mm x 75mm x 50mm deep.
S/F Ceiling Rose:- Supplying & fixing of 2 pin, 5 amp Ceiling rose on the existing junction box/ wooden block including connection etc. as required. (Make:- Anchor, Kona)
S/F Batten / Angle Holder:- Supplying and fixing brass batten/angle holder including connection etc. as required. (Make:- Anchor, Kona)
S/F Call Bell Buzzer:- Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required. (Make:- Anchor, reputed)
Supplying and fixing following Modular type switch/socket on the existing switch box/cover including connection etc.. As required.
5/6 amps. Switch
15/16 amps. Switch
5/6 amps. Socket outlet
6 pin 15/16 socket outlet
Supplying and fixing following Modular type Fan Regulator on the existing switch box/cover including connection etc.. As required.
Supplying and fixing following Modular boxes, bases & cover plate:-
1 or 2 module ( 78 mm x 78 mm x 45 mm)
6 module ( 78 mm x 205 mm x 50 mm)
8/9 module ( 78 mm x 230 mm x 60 mm)
Supplying and fixing following Module G.I. box along boxes, bases & cover plate fo modular switches in recess etc as required :-
1 or 2 module
6 module
8/9 module
S/F MCCB in Panel Board:- Providing and fixing following rating and breaker capacity MCCB with thermomagnetic release and thermal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 25-100 amps, 16 KA fixed thermal setting
S/F SP MCB DB:- Supplying and fixing following way, SP&N MCB doubel distribution board of sheet steel for 240 Volts on surface /recess complete with tinned copper bus bar, neutral busbar, earth bar, detachable gland plate, interconnections, phophatized and powder coated painted including earthing etc. as required ( But without MCB/RCCB/ ISOLATOR). (Make:-SIEMENS-Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU, C & S)
8 Way Double Door
S/F TP MCB DB: - Supplying and fixing following way, horizontal type double door three pole & neutral, sheet steel, MCCB distribution board, 415V, on surface/ recces , complete with tinned copper bus bar, neutral bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCCB/RCCB/Isolator) (Make:-SIEMENS-Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU, C & S)
8 ways (4+24) Double Door. (horizontal type)
Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, 'C' curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( Make:-LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/ L&T- AU VERSION, C & S).
6-32 Amps. Single Pole
6-32 Amps Double Pole
50/63 Amps TPN
G.I. Pipe Earthing:- Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including accessories, and providing massonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal/cock and salt as required.
Supplying and laying of 8 SWG G.I. copper wire at 0.50 meter below ground level for conductor earth electride, including soldering etc. as required.
P/F G.I. lighting conductor finial:- Providing and fixing of Lightning Conductor finial, made of 25 mm dia 300mm ling, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Reverting, Sweating and soldering Lightning Conductor Tape:- Reverting, Sweating and soldering of Copper/G.I. Tape (with another Copper/G.I. tape, base of the finial or any other mettalic obect) as requried.
P/F G.I. lightning conductor tape in horizontal run :- Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for lightning conductor complete as required. (for Horizontal Run).
P/F G.I. lightning conductor tape in Vertical run:- Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for lightning conductor complete as required. (for Vertical Run).
MV Cable Laying up to 35 sq. mm. in ground :- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. direct in ground including excavation, sand cushioning, protective covering by 2nd class bricks and refilling the trench etc as required.
Supply fitting and fixing of PVC/XLPE insulated PVC sheathed heavy duty Al. armoured cable for working voltage up to and including1100 Volts confirming to IS 1554 (part-1) Make:- Havells, KEI, Finolex,Fort Gloster. - 3.5 Core 35 Sq. mm
S.I.T.C. of following rating LED Flood Lighting luminarie with pressure die cast housing and toughened glass cover, IP 66 protection, LUMINOUS EFFICIENCY > 110 LM/W, with lens in existinf pole/pipe for supplly voltage 100-270 V A.C., 50 Hz. Luminaire shall confirm to IS: 10322 part-5/section - 5 and shall be complete with all necessary accessories as required. 50/60 W LED Flood Light
S.I.T.C. of following size ceiling fan 3 Blade confirming to IS: 374:2019including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper wire suitable for 230V 50 Hz- single phase supply etc complete as required. 1200 mm (48") Ceiling Fan
S.I.T.C. of following rating surface mounted LED Tube Light suitable for 230V 50 Hz- single phase supply etc complete as required.
20/22 W LED Tube light
I.T.C. of exhaust fan upto 450 mm sweep in existing opening including making the hole to suit the size of the above fan, making good the damage, connection, commissioning etc as required.
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/ Crompton / GEC/ Havells .
Non Schedule
S.I.T.C. of Main LT Panel Board
Add 18% GST
Add 1% Labour cess 1%
SRI NIRMALA EARTH MINERALS PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .