Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹11.9 L+₹3.3 L (37.7%)Rejected-Finance 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Rejected as stood L2 | |
| 3 | L3₹19.0 L+₹10.3 L (119.0%)Rejected-Finance 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | L3 | Rejected-Finance Rejected as stood L3 |
| Sl No | Description | Qty | Unit | PERFECT IMAGE SOLUTIONS L2 | Computer Gallery L1 | Creative Projects L3 |
|---|---|---|---|---|---|---|
| 1.00 | Day to day preventive & corrective maintenance of the entire Fire Detection system installed at different buildings within the premises Chittaranjan Seva Sadan College of Obstertics,Gynaecology & Child Health Hospitals by engaging 1 no. skilled person in each shift having adequate knowledge and skill in fire detection system as per attached terms & condition. (3shifts) (Rate should be quotated Per Operator/Per Month basis only for this Item.) | 3 | Operators | 25,000 ₹9,00,000 | 16,700 ₹6,01,200 Lowest | 45,000 ₹16,20,000 |
| 2.00Cost for replacement following spare parts (Consumable spares & Emergency spares) as and when required for annual preventive and corrective maintenance of Fire Detection System. (As per attached Annexure I&II) | ||||||
| 2.01 | Supply, Installation, Testing & Commissioning analog Addressable Intelligent multi sensor detector (VDS/UL/FM/ULC aproved) with inbuilt optical smok sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable photo thermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard (Make:Siemens). | 20 | Nos | 4,500 ₹90,000 | 4,000 ₹80,000 Lowest | 4,250 ₹85,000 |
| 2.02 | Supply, Installation, Testing & Commissioning Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard (Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make:Siemens). | 20 | Nos | 4,500 ₹90,000 | 4,000 ₹80,000 Lowest | 4,250 ₹85,000 |
| 2.03 | Supply, Installation, Testing & Commissioning Addressable Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Make:Siemens). | 2 | Nos. | 12,000 ₹24,000 Lowest | 13,000 ₹26,000 | 12,000 ₹24,000 Lowest |
| 2.04 | Supply, Installation, Testing & Commissioning Addressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Make:Siemens). | 10 | Nos | 6,000 ₹60,000 Lowest | 6,000 ₹60,000 Lowest | 6,000 ₹60,000 Lowest |
| 2.05 | Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Make:Siemens). | 20 | Nos. | 250 ₹5,000 | 80 ₹1,600 Lowest | 250 ₹5,000 |
| 3.00 | S & F of MCP Glass in place of damaged one. | 50 | Nos. | 110 ₹5,500 | 20 ₹1,000 Lowest | 50 ₹2,500 |
| 4.00 | S &F UPS Battery,12Volt,12AH SMF (Exide) | 2 | Each | 4,000 ₹8,000 | 3,700 ₹7,400 Lowest | 3,800 ₹7,600 |
| 5.00 | Supply & Laying of 2 core 1.5 sq.mm FRLS shielded copper cable (for loop) (make: Finolex/Gloster/Polycab) | 100 | Mtrs | 100 ₹10,000 | 90 ₹9,000 | 80 ₹8,000 Lowest |
Tender Value
₹8.7 L
EMD Value
₹17,340
Closing Date
5 Jun 2025, 12:00 pmClosed
Exe. Engr.-II, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Annual maintenance contract of Fire Detection System installed at different buildings in the campus of Chittaranjan Seva Sadan College of Obstetrics Gynecology and Child Health, Kolkata under South Kolkata Health Electrical Sub-Division - II, P.W.Dte
2025_WBPWD_850892_1
WBPWD/EE-II/KSHED/Q17/25-26
Open Tender
FIRE FIGHTING M/R
Item Rate
365 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,340
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
8 Sept 2026
22 May 2025
9 Jun 2025
22 May 2025
5 Jun 2025
29 May 2025
28 May 2025
Amount
Day to day preventive & corrective maintenance of the entire Fire Detection system installed at different buildings within the premises Chittaranjan Seva Sadan College of Obstertics,Gynaecology & Child Health Hospitals by engaging 1 no. skilled person in each shift having adequate knowledge and skill in fire detection system as per attached terms & condition. (3shifts) (Rate should be quotated Per Operator/Per Month basis only for this Item.)
Cost for replacement following spare parts (Consumable spares & Emergency spares) as and when required for annual preventive and corrective maintenance of Fire Detection System. (As per attached Annexure I&II)
Supply, Installation, Testing & Commissioning analog Addressable Intelligent multi sensor detector (VDS/UL/FM/ULC aproved) with inbuilt optical smok sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable photo thermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard (Make:Siemens).
Supply, Installation, Testing & Commissioning Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard (Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make:Siemens).
Supply, Installation, Testing & Commissioning Addressable Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Make:Siemens).
Supply, Installation, Testing & Commissioning Addressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Make:Siemens).
Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Make:Siemens).
S & F of MCP Glass in place of damaged one.
S &F UPS Battery,12Volt,12AH SMF (Exide)
Supply & Laying of 2 core 1.5 sq.mm FRLS shielded copper cable (for loop) (make: Finolex/Gloster/Polycab)
Rate should be quotated inclusive of LWC and all other related related taxes & duties
PERFECT IMAGE SOLUTIONS (BID ID -6499989)
Creative Projects (BID ID -6512935)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .